background image

084-1

21078

This Beckett DP Series centrifugal pump is magnetically driven and contains no seals to leak or wear 
out.  It also contains no oil as other types of submersible utility pumps do, thereby eliminating the pos-
sibility of oil leaks which can foul your water.  All electrical parts and connections are completely en-
capsulated with epoxy.  These features, combined with very low energy consumption, make for a safe 
and convenient pump which is economical to operate.  In addition, it is essentially maintenance-free.

The Beckett DP Series pump is designed to operate completely submerged.  Cleaning of the filter can 
be  reduced by placing the pump on a brick or patio stone in the water to raise it above the level of the 
debris which accumulates on the bottom.

  

Use:

Prefilters are supplied with the pump.  Using and maintaining clean prefilters will greatly decrease 
maintenance in cleaning the impeller assembly as well as providing better water filtration and pump 
flow. See Page 2 - Prefilter Cleaning.

Prefilter:

The only serviceable part is the impeller assembly.  It can be cleaned and inspected by removing the 
screws holding the volute housing in place and lifting out the housing and impeller assembly. See Page 
3 for diagram.  Never attempt to disassemble the impeller assembly.  If it becomes worn or broken, 
simply replace the entire assembly.  If the pump is taken out of service for a period of time (such as 
during winter), flush the pump out with clean fresh water and drain thoroughly before storing.  Ensure 
that the cord is protected from wear and abrasion.

NEVER ATTEMPT TO REPLACE OR SHORTEN THE CORD!

Service and

Maintenance:

1. RISK OF ELECTRIC SHOCK – 

This pump is supplied with a grounding conductor and a ground-

ing-type attachment plug (3-prong plug).  To reduce the risk of electric shock, be certain that it is 
connected only to a properly grounded, grounding-type receptacle.  Do not remove the grounding 
pin.

2. RISK OF SEVERE ELECTRIC SHOCK –

 Connect only to a grounded receptacle protected 

by a ground-fault circuit-interrupter (GFCI).  A GFCI must be provided in accordance with Section 
680-51 of the national electric code.  Contact a qualified electrician if you cannot verify that the 
receptacle is protected by the GFCI.

3. TO REDUCE THE RISK OF ELECTRICAL SHOCK:

A.  Never use an extension cord to connect unit to electrical supply; provide a properly located 

GFCI   outlet.

B.   Never bury the 3-prong plug of the cord, it is not waterproof and severe electric  shock will 
       occur.

Your Beckett DP Series pump is cooled and lubricated with water. If the pump is plugged in while it 
is out of the water, it is normal for it to rattle. However, while it will continue to operate if allowed to 
run dry, it will sustain permanent heat damage after 30 minutes.  Your Beckett DP Series pump is in-
tended to pump fresh water only.  Do not use to pump oils, solvents, fuels, or salt water.  Do not allow 
to freeze.

     

SAFETY        

WARNING:

Note:

PUMP 

MODEL #

VOLTS

Hz

AMPS

WATTS

MAX.

HEAD

APPROXIMATE PUMP FLOW (GPH @ HEAD)

USING 1” ID HOSE 0N DP800 & DP1200 

and a 1-1/2” ID HOSE ON DP1800 

0’

1’

3’

5’

DP800

115

60

.90

70

12’-9”

900

814

652

512

DP1200 

115

60

2.2

150

14’-8”

1350

1232

962

740

DP1800

115

60

2.2

230

16’-4”

1875

1764

1475

1267

PUMP MODEL NUMBER AND INFO LOCATED ON PUMP BACKPLATE NEAR POWER CORD

CAUTION:

1.  This pump has been evaluated for use with water only.
2. Disconnect pump from power source before handling, servicing or working in the water in which the 

pump is operating.

B E C K E T T

C O R P O R A T I O N

N o r f o l k   •   V i r g i n i a

Summary of Contents for DP800

Page 1: ...OCK This pump is supplied with a grounding conductor and a ground ing type attachment plug 3 prong plug To reduce the risk of electric shock be certain that it is connected only to a properly grounded grounding type receptacle Do not remove the grounding pin 2 RISK OF SEVERE ELECTRIC SHOCK Connect only to a grounded receptacle protected by a ground fault circuit interrupter GFCI A GFCI must be pro...

Page 2: ...k pump for proper operation After you have everything working to your satisfac tion you can cover up hide power cord You may now enjoy your pond You may want to review the versatility add on accessories section of the instructions to familiarize yourself with what you can accomplish with your new pump system PREFILTER CLEANING When you see a reduced flow from your pump it is time to clean the filter...

Page 3: ...090 070239 1 2D THRUST WASHERS 090 040015 090 040021 090 040023 2 2E END CAPS 078 110157 078 110079 078 110277 2 3 GASKET 078 110031 078 110078 078 110078 1 4 VOLUTE HOUSING 078 110005 078 110261 078 110260 1 5 PHILLIPS HEAD SCREWS 090 010063 090 010063 090 010063 4 6 6 INTAKE STRAINER ASSY 096 110009 096 110009 096 110009 2 7 T FITTING 078 110276 078 110276 078 110276 1 8 1 ID HOSE ADAPTOR 078 11...

Page 4: ... 1 Please refer to Pages 5 and 6 they provide you some information on the POND ACCESSORIES WATER FEATURES and POND ACCENT ACCESSORIES shown in the illustration above 2 You will find some information there about each accessory feature and accent that describes its use advantages it provides for you and its benefits to your pond as well as providing you options in setting up your pond and adding fea t...

Page 5: ...not only ornamentally enjoyable it is also beneficial in aeration and for movement of the pond water creating a healthier plant and fish environment Can be used with DP800 DP1200 pumps only you must remove the 1 hose adaptor before installing Using the fountain kit with your DP800 or DP1200 pumps will still allow you to power a medium size water feature thru the two way valve using 3 4 ID hose NOZZL...

Page 6: ...e and attach to your existing pond pump with a vinyl hose Sizes vary from 12 to 48 in length and may be purchased in many different forms and shapes 7 SKIMMER SYSTEM A pond skimmer is an excellent addition to a pond they keep ponds looking clean and keep de bris off the water surface When debris is allowed to stay on the surface it will eventually sink decay and cause unwanted elements and gases i...

Reviews: