Becker P9/16PS Assemble And Operating Instructions Download Page 13

13

What to do if...?

Problem

Cause 

Remedy

Tubular drive overruns 
the end limit or does 
not reach the set end 
limit..

1.  A short circuit caused by dampness.

1.  Investigate source, dry out the system and 

reprogramme.

2.  External devices are connected to the power 

leads of the tubular drive.

2.  Check electrical installation, remove ex-

ternal device if connected, reprogramme 
system.

3.  L1 and N connection have been reversed.

3.  Exchange L1 and N (N = blue, L1 = black/

brown), reset the end limits.

4.  End stops have become detached or one or 

more suspension devices have broken.

4.  Repair system; reset tubular drive, then 

reset the end limits.

The tubular drive does 
not retract after setting 
the extended limit stop.

The tubular drive has been accidentally extend-
ed further and switches off automatically.
Both end limits have now been set in the tubular 
drive.

Delete the limit stops, reset the outer end limit 
and immediately retract.

Tubular drive stops 
arbitrarily, impossible 
for it to move further in 
the same direction.

1.  Tubular drive is overloaded.

1.  Use a more powerful tubular drive.

2.  Sunshade system keeps jamming, friction is 

too high.

2.  Ensure that the sunshade system runs 

smoothly.

3.  Fitting a tubular drive which has end limits 

already programmed.

3.  Delete the end limits and reinstall them.

Tubular drive does not 
run in the direction 
required.

1.  Tubular drive is overheated.

1.  The tubular drive is operational again after a 

few minutes.

2.  Tubular drive is faulty (does not work even 

after standing still for a long period of time).

2.  Replace the drive; carry out RESET with the 

programming pushbutton. No click may be 
heard (emergency programme), tubular 
drive can be moved up and down using the 
setting controls for the purpose of dismoun-
ting the drive.

3.  Tubular drive switched off when it encounte-

red an obstacle the last time it moved in the 
same direction.

3.  Move the curtain or canopy away from the 

obstacle, remove the obstacle and set the 
drive to move in the direction required.

4.  Electrical connection faulty.

4.  Check the electrical connection.

Tubular drive only runs 
for approx. 5 secs.

Tubular drive is in error mode (obstacle recog-
nition malfunctioning).

Reset the end limits or replace the tubular drive.

When you attempt to 
set the end limits using 
the setting controls, 
this does not work.

The end limits have already been set using the 
switches.

Move both switches to the reset position.
Press the control command briefly.
Move both switches to the programming posi-
tion simultaneously.
Reset the end limits using the setting controls.

When you attempt to 
set the end limits using 
the switches, this does 
not work.

The end limits have been reached more than 16 
times.

Move both switches to the reset position.
Press the control command briefly.
Reset the end limits.

Tubular drives switches 
off automatically be-
fore programming the 
desired 1. Final posi-
tion (final position of 
extention).

Drive has recognized an increase in torque.

1.  Drive past this position.
2.  Push the Reset-button while being at this 

position.

Summary of Contents for P9/16PS

Page 1: ...www becker antriebe com P3 30PS P9 16PS Assembly and Operating Instructions Tubular drives for sunshades en Important information for Fitters Electricians Users Please forward accordingly These instru...

Page 2: ...ectronics using end stop systems No need to adjust end limits changes to canopies curtains are automatically compensated for using the end stop systems Safety shutdown in accordance with European engi...

Page 3: ...ided injuries may result Important safety instructions for the user Caution Failure to observe these instructions can lead to serious injuries All operational work including maintenance and cleaning o...

Page 4: ...cts or modifications which have not been agreed with or approved by us are prohibited We do not accept liability for damages or injury arising from such actions Before installation shut down all lines...

Page 5: ...cket Please observe the following when assembling the drive Assembly of the drive adapter with locking device You can see how to insert the locking device from its shape When insert ing the locking de...

Page 6: ...vant ring A and drive adapter B Insert the tubular drive with the pre assembled ring and drive adapter into the tube as shown Ensure that the ring and drive adapter are correctly positioned in the tub...

Page 7: ...le leads of the tubular drive to those of the switch control set product no 4901 002 181 0 or of the operator s control according to the colour coding and switch on the power supply a Point when canop...

Page 8: ...f automatically The end limits are set Deleting the end limits using the switches a Deleting the end limits individually Note Itisonlypossibletodeleteanindividuallimitstopifthepointwhen the canopy is...

Page 9: ...both switches to the program ming position Move the canopy to the required end limit when the canopy is extended 2 Press the programming button 1 of the setting controls for 3 seconds This is acknowl...

Page 10: ...tion Move the canopy to the required end limit when the canopy is extended 2 Press the programming button 1 of the setting controls for 3 seconds This is acknowledged by a click of the tubular drive T...

Page 11: ...clack sound to confirm The final position has been deleted b Deleting both final positions Move the canopy to the final position which is to be deleted Move the canopy to a position be tween both fin...

Page 12: ...he changeover time for changing the running direction must be at least0 5 s Switch and control must not execute simultane ous UP and DOWN commands To operate drives with electronic limit switching onl...

Page 13: ...ain after a few minutes 2 Tubular drive is faulty does not work even after standing still for a long period of time 2 Replace the drive carry out RESET with the programming pushbutton No click may be...

Page 14: ...perating Instructions Sample wiring diagrams Controlling one several drive s via a single switch button Central group and individual control using Centronic UnitControl UC42 Subject to technical chang...

Page 15: ...15 Declaration of conformity...

Page 16: ...2010 300 246 0f 03 12...

Reviews: