Instruction Manual – 

Model AF Oil Burner 

Beckett 

Contents 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

Prepare before installing 

Verify specifications ……………………………….…………………..…….………….. 3 
Be aware of hazard definitions …………….…………….…..………..……………….. 3 

 

Check certifications/approvals ……………………………………..…………………... 3

 

Notice special requirements ………………….…………...…………..……………….. 3 

 

Prepare burner & site 

Inspect/prepare installation site ……………………...…………..……………………. 4 
Prepare burner ……………………………...…..…………………..…………………… 5 
Check/adjust “Z” dimension …………….………………………..……….……………. 6 

 

Pipe, wire, & adjust burner 

Mount burner on appliance ………………………………..…………..……………….. 7 
Connect fuel lines ………………………………………………………..……………… 7 
Wire burner ………………………………………………………………..……………... 7 

 

Startup & adjust burner 

Startup burner/set combustion ………..……………..….…………..…………………. 9 
Set combustion with instruments …………..………….…………..…………………... 9 

 

Service & maintain burner 

Perform regular maintenance …………………..……….……………..……….……… 9 
To replace the blower wheel ………………………..……………….…………………. 9 
Replacement parts ………………………………………………………………………. 10 
Owner’s information………. ………………………………….………….……………... 11 
Owner service and maintenance……………………………………………………….. 12 
Warranty……………………………………………………………………………………12

 

 
 
 
 

 

 
 
 
 
 

   

Table 1

 – Air Tube Combination (ATC) codes* 

 

Firing rate 

(GPH) 

Static 

plate 

size 

ATC codes for usable air tube lengths: 

(“A” in inches; see Figure 2, page 6) 

 

(min-max) 

Head 

(inches) 

4 ½  

 

 

7 ¼  

10 ½  

13 

16 

 0.40-0.75  F0 3 

 U

 

AF44XR AF53XR AF65XR AF72XR AF90XR AF104XR AF130XR AF160XR 

 

0.75-1.25 

F3 

2 ¾  

AF44XN 

AF53XN 

AF65XN 

AF72XN 

AF90XN 

AF104XN 

AF130XN 

AF160XN 

 0.85-1.35 F4  2 

¾  AF44WH AF53WH AF65WH AF72WH AF90WH AF104WH AF130WH AF160WH 

 

0.85-1.65 

F6 

2 ¾ 

AF44YB 

AF53YB 

AF65YB 

AF72YB 

AF90YB 

AF104YB 

AF130YB 

AF160YB 

 1.10-2.00  F12  2 

¾  AF44XO

 

AF53XO

 

AF65XO

 

AF72XO

 

AF90XO

 

AF104XO

 

AF130XO

 

AF160XO

 

 

1.65-2.50 

F22 

2 ¾ 

AF44XP 

AF53XP 

AF65XP 

AF72XP 

AF90XP 

AF104XP 

AF130XP 

AF160XP 

 

2.50-3.00 F31 None AF44XS AF53XS AF65XS AF72XS AF90XS AF104XS AF130XS AF160XS 

*Refer to Beckett 

OEM Specification Guide

, Part No. 6711, for non-standard air tube combinations

 

Summary of Contents for AF104WH

Page 1: ...AF Oil Burner MODEL Instruction Manual AF Type F air tube combinations Voltage 120 Vac 60 Hz Model AF Burner Beckett...

Page 2: ...ntenance 12 Warranty 12 Table 1 Air Tube Combination ATC codes Firing rate GPH Static plate size ATC codes for usable air tube lengths A in inches see Figure 2 page 6 min max Head inches 4 5 6 7 9 10...

Page 3: ...with all burners compared to the standard fuels Reduced deposits extend the service interval for cleaning and improve the efficiency of the appliance over time Low sulfur fuels reduce particulate and...

Page 4: ...e burner cannot properly burn the fuel This would result in incomplete combustion causing sooting and possible emission of carbon monoxide Severe personal injury death or substantial property damage c...

Page 5: ...rt number 6711 Verify that the electrode tip settings comply with Figure 1 If the nozzle is not installed obtain a nozzle of the manufacturer capacity and spray angle specified in appliance manufactur...

Page 6: ...for dimension A greater than 4 2 Use the following procedure to adjust the Z dimension if it is not correct Turn off power to the burner Disconnect the oil connector tube from the nozzle line See Fig...

Page 7: ...ad cell primary controls Burner wiring may vary depending on primary control actually used The oil valve shown in Figures 4 and 5 may be an optional feature Connect fuel lines All wiring must be in ac...

Page 8: ...connect power before servicing Figure 5 Typical wiring R7184 primary control R7184P shown DANGER Electrical shock hazard Disconnect power before servicing DANGER SK9359 SK9437 Feature R7184A R7184B R7...

Page 9: ...hnician s Quick Reference Guide Beckett part number 61351 for special pump priming sequence Check all wiring for secure connections or insulation breaks Check the pump pressure and cutoff function Pre...

Page 10: ...ve kit includes PD Timer cordset 2182602U 2182604U 10 Pump elbow 2256 11 Connector tube assembly 8 5394 12 Motor PSC 21805U Item Description Part Number 13 Blower wheel use only RWB replacement 2459U...

Page 11: ...ith the unit or controls Call your qualified service agency Incorrect operation of the burner could result in severe personal injury death or substantial property damage The following could result in...

Page 12: ...near the heating appliance there are no signs of oil or water leakage around the burner or appliance Weekly Check your oil tank level Always keep your oil tank full especially during the summer in ord...