8.12.1
Connection to a AX20 master, 5 V signal level (X5)
You can link several AX20 amplifiers together in master-slave operation. Up to 16 slave amplifiers
can be controlled by the master via the encoder output. The connector X5 must be used.
Frequency limit: 1.5 MHz, slew rate tv
£
0,1 µs
AGND and DGND (connector X3) must be joined together !
8.12.2
Connection to incremental encoder master with 24 V signal level (X3)
This interface can be used to operate the AX2040/2070 as a slave, mastered by an encoder with 24
V signal level (master-slave operation). The digital inputs DIGITAL-IN 1 and 2 at connector X3 must
be used.
Frequency limit: 250 kHz, slew rate tv
£
0.1 µs
AGND and DGND (connector X3) must be joined together !
AX2040/2070 Product Manual
57
BECKHOFF
06/2007
Electrical Installation
AX2040/2070
AX20
AX2040/2070