background image

Explanation of pictograms

CAUTION

CAUTION indicates a hazardous situation which, if not avoided, could
result in injury.

ATTENTION

ATTENTION indicates measures that must be taken to avoid damage to
property.

Denotes user tips and other useful information.

Warranty

Structural modifications and incorrect installation which are not in accordance with these and our other instructions can result in
serious injuries, e.g., crushing of limbs. Therefore, structural modifications may only be carried out with our prior approval and
strictly in accordance with our instructions, particularly the information contained in these Assembly and Operating Instructions.
Any further processing of the products which does not comply with their intended use is not permitted.
The end product manufacturer and fitter have to ensure that all the relevant current statutory, official and, in particular, EMC regu-
lations are adhered to during utilisation of our products, especially with regard to end product manufacture, installation and cus-
tomer advice.

Safety instructions

The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury.

Instructions for the user

General information

All work, including maintenance and cleaning, on electrical installations as well as other system parts
must always be performed by authorised specialists, in particular qualified electricians.

Children from the age of 8 years and persons with reduced physical, sensory or mental capabilities or
lack of experience and/or knowledge may use these devices, provided they are supervised or have
been instructed in the safe use of the device, and have understood the hazards involved. Children must
not play with the device.

Systems have to be checked regularly by authorised specialists for wear and damage.

Always put damaged systems out of operation immediately until they are repaired by an authorised
specialist.

Do not operate equipment if people or objects are within the danger zone.

Observe the danger zone of the equipment during operation.

Stop and disconnect the equipment from the mains power supply when maintenance and cleaning is
being performed either on the system itself or in the immediate vicinity of it.

Ensure that there is adequate clearance (at least 40 cm) between moving parts and adjacent objects.

Caution

Safety instructions for avoiding serious injuries.

Crushing or shearing points must be avoided or protected.

Instructions for installation and commissioning

General information

Observe the safety instructions in EN 60335-2-97. Please note that this list of safety instructions is not
exhaustive, since it would be impossible for the standard to include all sources of danger. For example,
the design of the operated product, the way the drive works in the situation it is installed in or even the
way the end product is mounted in the end user’s place of use cannot be taken into consideration by

4

Summary of Contents for L120/11C PS(+)SMI

Page 1: ...structions SMI Rohrantriebe Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebe...

Page 2: ...ing the drive adapter with drive adapter safety catch 9 Assembling the drive adapter with screw connection 9 Securing the drive against axial displacement 9 Fixing the drive adapter to the barrel dia...

Page 3: ...SMI actuators made by the drive manufacturer For plug in connecting cable PS SMI Optimised for sun protection applications Installation without stops is possible from extended point to retracted point...

Page 4: ...cialists in particular qualified electricians Children from the age of 8 years and persons with reduced physical sensory or mental capabilities or lack of experience and or knowledge may use these dev...

Page 5: ...er surface from which access to the drive is gained To ensure safe operation of the system after commissioning the limit positions must be correctly set programmed in Drives with a H05VV F connecting...

Page 6: ...s at the same time The type of tubular drive has been designed particularly for the operation of cassette awnings with a higher requirement for closing torque clean closure of the cassette For roller...

Page 7: ...he two plug grooves provided for this purpose Check that the cable is properly engaged 1 locating lug Disassembling the plug in connecting cable for tubular drives dia 35 Caution Prior to disassembly...

Page 8: ...fitter must ensure that the masonry and the system being motorised are sufficiently robust drive torque plus weight of the shading solution Caution Electrical connections may only be carried out by a...

Page 9: ...drive adapter 1 onto the drive shaft of the tubular drive You can see which way to insert the safety catch 2 from its shape When inserting the drive adapter safety catch 2 into the hole 4 make sure th...

Page 10: ...n the tube For profile tubes In the case of some drive adapters tolerances of the groove widths in different bar rels can be offset by rotating the drive adapter into a different groove recess These g...

Page 11: ...s Attention If the allocation table for the SMI tubular drives is incorrect or not available commission ing of the KNX SMI actuator is not possible Connection to the programming unit green yellow blue...

Page 12: ...been set It may be necessary to delete both limit positions in order to change the direction of rotation There are 4 ways to set the limit positions Lower point to upper point not the stops Lower poin...

Page 13: ...sound to confirm The limit positions are now set Lower point to upper stop Close to the desired lower limit position Press the programming button of the programming unit for 3 seconds The tubular driv...

Page 14: ...t be switched Proceed as follows Switch the direction switch 1 to the opposite position The running direction will now have changed Check the running direction again It is only possible to change the...

Page 15: ...to the desired retracted limit position Press the programming button of the programming unit for 3 seconds The tubular drive makes a click sound to confirm The limit positions are now set Extended pos...

Page 16: ...n sequence Deleting a limit position when 2 limit positions are programmed green yellow blue brown black grey green yellow blue brown black grey Programming button Travel button Open close to the limi...

Page 17: ...he programming button and keep it pressed Then press down the travel button and keep it pressed Now release the programming button but continue to keep the travel button pressed Next press the program...

Page 18: ...imit position and retract immedi ately Tubular drive stops arbitrarily cannot be restarted in the same direction Tubular drive is overloaded Use a more powerful tubular drive Sun protection system kee...

Page 19: ...system The changeover time for switching the running direction must be at least 0 5 s The switch and control must not execute simultaneous UP and DOWN com mands Protect the electrical connections from...

Page 20: ...current con sumption A 0 45 0 50 0 75 0 90 1 18 1 10 Mode S2 4 min Degree of protection IP 44 Min tube inside dia meter mm 47 Emission sound pres sure level dB A 70 Technical data dia 58 Type L50 17C...

Page 21: ...eter mm 60 Emission sound pres sure level dB A 70 This tubular drive is not yet available Sample wiring diagram Controlling one several drive s via a single KNX SMI actuator Central control of up to 8...

Page 22: ...stallation Direction of rotation as signed limit positions pro grammed Manufacturer s code 2 Becker Antriebe GmbH Project customer Room Signature Project manager building contractor Signature Installi...

Page 23: ...Declaration of conformity 23...