Adjusting the limit positions with a rotary switch or a locking button
Intelligent installation management
Completion of installation following automatic setting of limit position "Stop"
The drive saves the limit position "Stop" permanently once the it has been reached 3 times in succession. Installation is then com-
plete.
Limit position status indicator
A brief stopping and restarting indicates that no limit position has been set in that direction of movement.
If the tubular drive switches off prematurely while opening or closing due to an obstruc-
tion, the obstruction can be cleared by reversing a short way and removing the obstruc-
tion. The desired limit position can then be set by opening/closing again. A reduced torque
in the direction of travel only occurs after the upper limit position has been set. The dis-
tance from the upper stop is automatically cyclically checked and, if necessary, corrected.
Move 3x in succession to the permanent upper stop from a distance of > 300 mm
without interruption.
▻
The tubular drive confirms after the limit position has been approached three
times. The limit position is then shifted approx. 10 mm before stopping.
Move 3x in succession to the permanent lower stop from a distance of > 300 mm
without interruption.
▻
The tubular drive confirms after the limit position has been approached three
times. The limit position is then shifted approx. 20 mm before stopping.
►
The limit positions are now set.
Deleting the limit positions with a rotary switch or a locking button
The switching commands sequence must be carried out in quick succession.
Carry out the following deletion sequence without interruption between the individual drive commands:
until
STOP
The tubular drive acknowledges.
Both limit positions are deleted.