Foreword

PS2001-2440-0000

7

Version: 1.0

2.2

Safety instructions

Description of instructions

In this documentation the following instructions are used. 
These instructions must be read carefully and followed without fail!

 DANGER

Serious risk of injury!

Failure to follow this safety instruction directly endangers the life and health of persons.

 WARNING

Risk of injury!

Failure to follow this safety instruction endangers the life and health of persons.

 CAUTION

Personal injuries!

Failure to follow this safety instruction can lead to injuries to persons.

NOTE

Damage to environment/equipment or data loss

Failure to follow this instruction can lead to environmental damage, equipment damage or data loss.

Tip or pointer

This symbol indicates information that contributes to better understanding.

Intended use

This device is designed for installation in a housing and is intended for general professional use, for example
in industrial control systems or office, communication and measuring equipment.

Do not use this power supply in installations where a malfunction could cause serious injury or danger to
human life.

Exclusion of liability

All the components are supplied in particular hardware and software configurations appropriate for the
application. Modifications to hardware or software configurations other than those described in the
documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH & Co. KG.

Personnel qualification

This description is only intended for trained specialists in control, automation and drive engineering who are
familiar with the applicable national standards.

Safety regulations

Please note the following safety instructions and explanations!
Product-specific safety instructions can be found on following pages or in the areas mounting, wiring,
commissioning etc.

Summary of Contents for PS2001-2440-0000

Page 1: ...Documentation EN PS2001 2440 0000 Buffer Module 24 V DC 40 A 160 ms 2021 06 21 Version 1 0...

Page 2: ......

Page 3: ...6 4 5 Operating diagrams 17 4 6 Active signal 18 4 7 Ready signal 18 4 8 Inhibit input 18 4 9 Efficiency and losses 18 4 10 Lifetime expectancy 19 4 11 MTBF 19 4 12 Functional wiring diagram 19 4 13 T...

Page 4: ...Table of contents PS2001 2440 0000 4 Version 1 0...

Page 5: ...C The device requires no control wiring It can be connected anywhere in parallel with the load circuit Buffer modules can be connected in parallel in order to increase the output current capacity or t...

Page 6: ...d XPlanar are registered trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could vi...

Page 7: ...device is designed for installation in a housing and is intended for general professional use for example in industrial control systems or office communication and measuring equipment Do not use this...

Page 8: ...ce is designed for areas with a degree of pollution 2 in controlled environments No con densation or frost is allowed The device housing offers IP20 protection The housing offers no protection against...

Page 9: ...e mode can also be called capacitor mode Inhibit mode Describes a state in which the buffering is deliberately disabled e g for service work T b d Still to be defined value or description will follow...

Page 10: ...is increases the reliability of the complete system Fig 2 Bridging power failures Extended hold up time Following a power failure or a power cut the buffer unit maintains the load current for a define...

Page 11: ...Basics PS2001 2440 0000 11 Version 1 0 Fig 5 Typical wiring Fig 6 Transition behavior...

Page 12: ...50 Ohm in power supply mode The residual ripple and noise voltage are defined by the power supply Current consumption Typ 80 mA When the capacitor is fully charged Min 400 mA During the charging of th...

Page 13: ...Technical data application notes wiring PS2001 2440 0000 13 Version 1 0 Fig 8 Output characteristic curve in buffer mode 22 5 V fixed mode typ...

Page 14: ...ries are used with back feeding loads if the buffer module is placed close to the load or in case of doubt Variable mode jumper in position 1 2 or VIN 1 V Buffering begins if the supply voltage drops...

Page 15: ...n the required output current The buffer time mainly depends on the output current in buffer operation Any number of buffer modules can be connected in parallel in order to increase the buffer time Bu...

Page 16: ...at a low frequency 1 25 Hz Charging time Min 29 s Initial charging 1 max 50 s Initial charging 1 min 24 s Recharging 2 max 40 s Recharging 2 1 Initial charging is the first charging after applying th...

Page 17: ...Technical data application notes wiring PS2001 2440 0000 17 Version 1 0 4 5 Operating diagrams Fig 12 Operating diagram Fig 13 Signal circuit diagram...

Page 18: ...while optocoupler has a low resistance Leakage current Max 50 A While optocoupler has a high resistance Insulation voltage See chapter Dielectric strength 23 4 8 Inhibit input The buffering can be inh...

Page 19: ...he statistical failure rate of the components and indicates the reliability of a device It is a statistical representation of the probability of equipment failure and does not necessarily represent th...

Page 20: ...ew terminals Connection cross section e max 16mm f max 10mm a max 10mm d 5 2mm e max 2 5mm f max 2 5mm a max 2 5mm d 2 25mm Connection cross section AWG e AWG 22 8 f AWG 22 8 a AWG 22 8 e AWG 22 14 f...

Page 21: ...nal 18 Ready signal for details see chapter Ready signal 18 Inhibit input for details see chapter Inhibit input 18 Status LED Designation D Description LED green This green LED shows the following inf...

Page 22: ...ctions accord ing to EN 61000 6 3 fulfilled Interference emission EN 55011 EN 55022 Class B Switching frequencies Charge converter on 24 V input is only ac tive during charging 6 to 610 kHz The freque...

Page 23: ...attempts to restart Internal input fuse Overvoltage protection at the input Max 35Vdc Device not damaged or defective Reverse polarity protection at the input Max 35 Vdc Device not damaged or defecti...

Page 24: ...nd approvals EU declaration of conformity UL Certificate UL508 Applicable for US and Canada UK Declaration of Conformity Trade conformity assessment for England Scotland and Wales The UKCA mark indica...

Page 25: ...he total installation depth required Weight 1040g DIN rail Use 35 mm DIN rails according to EN 60715 or EN 50022 with a height of 7 5 or 15mm Housing material Housing Aluminum alloy Cover galvanized s...

Page 26: ...ting ZS5301 0007 Bracket for side mounting This bracket is used in order to mount the devices laterally with or without the use of a DIN rail The two aluminum brackets and the black plastic slider of...

Page 27: ...pendix PS2001 2440 0000 27 Version 1 0 5 2 Documentation issue status Version Comment 1 0 Addenda corrections 1st public issue 0 2 Addenda corrections 0 1 Preliminary documentation for PS9011 2440 000...

Page 28: ...nts there Beckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with other wide ranging services sup...

Page 29: ......

Page 30: ...Beckhoff Automation GmbH Co KG H lshorstweg 20 33415 Verl Germany Phone 49 5246 9630 info beckhoff com www beckhoff com More Information www beckhoff com ps9011 2440 0000...

Reviews: