Operating Instructions 

 

 

24

 

CP37xx 

5  Operating Instructions 

5.1  Switching the Panel PC on and off 

5.1.1  Switching on 

The Panel PC does not have its own mains power switch. As soon as the power supply is switched on the 
Panel PC is activated. 

5.1.2  Shutting down and switching off 

Control software such as is typically used on Industrial PCs permits various users to be given different 
rights. A user who may not close software may also not switch the Panel PC off, since data can be lost 
from the storage medium by switching off while software is running. 

 

Warning 

First shut down, then switch off! 

If the Panel PC is switched off as the software is writing a file to the storage medium, 
the file will be destroyed. Control software typically writes something to the storage 
medium every few seconds, so that the probability of causing damage by switching off 
while the software is running is very high. 

 

 

Warning 

Switch off power supply 

When you have shut down the Panel PC, you have to switch off power supply for at 
least 10 seconds before rebooting the system. 

After resetting power supply the Panel PC will start booting automatically. 

 

5.1.3  First switching on and driver installation 

When you switch on the Industrial PC for the first time, the pre-installed operating system (optional) will 
be started. In this case, all the required drivers for any additional, optional hardware components ordered 
with the PC will already have been installed. 

If the PC was ordered without operating system, you have to install the operating system and the driver 
software for any auxiliary hardware yourself. Please follow the instructions in the documentation for the 
operating system and the additional devices. 
 

5.2  Operation 

The operation of the Panel PC occurs via the Touch Screen. 

 

Warning 

Risk of damaging the Touch Screen 

The touch screen may only be actuated by finger tips or with the touch screen pen. The 
operator may wear gloves but there must be no hard particles such as metal shavings, 
glass splinters embedded in the glove. 

 

 

Warning 

Properly installation of the system and the multi-touch device 

Capacitive Touch Screens use the functional principle of capacitive alternation of the 
electrical field. Strong electrical fields can influence the functionality of the multi-touch 
devices. 

To ensure the correct function of the Touch Screen take care of a standardized 
installation of all parts of the system and an EMC-environment conforming to 
standards. 

Summary of Contents for CP37 Series

Page 1: ...Installation and Operating instructions for CP37xx Multi touch Panel PC Version 1 4 Date 2020 10 28...

Page 2: ......

Page 3: ...scription 7 2 1 Product overview 7 2 2 Appropriate Use 9 2 3 Access to the connectors 9 2 3 1 Installing the Cables 10 2 4 Connections 11 2 4 1 Network Interface X101 11 2 4 2 Power Supply X102 12 2 4...

Page 4: ...on 24 5 1 2 Shutting down and switching off 24 5 1 3 First switching on and driver installation 24 5 2 Operation 24 5 3 Servicing and maintenance 25 5 3 1 Cleaning 25 5 3 2 Maintenance 25 5 3 3 Repla...

Page 5: ...XFC and XTS are registered trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could...

Page 6: ...of individuals WARNING Risk of injury If you do not adhere the safety advise adjoining this symbol there is danger to life and health of individuals CAUTION Hazard to individuals If you do not adhere...

Page 7: ...a repair all parts of the equipment must first be switched off after which the Panel PC is to be disconnected from the equipment Disconnect the device by unplugging the connectors on the rear side of...

Page 8: ...uct Note Do not open the housing of the Panel PC For technical support contact Beckhoff Service 1 4 1 National regulations Depending on the type of machine and plant in which the Industrial PC is used...

Page 9: ...adapter for a 48 mm diameter mounting arm tube There is a choice of attaching the mounting arm from above or below The connecting cables are laid through the mounting arm The Industrial PC connection...

Page 10: ...for Rittal and Rolec mounting arm systems with 48 mm tube from top optional from the bottom wiring area for up to 4 IP65 connectors 2 slots for CFast cards CFast cards and lithium battery of the syst...

Page 11: ...g The Panel PC is designed for mounting arm installation Danger Risk of explosion The Control Panel must not be used where there is a risk of explosion 2 3 Access to the connectors The connectors of t...

Page 12: ...ctions The installation of the cover takes place in reverse order 2 3 1 Installing the Cables After opening the connection area you have access to the connections of the Control Panel The cables with...

Page 13: ...tion class accords to the IP65 standard Pin Signal Housing Screen 1 TD 2 TD 3 RD 4 NC 5 NC 6 RD 7 NC 8 NC For network connection following Harting Push Pull connector RJ45 8 pole can be used Connector...

Page 14: ...ore cables To connect the power supply and the battery pack 2 wires per pin are used when using 12 core cables to halve the voltage drop across the cable Pin Wire Function Pin Wire Function 1 1 8 Batt...

Page 15: ...3 connector screw type 12 wires second end open 2 5 2 Ethernet connection cables optional The following Ethernet connection cables are available Patch cable Network cable with IP65 connector C9900 K28...

Page 16: ...e two screws see arrows with a star screwdriver Torx size 10 the cover plate can be taken off Removing the cover plate allows access to the CFast card slots 1 und 2 and the lithium battery 3 WARNING D...

Page 17: ...that moisture condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a delay time of approximate...

Page 18: ...n be installed from the bottom Order Option Description C9900 M184 Mounting arm adapter for Panel PC CP37xx for Rittal and Rolec mounting arm systems with 48 mm tube from bottom instead of from top No...

Page 19: ...ng arm adapter all the way to stop Now the slotted nut of the mounting arm adapter is tightened carefully clockwise using a hook wrench SW 58 62 2 Also the mounting arm tube is locked by tightening th...

Page 20: ...n first remove the cover of the Panel PC see also chapter Access to the connectors The adapter is equipped with a brake mechanism 1 for tilting the Control Panel To adjust the mounting arm tilt functi...

Page 21: ...PS When the Industrial PC is provided with a power supply unit with integrated UPS order option you can realize an uninterruptible power supply UPS using the battery pack C9900 U330 WARNING Danger of...

Page 22: ...olution uses an ON OFF switch for the machine Basically the main switch remains switched on and provides the power supply for the PC during shutdown Via the PC ON input of the power supply the PC gets...

Page 23: ...t you have assembled into the Industrial PC s power supply socket Then connect it to your external 24 V power supply Attention Use same type of rechargeable battery If a 24 V UPS is installed the same...

Page 24: ...Wiring according to the wiring diagram the circuit of PC_ON and Power Status is symbolical Note Connection of the Battery Pack and UPS Output Connection of the Battery Pack and UPS Output only in comb...

Page 25: ...Disconnect the Panel PC from the power supply Connect all cables at the Panel PC and at the devices to be connected Ensure that all screw connections between connectors and sockets are tight Reconnect...

Page 26: ...matically 5 1 3 First switching on and driver installation When you switch on the Industrial PC for the first time the pre installed operating system optional will be started In this case all the requ...

Page 27: ...ufacturer Notice correct polarity WARNING Handling of Lithium Batteries Lithium Batteries should not be recharged exposed to fire opened and they should be protected against sunlight and moisture The...

Page 28: ...PC the drivers can be installed from the driver CD provided To install the UPS driver software execute file Beckhoff_UPS_vx xx xx exe from the subdirectory of UPS from the CD provided on the Industria...

Page 29: ...ll Beckhoff Service Panel PC boots software starts but control does not operate correctly Cause of the fault is either in the software or in parts of the plant outside the Panel PC Call the manufactur...

Page 30: ...ions of the Panel PC please visit our homepage Here you will find the actual drawings using the link http www beckhoff de german download technical_drawings htm Warning Notice mounting orientation The...

Page 31: ...34 W CP3721 approx 41 W CP3716 approx 27 W CP3724 approx 48 W CP3718 approx 39 W Interfaces 1 x RJ 45 Ethernet 100 1000 Mbit Protection class IP65 Shock resistance Sinusoidal vibration EN 60068 2 6 10...

Page 32: ...tion GmbH Co KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 E mail info beckhoff de Web http www beckhoff de Beckhoff Support Support offers you comprehensive techn...

Page 33: ...nerates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equ...

Reviews: