9.3.6
Feedback
Press function key F12 (disable) before chan-
ging feedback parameters.
Feedback Type:
Select the feedback type used.
Leave all other fields unchanged.
If Software Enable is active, a warning appears.
The configuration change cannot be performed.
Click OK on the warnings, press F12 (SW disab-
le) and start the Feedback procedure again.
If everything was ok, the same procedure (para-
meter upload) that has been described for the
motor selection starts.
If you click "Yes", the parameters are saved in
the EEPROM and the amplifier makes a cold-
start (reset). This takes some seconds.