Operation
EL1904
37
Version: 2.1.1
Parameter overview
PrmName
Meaning
Values
FSoE_Address
DIP switch address
1 to 65535
Operating Mode
Digital / standstill monitoring 1 and 2
Digital / standstill 1 and 2
Sensor test
channel 1 active
The clock signal for connection
is checked at connection Input1-.
true / false
Sensor test
channel 2 active
The clock signal for connection
is checked at connection Input2-.
true / false
Sensor test
channel 3 active
The clock signal for connection
is checked at connection Input3-.
true / false
Sensor test
channel 4 active
The clock signal for connection
is checked at connection Input4-.
true / false
Logic channel 1
and 2
Logic of channels 1 and 2
• single logic
• asynchronous repetition OSSD (sensor
test must be switched off)
• any pulse repetition OSSD (sensor test
must be switched off)
• short cut is no module fault
Logic channel 3
and 4
Logic of channels 3 and 4
• single logic
• asynchronous repetition OSSD (sensor
test must be switched off)
• any pulse repetition OSSD (sensor test
must be switched off)
• short cut is no module fault
Store Code
This parameter is required for the
TwinSAFE Restore Mode
0x0000
Project CRC
This parameter is required for the
TwinSAFE Restore Mode
0x0000
4.4.5.1
EL1904 configuration for light barriers, light grids, light curtains etc.
The EL1904 also supports direct connection of contact-free protective devices with two self-testing outputs
such as light barriers, light grids, light curtains, laser scanners, etc.
CAUTION
Sensors with self-testing outputs!
Only sensors with self-testing outputs and a maximum sensor self-test duration of 350 µs
may be connected to the EL1904 (see illustration below).