Technical data, application notes, wiring

PS2001-2440-0000

22

Version: 1.0

4.16

EMC

The EMC behavior of the device is designed for applications in industrial environments as well as residential,
commercial or small business environments.

The device was tested according to EN 61000-6-1, EN 61000-6-2, EN 61000-6-3 and EN 61000-6-4.

This device meets the requirements according to FCC Part 15. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must be able to deal with
any interference received, including interference that may cause undesired operation.
The signal cables ("Ready", "Active" and "Inhibit") must be shorter than 30 m.

EMC interference immunity

Fast transients (burst)

EN 61000-4-4

• Input cables

• Output cables

• Signal cables 

Pin 6, 7, 8, 9 

**)

Criterion A

*)

2 kV

**)

 Tested with connecting terminal.

*)

 A: Buffer module exhibits normal operating behavior within the defined limits.

EMC interference emission

For standby and charging mode

Conducted interference emission, input lines

IEC/CISPR 16-1-2,
IEC/CISPR 16-2-1

Limit values for DC power supply connections accord-
ing to EN 61000-6-3 fulfilled

Interference emission

EN 55011, 
EN 55022

Class B

Switching frequencies

Charge converter on 24 V input (is only ac-
tive during charging)

6 to 610 kHz

The frequency depends on the charge state of the ca-
pacitors

Buffer converter when buffering at 22.5 V

10 to 70 kHz

The frequency depends on the output current. The val-
ues are valid between 10% and 100% of the nominal
buffer current

4.17

Environment

Environment

Operating temperature

-25 °C to + 70 °C

The operating temperature corresponds to the ambient or environ-
mental temperature and is defined as the air temperature 2 cm be-
low the device.

Storage temperature

-40 °C to + 70 °C

For storage and transport

Moisture

5 to 95% r.h.

IEC 60068-2-30

Oscillation, sinusoidal

2–17.8 Hz: ±1.6 mm;
17.8–500Hz: 2g 
2 hours/axis

IEC 60068-2-6

Oscillation, any

0.5 m²(s³)
2 hours / axis

IEC 60068-2-64

Impact

30g 6ms, 20g 11ms
3 impacts/direction,
18 impacts in total

IEC 60068-2-27

Installation altitude

0 to 6000m

Approvals apply only up to 2000 m

Overvoltage category

III

IEC 62103, EN 62477-1

II

IEC 62103, EN 62477-1, above an altitude of 2000 m

Degree of pollution

2

IEC 62103, EN 62477-1, not conductive

LABS compatibility

The device does not release any silicone or other LABS-critical substances and is suitable for use
in painting plants.

Summary of Contents for PS2001-2440-0000

Page 1: ...Documentation EN PS2001 2440 0000 Buffer Module 24 V DC 40 A 160 ms 2021 06 21 Version 1 0...

Page 2: ......

Page 3: ...6 4 5 Operating diagrams 17 4 6 Active signal 18 4 7 Ready signal 18 4 8 Inhibit input 18 4 9 Efficiency and losses 18 4 10 Lifetime expectancy 19 4 11 MTBF 19 4 12 Functional wiring diagram 19 4 13 T...

Page 4: ...Table of contents PS2001 2440 0000 4 Version 1 0...

Page 5: ...C The device requires no control wiring It can be connected anywhere in parallel with the load circuit Buffer modules can be connected in parallel in order to increase the output current capacity or t...

Page 6: ...d XPlanar are registered trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could vi...

Page 7: ...device is designed for installation in a housing and is intended for general professional use for example in industrial control systems or office communication and measuring equipment Do not use this...

Page 8: ...ce is designed for areas with a degree of pollution 2 in controlled environments No con densation or frost is allowed The device housing offers IP20 protection The housing offers no protection against...

Page 9: ...e mode can also be called capacitor mode Inhibit mode Describes a state in which the buffering is deliberately disabled e g for service work T b d Still to be defined value or description will follow...

Page 10: ...is increases the reliability of the complete system Fig 2 Bridging power failures Extended hold up time Following a power failure or a power cut the buffer unit maintains the load current for a define...

Page 11: ...Basics PS2001 2440 0000 11 Version 1 0 Fig 5 Typical wiring Fig 6 Transition behavior...

Page 12: ...50 Ohm in power supply mode The residual ripple and noise voltage are defined by the power supply Current consumption Typ 80 mA When the capacitor is fully charged Min 400 mA During the charging of th...

Page 13: ...Technical data application notes wiring PS2001 2440 0000 13 Version 1 0 Fig 8 Output characteristic curve in buffer mode 22 5 V fixed mode typ...

Page 14: ...ries are used with back feeding loads if the buffer module is placed close to the load or in case of doubt Variable mode jumper in position 1 2 or VIN 1 V Buffering begins if the supply voltage drops...

Page 15: ...n the required output current The buffer time mainly depends on the output current in buffer operation Any number of buffer modules can be connected in parallel in order to increase the buffer time Bu...

Page 16: ...at a low frequency 1 25 Hz Charging time Min 29 s Initial charging 1 max 50 s Initial charging 1 min 24 s Recharging 2 max 40 s Recharging 2 1 Initial charging is the first charging after applying th...

Page 17: ...Technical data application notes wiring PS2001 2440 0000 17 Version 1 0 4 5 Operating diagrams Fig 12 Operating diagram Fig 13 Signal circuit diagram...

Page 18: ...while optocoupler has a low resistance Leakage current Max 50 A While optocoupler has a high resistance Insulation voltage See chapter Dielectric strength 23 4 8 Inhibit input The buffering can be inh...

Page 19: ...he statistical failure rate of the components and indicates the reliability of a device It is a statistical representation of the probability of equipment failure and does not necessarily represent th...

Page 20: ...ew terminals Connection cross section e max 16mm f max 10mm a max 10mm d 5 2mm e max 2 5mm f max 2 5mm a max 2 5mm d 2 25mm Connection cross section AWG e AWG 22 8 f AWG 22 8 a AWG 22 8 e AWG 22 14 f...

Page 21: ...nal 18 Ready signal for details see chapter Ready signal 18 Inhibit input for details see chapter Inhibit input 18 Status LED Designation D Description LED green This green LED shows the following inf...

Page 22: ...ctions accord ing to EN 61000 6 3 fulfilled Interference emission EN 55011 EN 55022 Class B Switching frequencies Charge converter on 24 V input is only ac tive during charging 6 to 610 kHz The freque...

Page 23: ...attempts to restart Internal input fuse Overvoltage protection at the input Max 35Vdc Device not damaged or defective Reverse polarity protection at the input Max 35 Vdc Device not damaged or defecti...

Page 24: ...nd approvals EU declaration of conformity UL Certificate UL508 Applicable for US and Canada UK Declaration of Conformity Trade conformity assessment for England Scotland and Wales The UKCA mark indica...

Page 25: ...he total installation depth required Weight 1040g DIN rail Use 35 mm DIN rails according to EN 60715 or EN 50022 with a height of 7 5 or 15mm Housing material Housing Aluminum alloy Cover galvanized s...

Page 26: ...ting ZS5301 0007 Bracket for side mounting This bracket is used in order to mount the devices laterally with or without the use of a DIN rail The two aluminum brackets and the black plastic slider of...