Technical data 

Dimensions 

Dimensions (W x H x D):

  

483 x 177 x 449 (+ 51 with handles) mm 

 
Weight:

 

17.0 kg (basic configuration) 

 

Do not use the PC in areas 
of explosive hazard 

The Industrial PC may not be used in areas of explosive hazard. 

 

 

The following conditions must be observed during operation: 

Environmental conditions 

Ambient temperature:

  

0 to 55°C 

Atmospheric humidity:

 

Maximum 95%, non-condensing 

 

Shock resistance 

Sinusoidal vibration:   
(EN 60068-2-6)

 

10 to 58 Hz:

 

0.035 mm 

 

58 to 500 Hz:  0.5 G (~ 5 m/ s

2

)  

During reading of CD-ROM:

 

10 to 58 Hz:

 

0.019 mm  

 

58 to 500 Hz:  0.25 G (~ 2.5 m/ s

2

Impact: 
(EN 60068-2-27/ -29)

 

5 G (~ 50 m/ s²), duration: 30 ms 

During reading of CD-ROM:

 

5 G (~ 50 m/ s²), duration: 11 ms 

Protection class 

Protection class: 

IP20

 

 

Power supply 
100-240 V

AC

 power supply 

unit 

Supply voltage:

 

100-240 V 50-60 Hz 

Power consumption:

 

C5101-0020:  68 W for the basic version 

 

C5101-0030:  93 W for the basic version 

Electromagnetic 
Compatibility (EMC) 

Interference resistance:

 

according to EN 61000-6-2

  

Emitted resistance:

 

according to EN 61000-6-4 

Transport and storage 

The same values for atmospheric humidity and shock resistance are to be 
observed during transport and storage as in operation. The shock 
resistance during transport can be improved by means of suitably packing 
the Industrial PC. The ambient temperature during storage and transport 
must be between -20°C and +65°C. 

 

 

Approvals 

 

FCC: Federal Communications Commission     
Radio Frequency Interference Statement 

FCC Approval for USA 

This equipment has been tested and found to comply with the limits for a 
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits 
are designed to provide reasonable protection against harmful interference 
when the equipment is operated in a commercial environment. This 
equipment generates, uses, and can radiate radio frequency energy and, if 
not installed and used in accordance with the instruction manual, may 
cause harmful interference to radio communications. Operation of this 
equipment in a residential area is likely to cause harmful interference in 
which case the user will be required to correct the interference at his own 
expense. 

 

FCC: Canadian Notice 

FCC Approval for Canada 

This equipment does not exceed the Class A limits for radiated emissions 
as described in the Radio Interference Regulations of the Canadian 
Department of Communications. 

 

Summary of Contents for C5101

Page 1: ...Installation and Operating instructions for 19 Inch Rack Mount Industrial PC C5101 Version 1 5 Date 2008 06 09...

Page 2: ......

Page 3: ...pushbutton 9 Installation Instructions 10 Transport and Installation 10 Transport 10 Unpacking 10 Installation 10 Power Supply Connection 11 Mains Socket 11 Power supply cords 11 Connecting devices 1...

Page 4: ...Table of contents 6 7 Assembly dimensions 17 Appendix 18 Technical data 18 Approvals 18 FCC Federal Communications Commission Radio Frequency Interference Statement 18 FCC Canadian Notice 18 2 C5101...

Page 5: ...ing of 443 BGB of the German Civil Code or a statement about the contractually expected fitness for a particular purpose in the meaning of 434 par 1 sentence 1 BGB In the event that it contains techni...

Page 6: ...oupled from the plant Pulling out the fieldbus connection plug uncouples the PC optional Items of equipment that have been switched off must be secured against being switched on again The Industrial P...

Page 7: ...ional regulations depending on the machine type Depending on the type of machine and plant in which the Industrial PC is being used there will be national regulations for the control of such machines...

Page 8: ...pening the front flap In order to gain access to the power pushbutton and to the drives open the flap on the front with the key provided for the purpose see photo above Rear view of the C5101 Warning...

Page 9: ...plug in cards see following photograph Removing the card holder Remove the 2 fastening screws of the card holder see arrows using a cross head screwdriver The holder can then be lifted up View of the...

Page 10: ...5 connector 4 allows the PC to be connected to a 10 100BASE T Local Area Network LAN DVI Digital Visual Interface DVI I The DVI connection 5 is used for transferring the video signal DVI I standard is...

Page 11: ...EDs Power The LED Power 2 indicates correct power supply HDD The LED HDD 3 indicates HDD access USB interfaces USB4 USB5 The two USB interfaces 4 are used to connect peripheral devices with USB connec...

Page 12: ...ion the unit must be allowed to slowly adjust to room temperature Should condensation occur a delay time of approximately 12 hours must be allowed before the unit is switched on Unpacking Proceed as f...

Page 13: ...upply Socket at the PC housing Power supply cords Power cords Europe In the area Europe you use the provided cable with inlet connector for non heating apparatus to connect the Industrial PC to the po...

Page 14: ...en connecting the cables to the Industrial PC proceed according to the following sequence Switch off all the devices that are to be connected Disconnect all the devices that are to be connected from t...

Page 15: ...the hard disk the file will be destroyed Control software typically writes something to the hard disk every few seconds so that the probability of causing damage by switching off while the software is...

Page 16: ...used batteries according to the manufacturer s instructions Servicing The Industrial PC requires no maintenance if it is used in an environment where dust levels are low If the Industrial PC is used...

Page 17: ...r cause Check power supply cable Call Beckhoff Service The Industrial PC does not boot fully CD in drive Setup settings are incorrect Other cause Remove CD and press any key Check the setup settings C...