Deleting the limit positions using the programming unit
Connect the wires of the tubular drive to those of the same colour in the programming unit
and switch on the power supply.
Please pause for 1 sec after the last drive command before beginning the deletion se-
quence. Also leave a pause of 1 sec between the individual steps of the deletion sequence.
Deleting a limit position when 2 limit positions are programmed
Any additional functions that have been set are retained.
black
brown
blue
green-yellow
black
brown
blue
green-yellow
Programming button
Travel button
Open/close to the limit position to be deleted.
Press the programming button and keep it pressed.
Then press down the travel button and keep it pressed.
Now release the programming button, but continue to keep the travel button pressed.
Next press the programming button again.
▻
The tubular drive confirms.
►
The limit position is now deleted.