bebob factory GmbH – Höglwörtherstr. 350 – D-81379 München – Tel.: +49 89 27818282
August 2018
•
Maximum load is 10.0A. When using the battery with video or lighting equipment, power
consumption of the equipment must be 10.0A or below. For the protection of the battery, a
load of 10.0A or over may activate the internal protection circuit and stop supply of power.
In this case the status led will turn red.
•
The battery can be used in ambient temperature of - 20°C - + 55°C.
Storage
•
Storage temperature range is - 20°C ~ + 35°C (<85% humidity).
•
To store the battery for a long period (longer than 4 Weeks), the battery should be charged
between 50% and 75%. The battery should be recharged every 4 Weeks.
•
After storage some self-discharge will occur. Before re-use it is advisable to recharge the
battery fully.
Camera Data Communication
•
Blue leds: Arri/Sony Data Protocol
•
Red leds: Red Data Protocol
•
To switch between both status, press the Check button for 5s
Status led
•
Status led lighting Green: Full Capacity over 70% of New
•
Status led lighting Yellow: Full Capacity between 50% and 70% of New
•
Status led lighting Red: Full Capacity under 50% of New
Flash Light
•
To switch On/Off press the Check Button Twice