Deleting both limit positions
Any additional functions that may have been set are deleted at the same time, or are reset
to the factory default settings.
Open/close the shading solution to a point between the limit positions.
Press the programming button and keep it pressed.
Then press down the travel button and keep it pressed.
Now release the programming button, but continue to keep the travel button pressed.
Next press the programming button again.
▻
The tubular drive confirms.
►
Both limit positions are deleted.
Setting the limit positions with Auto-Install
Intelligent installation management
Completion of installation following automatic setting of limit position "Stop"
Next time the “stop” limit position is travelled to, this position will be provisionally saved as the limit position. Once the limit position
has been detected at this position 3 times in a row without any problems, it will be definitively saved. This normally takes place dur-
ing regular operation.
To complete installation quickly, it is sufficient to travel to the “stop” limit position 3 times in a row from approx. 20 cm.
Limit position status indicator
A brief stopping and restarting indicates that no limit position has been set in that direction of movement.
Setting the limit positions
There are several ways to set the limit positions:
•
Start point to retracted stop
•
Auto point to retracted stop (only with articulated-arm awnings)
These settings can be programmed using a suitable operating control, e.g. a rotary switch,
programming unit etc.
These tubular drives are designed for short-time operation (for the operating mode,
please see technical data).
The number of cycles an awning is capable of depends on the barrel diameter and awning
extension.
The drive running time is cut short if the drive has not cooled down fully after the previous
use.