background image

 

Table of contents 

 

C9900-P223 / C9900-P224 

Table of contents 

1. 

Foreword 2

 

Notes on the Documentation 

2

 

Liability Conditions 

2

 

Trademarks 2

 

Patent Pending 

2

 

Copyright 

2

 

State at Delivery 

2

 

Delivery conditions 

2

 

Description of safety symbols 

3

 

Basic safety measures 

4

 

Operator's obligation to exercise diligence 

4

 

2. 

Product Description 

5

 

Appropriate Use 

5

 

Beckhoff power supply technology 

5

 

Electrical data 

6

 

3. 

Installation Instructions 

7

 

Configuration and installation 

7

 

Connection with the motherboard 

8

 

Pin assignment 

8

 

Connection with the Industrial PC 

9

 

Pin assignment of the connector 

9

 

External wiring 

10

 

Cable Cross Sections 

10

 

PC_ON and Power Status functions 

10

 

UPS output, C9900-P224 only 

11

 

UPS output function 

11

 

Wiring diagram 

11

 

Fitting the cable 

12

 

Material for assembling the connectors 

12

 

Assembling the connectors 

12

 

4. 

Operating Instructions 

13

 

UPS Software Components (only C9900-P224) 

13

 

Installation on the PC 

13

 

Help files 

13

 

Servicing 13

 

Shutting down 

13

 

Disposal 

13

 

5. 

Troubleshooting 14

 

Beckhoff Support & Service 

14

 

Beckhoff branches and partner companies 

14

 

Beckhoff Headquarters 

14

 

Beckhoff Support 

14

 

Beckhoff Service 

14

 

6. 

Appendix 15

 

Technical data 

15

 

Approvals 15

 

FCC: Federal Communications Commission Radio Frequency Interference 
Statement 15

 

FCC: Canadian Notice 

15

 

 

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Summary of Contents for C9900-P223

Page 1: ...Installation and Operating instructions for C9900 P223 and C9900 P224 Power Supply Units Version 1 2 Date 2012 02 22 Downloaded from Arrow com...

Page 2: ...Downloaded from Arrow com Downloaded from Arrow com...

Page 3: ...tor 9 External wiring 10 Cable Cross Sections 10 PC_ON and Power Status functions 10 UPS output C9900 P224 only 11 UPS output function 11 Wiring diagram 11 Fitting the cable 12 Material for assembling...

Page 4: ...r designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners Patent Pending The EtherCAT Technology is covered inc...

Page 5: ...he safety advise adjoining this symbol there is danger to life and health of individuals Hazard to individuals CAUTION If you do not adhere the safety advise adjoining this symbol there is obvious haz...

Page 6: ...tems of equipment that have been switched off must be secured against being switched on again Do not open the power supply unit while voltage is applied WARNING The supply voltage must be switched off...

Page 7: ...Beckhoff power supply technology approach addresses this problem and now offers the user the option of switching the PC off without the need for using the battery thereby reducing the load on the bat...

Page 8: ...nel with a display dimension up to 19 inches This enables a power failure to be visualized and displayed to the user Once the PC has shut down the UPS output is switched off For a detailed functional...

Page 9: ...position in the Industrial PC The figure shows the supply connections for the power supply unit 1 and the electrical connections for the motherboard 2 1 2 Downloaded from Arrow com Downloaded from Ar...

Page 10: ...RS232 interface view from power supply PS_ON TTL input voltage request from motherboard High motherboard reports stand by Low motherboard reports connect voltage Powergood TTL output Low voltages at...

Page 11: ...e connected to the UPS output of the C9900 P224 The maximum current loading is 1 4 A Pin assignment of the connector The power supply and the external circuit for switching the Industrial PC on and of...

Page 12: ...ected to 24 V via a switch the PC shuts down according to the rules The PC_ON signal is inverted i e the PC shuts down if the 24 V connection is live If the PC_ON input is NOT connected by the user th...

Page 13: ...UPS software the UPS output is switched to 0 V Any connected panel is thus switched off and total discharge of the rechargeable battery is prevented Wiring diagram Wiring according to the wiring diag...

Page 14: ...on from the cable ends Length of stripped conductor is 8 9 mm 2 Screw together the cable ends in the 8 pole plug connector in accordance with wiring diagram Applying the strain relief Thread the lacin...

Page 15: ...utine Help files Beckhoff Information System The driver software comes with a detailed help function The help files can be called up either directly from the configuration register by clicking the Hel...

Page 16: ...cal assistance helping you not only with the application of individual Beckhoff products but also with wide ranging services worldwide support design programming and commissioning of complex automatio...

Page 17: ...tions Commission Radio Frequency Interference Statement FCC Approval for USA This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the...

Reviews: