background image

The R. W. BECKETT CORPORATION (“Beckett”) warrants to persons who purchase its “Products” from Beckett 
for resale, or for incorporation into a product for resale (“Customers”), that its equipment is free from defects 
in material and workmanship. To qualify for warranty bene

fi

 ts, products must be installed by a quali

fi

 ed service 

agency in full compliance with all codes and authorities having jurisdiction, and used within the tolerances of 
Beckett’s de

fi

 ned product speci

fi

 cations. 

To review the complete warranty policy and duration of coverage for a speci

fi

 c product, or obtain a written copy 

of warranty form 61545, please choose one of the following options:

Visit our website at: www.beckettcorp.com/warranty 
Email your request to:  [email protected]
Write to:  R. W. Beckett Corporation, P. O. Box 1289, Elyria, OH 44036

NOTE:  Beckett is not responsible for any labor cost for removal and replacement of equipment.

THIS WARRANTY IS LIMITED TO THE PRECISE TERMS SET FORTH ABOVE, AND PROVIDES EXCLUSIVE 
REMEDIES EXPRESSLY IN LIEU OF ALL OTHER REMEDIES, AND IN PARTICULAR THERE SHALL BE 
EXCLUDED THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 
PURPOSE.  IN NO EVENT WILL BECKETT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL 
DAMAGE OF ANY NATURE.  Beckett neither assumes, nor authorizes any person to assume for Beckett, 
any other liability or obligation in connection with the sale of this equipment. Beckett’s liability and Customer’s 
exclusive remedy is limited to the cost of the product.

1.
2.
3.

Limited Warranty Information

USA:

 P.O. Box 1289 

 Elyria, Ohio 44036

Canada:

 R.W. Beckett Canada, Ltd. 

 Unit #3, 430 Laird Road 

 Guelph, Ontario N1G 3X7

www.beckettcorp.com

Part Number 6104 B24SDC R01, Printed in the U.S.A. 07/11

Summary of Contents for SDC 24 VDC

Page 1: ...E INSTRUCTIONS AND SAVE FOR REFERENCE y y y Incorrect installation adjustment or misuse of this burner could result in death severe personal injury or substantial property damage To the Professional Q...

Page 2: ...t up 10 C Set Combustion with Instruments 10 Maintain Service Burner 11 A Owner s Information 11 B Owner Service and Maintenance 11 C Extended Down Time 11 D Regular Service Maintenance 11 Troubleshoo...

Page 3: ...burners may be agency listed as a unit to operate beyond these limits Consult the appliance manufacturer s specifications and agency approvals for verification y y Prepare Before Installing Specifica...

Page 4: ...f the enclosure Each opening shall have a free area of not less then one square inch per 1 000 BTU s per hour of the total input rating of all equipment within the enclosure The openings shall have fr...

Page 5: ...efore installation Do NOT attempt to install or remove a nozzle without securing the adapter to prevent seriously damaging the alignment Use care when handling the nozzle line assembly to prevent chan...

Page 6: ...elease the igniter baseplate Then tilt the igniter back on its hinge Remove the splined nut b Remove the nozzle line assembly from the burner being careful not to damage the electrodes or 1 2 3 4 insu...

Page 7: ...Tape fragments can lodge in fuel line components and fuel unit damaging the equipment and preventing proper operation Use oil resistant pipe sealant compounds y y y The burner may be equipped with a s...

Page 8: ...rated at 50 amps or less Motor off delay on a 7559P will be disabled if the safety and operating limits as shown in Figure 6 interrupt power to the control s red 24 volt wire Do not wire power directl...

Page 9: ...the wires Restore power start the burner and perform the combustion test described previously in this manual 1 2 3 4 5 6 7 8 9 10 Figure 7 Blower Wheel CENTER WHEEL FOR EQUAL DISTANCE FROM HOUSING SI...

Page 10: ...ovided in this installation manual y y y y C Solenoid Valve Testing To check solenoid operation perform the following Check for oil flow and operating pressure by removing the copper tubing from the n...

Page 11: ...the Replacement Parts exploded view for part locations Replace the oil supply line filter if applicable The line filter cartridge must be replaced to avoid contamination of the pump and nozzle Inspect...

Page 12: ...any dirt asphalt or other material Check motor current The amp draw should not exceed the nameplate rating Check all wiring for loose connections or damaged insulation Check the pump pressure and cut...

Page 13: ...following possibilities Check voltage at the motor to insure that switches and relays in line with the motor are operating properly Refer to section Burner Wiring Check pump and motor shaft operation...

Page 14: ...Air Shutter 10 slot 3215 7 Pump Specify 8 Connector Tube Assembly 5394 9 Oil Valve 22246 10 Brass Elbow 2256 11 Cord Set Valve 21807 12 Splined Nut 3666 Illustration Description Part 13 Escutcheon Pla...

Page 15: ...15 24 Vdc SDC Burner Manual...

Page 16: ...e to R W Beckett Corporation P O Box 1289 Elyria OH 44036 NOTE Beckett is not responsible for any labor cost for removal and replacement of equipment THIS WARRANTY IS LIMITED TO THE PRECISE TERMS SET...

Reviews: