Mounting and wiring
CPX39xx-0010
22
Version: 0.1
5
Mounting and wiring
5.1
Mounting
The Control Panel CPX39xx is designed for industrial application in machine and plant engineering. The
Control Panel is intended for mounting arm installation either via 100 x 100 mm mounting interface. The
ambient conditions specified for operation must be observed (see chapter:
Technical Data [
}
33]
).
Permitted mounting position
The Control Panel may only be mounted horizontally.
5.1.1
Preparation of the Panel PC
Please note the following points during installation of the Control Panel:
• Position the Control Panel in such a way that reflections on the screen are avoided as far as possible.
• Use the position of the screen as a guide for the correct installation height; it should be optimally visible
for the user at all times.
• The Control Panel should not be exposed to direct sunlight.
NOTICE
Avoid extreme environmental conditions
Extreme environmental conditions should be avoided as far as possible. Protect the Control Panel from
dust, moisture and heat.
Earthing measures
Earthing connections dissipate interference from external power supply cables, signal cables or cables to
peripheral equipment. Establish a low-impedance connection from the earthing point on the Control Panel
housing to the central earthing point on the control cabinet wall, in which the Control Panel is being installed.
Summary of Contents for CPX3915-0010
Page 2: ......
Page 4: ...Table of Contents CPX39xx 0010 4 Version 0 1 10 4 Support and Service 38...
Page 26: ...Mounting and wiring CPX39xx 0010 26 Version 0 1 5 2 3 Fitting the power supply...
Page 30: ...Assembly dimensions CPX39xx 0010 30 Version 0 1 8 Assembly dimensions CPX3915 0010...
Page 31: ...Assembly dimensions CPX39xx 0010 31 Version 0 1 CPX3919 0010...
Page 32: ...Assembly dimensions CPX39xx 0010 32 Version 0 1 CPX3921 0010...