Safety instructions

The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury.

Instructions for the user

General information

All work, including maintenance and cleaning, on electrical installations as well as other system parts
must always be performed by authorised specialists, in particular qualified electricians.

Children from the age of 8 years and persons with reduced physical, sensory or mental capabilities or
lack of experience and/or knowledge may use these devices, provided they are supervised or have
been instructed in the safe use of the device, and have understood the hazards involved. Children must
not play with the device.

Systems have to be checked regularly by authorised specialists for wear and damage.

Always put damaged systems out of operation immediately until they are repaired by an authorised
specialist.

Do not operate equipment if people or objects are within the danger zone.

Observe the danger zone of the equipment during operation.

Stop and disconnect the equipment from the mains power supply when maintenance and cleaning is
being performed either on the system itself or in the immediate vicinity of it.

Ensure that there is adequate clearance (at least 40 cm) between moving parts and adjacent objects.

Caution

Safety instructions for avoiding serious injuries.

Crushing or shearing points must be avoided or protected.

Instructions for installation and commissioning

General information

Observe the safety instructions in EN 60335-2-97. Please note that this list of safety instructions is not
exhaustive, since it would be impossible for the standard to include all sources of danger. For example,
the design of the operated product, the way the drive works in the situation it is installed in or even the
way the end product is mounted in the end user's place of use cannot be taken into consideration by
the drive manufacturer. 
If any questions or uncertainties regarding the safety instructions contained in the standard arise,
please contact the manufacturer of the part or end product in question.

All applicable standards and regulations for electrical installation must be complied with.

All work, including maintenance and cleaning, on electrical installations as well as other system parts
must always be performed by authorised specialists, in particular qualified electricians.

Only use spare parts, tools and accessory devices which have been approved by the drive manufac-
turer. 
Unapproved third-party products or modifications to the system and its accessories represent a risk to
your safety and the safety of others. This means that the use of unapproved third-party products, or
modifications which have not been agreed with or approved by us, are prohibited. We do not accept li-
ability for damage or injury arising from such actions.

Position control devices within sight of the driven product, but away from moving parts, at a height of
over 1.5 m.

Permanently mounted control devices must be positioned where they can be seen.

Rated torque and duty cycle must be suitable for the requirements of the driven product. 
Technical data – rated torque and service life can be found on the type plate of the tubular drive.

4

Summary of Contents for R12/17RO+

Page 1: ...s for roller shutters Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com 2010 300 443 0f 25 08 2016 ...

Page 2: ...ssembling the drive adapter with separate drive adapter safety catch 9 Assembling and disassembling the drive adapter with screw connection 9 Securing the drive against axial displacement 9 Fixing the drive adapter to the barrel dia 45 10 Mounting the drive in the tube 10 Setting the limit positions 12 Deleting the limit positions with a rotary switch or a locking button 12 Deleting the limit posi...

Page 3: ...lling and setting the equipment The date of manufacture comes from the first four digits of the serial number The numbers 1 and 2 indicate the year and the numbers 3 and 4 indicate the calendar week Example 24th calendar week in 2012 Ser No 1224XXXXX Explanation of pictograms CAUTION CAUTION indicates a hazardous situation which if not avoided could result in injury ATTENTION ATTENTION indicates m...

Page 4: ...nstructions in EN 60335 2 97 Please note that this list of safety instructions is not exhaustive since it would be impossible for the standard to include all sources of danger For example the design of the operated product the way the drive works in the situation it is installed in or even the way the end product is mounted in the end user s place of use cannot be taken into consideration by the d...

Page 5: ...trical or electronic equipment and units are operated certain components e g the power supply unit are live Physical injuries or damage to property can result in the event of unauthorised interventions or failure to heed warnings Be careful when touching the tubular drive as it heats up during operation for technolo gical reasons Before installation shut down all lines and control devices that are...

Page 6: ...order to protect the safety of the users and others since these ac tions can impair the system s safety and carry the risk of personal injury and property damage The drive manufacturer does not accept liability for damages or injury arising from such actions Always observe the information in these instructions when operating or repairing the system The drive manufacturer does not ac cept liability...

Page 7: ...bly the power supply to the connecting cable must be disconnected Insert a suitable flathead screwdriver right into the recess of the locating latch so that the latch releases the locating lug from the plug Now you can pull out the connecting cable along with the flathead screwdriver A A locating latch 7 ...

Page 8: ... L of the barrel L X M G The space required at the side M varies depending on the combination of drive and wall bracket Then mount the wall bracket and idler Ensure that the barrel is aligned at right angles to the wall and that sufficient axial play is al lowed for the mounted system Attention When using rigid shaft connectors closed brackets must be fitted The tubular drive presses the closed cu...

Page 9: ... disassembling the drive adapter with separate drive adapter safety catch Assembling and disassembling the drive adapter with screw connection Securing the drive against axial displacement 10 mm In order to secure the drive against axial displacement we recommend screwing the drive adapter to the tube Attention When drilling into the barrel never drill near the tubular drive 9 ...

Page 10: ...ugs which are used to assist fitting on the thrust ring the bar rel must be connected to the thrust ring by a 4 8 x 9 5 mm self tapping screw Assemble the tubular drive with the relevant thrust ring 1 and drive adapter 2 In sert the tubular drive with the pre assembled thrust ring and drive adapter into the tube to achieve a form fit Ensure that the thrust ring and drive adapter are secure in the ...

Page 11: ...t three for longer tubes use three springs anti lifting devices per meter of barrel Lay the connecting cable Lay the connecting cable up to the tubular drive and fix The connecting cable and any antennae must not project into the winding chamber Cover any sharp edges 11 ...

Page 12: ... tubular drive has turned off automatically in the desired position three times Note on roller shutter use If the tubular drive switches off prematurely while opening or closing due to an obstruc tion the obstruction can be cleared by reversing a short way and removing the obstruc tion The desired limit position can be set by opening closing again Attention Compliance with the following order for ...

Page 13: ...lick click sound to confirm Both limit positions are deleted Obstruction detection Blockage detection Caution Use of the drive s obstacle detection system as personal protection is not permitted It has been designed exclusively to protect the roller shutters or sun protection system from be ing damaged If the drive is correctly installed it switches off when it detects obstructions or shutter faul...

Page 14: ...in the same system The changeover time for switching the running direction must be at least 0 5 s The switch and control must not execute simultaneous UP and DOWN com mands Protect the electrical connections from damp Once you have finished wiring everything to the control ALWAYS check the right direction assignment of the drive to the control buttons UP and DOWN EXTEND and RETRACT If the drive is...

Page 15: ...he tubular drive Check electrical installation remove any external devices re programme limit po sitions Due to long cable L1 and N connection have been reversed Change around L1 and N N blue L1 black brown re programme limit posi tions Tubular drive stops arbitrarily cannot be restarted in the same direction Tubular drive is overloaded Use a more powerful tubular drive Roller shutter curtain keep...

Page 16: ...ck and brown wires according to the direction of travel is de pendant on how the drive is installed mounted to the right or to the left Controlling one several drive s via a single switch button Electronic black brown blue green yellow Electronic 16 ...

Page 17: ...dual control using Centronic UnitControl UC42 Mains 230 V 50 Hz Central Group Individual Individual 230 V 50 Hz Central cable connection to further control units 230 V 50 Hz 230 V 50 Hz Electronics 230 V 50 Hz Control unit 17 ...

Page 18: ...Declaration of conformity 18 ...

Page 19: ...19 ...

Page 20: ......

Reviews: