Anti-lifting device in the lower limit position to upper point without stop
Move down to the lower limit position.
▻
The tubular drive switches off automatically.
Then move to the desired upper limit position.
Press the programming button of the programming unit for 3 seconds.
▻
The tubular drive makes a “click” sound to confirm.
►
The limit positions are now set.
Adjusting the PS(+)SMI limit positions
Check the assignment of the direction of rotation before positioning the limit stops.
Press the retract or extend button.
▻
The shading solution runs in the desired direction.
►
The running direction is OK.
If the shading solution runs in the wrong direction, the running direction must be switched. Proceed as follows:
Switch the direction switch (1) to the opposite position.
►
The running direction will now have changed.
Check the running direction again.
It is only possible to change the direction of rotation if no limit position has been set. It may
be necessary to delete both limit positions in order to change the direction of rotation.
There are 2 ways to set the limit positions:
•
Extended position to retracted position without stop
•
Extended position to retracted stop
The limit position becomes fixed after the tubular drive has turned off automatically in the desired position three times.
If the tubular drive switches off prematurely while extending/retracting, due to an obstruc-
tion, the obstruction can be cleared by extending/retracting the screen and removing the
obstruction. The upper limit position can be set by extending/retracting again.