Becker P9/16PS Assemble And Operating Instructions Download Page 5

5

1

2

3

Attention
Drives from Becker Antriebe are to be mounted and operated 

solely with mechanical accessory components shown in the 

current Becker product catalogue.

The assembler must check in advance that the resistance of the brickwork or 
sunshade system meets requirements (torque of the drive plus weight of the 
shutter curtain).

Caution
Electrical connections may only be carried out by a qualified 

electrician.  Prior  to  assembly,  the  power  supply  should  be 

disconnected. Please give the enclosed connection informa-

tion to the electrical fitter carrying out the work.

1.  Establish the room required at the side for mounting (M) of the head piece, 

thrust bracket and motor bracket (Fig. 1), in order to calculate the required 
length of roller tube. The internal dimension of the roller shutter box or 
sunshade system (X) minus the overall length of wall head piece 
(M) and thrust bracket (T) gives the length (L) of the roller tube:

 

L=X-(T+M) (Fig. 2).

 

Measure the distance from the wall bracket and connecting head since 
this can vary according to the combination of motor and bracket.

2.  Then fix wall and thrust bracket.
 

Please observe the following when assembling the drive:

•  Assembly of the drive adapter with locking device:

 

You can see how to insert the locking device from its shape. When insert-
ing the locking device, ensure that the catch locks into place. You will hear 
a click. Check that the locking device is in position properly by pulling on 
the drive adapter (Fig. 3).

Intended use

Tubular drives of the 

types P3/30PS - P9/16PS 

are designed for operating awnings, screens and winter garden shades only.

Use in coupled systems is only possible if all subsystems are fully synchronised and reach the end limits at the same time.
Other applications, utilisation and modifications are not permitted in order to protect the safety of the users and others, since 
these actions can impair the system’s safety, resulting in personal injuries and property damage. Becker-Antriebe shall not 
accept liability for damages arising from such actions. Always observe the information in these instructions when operating or 
repairing the system. Becker-Antriebe shall not accept liability for damages resulting from incorrect usage.

Mounting and installation instructions

Drive adapter with locking device

4

3.  Before fitting in the barrel, take the measurement from barrel end to the 

centre of the drive adapter and mark on the barrel (Fig. 4).

Summary of Contents for P9/16PS

Page 1: ...www becker antriebe com P3 30PS P9 16PS Assembly and Operating Instructions Tubular drives for sunshades en Important information for Fitters Electricians Users Please forward accordingly These instru...

Page 2: ...ectronics using end stop systems No need to adjust end limits changes to canopies curtains are automatically compensated for using the end stop systems Safety shutdown in accordance with European engi...

Page 3: ...ided injuries may result Important safety instructions for the user Caution Failure to observe these instructions can lead to serious injuries All operational work including maintenance and cleaning o...

Page 4: ...cts or modifications which have not been agreed with or approved by us are prohibited We do not accept liability for damages or injury arising from such actions Before installation shut down all lines...

Page 5: ...cket Please observe the following when assembling the drive Assembly of the drive adapter with locking device You can see how to insert the locking device from its shape When insert ing the locking de...

Page 6: ...vant ring A and drive adapter B Insert the tubular drive with the pre assembled ring and drive adapter into the tube as shown Ensure that the ring and drive adapter are correctly positioned in the tub...

Page 7: ...le leads of the tubular drive to those of the switch control set product no 4901 002 181 0 or of the operator s control according to the colour coding and switch on the power supply a Point when canop...

Page 8: ...f automatically The end limits are set Deleting the end limits using the switches a Deleting the end limits individually Note Itisonlypossibletodeleteanindividuallimitstopifthepointwhen the canopy is...

Page 9: ...both switches to the program ming position Move the canopy to the required end limit when the canopy is extended 2 Press the programming button 1 of the setting controls for 3 seconds This is acknowl...

Page 10: ...tion Move the canopy to the required end limit when the canopy is extended 2 Press the programming button 1 of the setting controls for 3 seconds This is acknowledged by a click of the tubular drive T...

Page 11: ...clack sound to confirm The final position has been deleted b Deleting both final positions Move the canopy to the final position which is to be deleted Move the canopy to a position be tween both fin...

Page 12: ...he changeover time for changing the running direction must be at least0 5 s Switch and control must not execute simultane ous UP and DOWN commands To operate drives with electronic limit switching onl...

Page 13: ...ain after a few minutes 2 Tubular drive is faulty does not work even after standing still for a long period of time 2 Replace the drive carry out RESET with the programming pushbutton No click may be...

Page 14: ...perating Instructions Sample wiring diagrams Controlling one several drive s via a single switch button Central group and individual control using Centronic UnitControl UC42 Subject to technical chang...

Page 15: ...15 Declaration of conformity...

Page 16: ...2010 300 246 0f 03 12...