Commissioning
CP6606
23
Version: 2.0
A
B
C
D
Fig. 13: CP6606_Assembly of strain relief housing
To remove the strain relief housing, proceed as follows:
1. Use your fingers to bend the latching lugs on the lower part slightly outward (see Fig. 14).
2. Lever the upper part off the lower part.
3. Cut the cable tie.
Fig. 14: CP6606_Disassembly of strain relief housing