beautyrest Black Luxury Base Owner'S Manual Download Page 4

2

IN-HOME USE AND HOSPITAL STANDARDS:

Ergomotion adjustable bed bases are designed solely for in-home use. This 

base was not designed as a hospital bed and is not designed to meet hospital 

standards. Do not use this base with TENT TYPE oxygen therapy equipment or 

near explosive gases.

ADDITIONAL SAFETY FEATURES

Casters (optional leg accessory) are equipped with locking wheels to prevent 

unwanted movement. Even when locked and unable to roll, it is possible for 

the casters to slide. Free release head and foot motors are designed to lower 

the mattress by retracting only with gravity, never pulling downwards, which 

minimizes pinch points.

ACOUSTICS

LIFTING/LOWERING MECHANISMS 

The lift/lower feature will emit a minimal humming sound during operation. This 

is normal. During operation, the lift arm wheels make contact with the platform 

support of the base.  This contact may result in metal on metal or metal on plastic 

contact. This applies slight tension on the moving components and resonance 

is reduced to a minimum level. If excessive noise or vibration is experienced, 

reverse the movement action (up or down) of the base with the remote control. 

This should realign the base’s activating mechanisms to the proper operational 

position.  In normal base operation, the wheels which allow the bed to maintain 

its distance from the wall, will make contact with the steel platform supports of 

the base creating a contact noise. When entering, exiting or shifting weight on 

the base, this contact noise may be audible as the wheels make contact. This is 

normal.

MATERIALS

Ergomotion adjustable bases are constructed from various materials including 

woods, metals, plastics and fabrics. Tension, pressure or movement applied to 

the frame, platform or shroud through general use may create an audible sound.

MASSAGE OPERATION AND LOCATION ENVIRONMENT

The massage feature will emit a tone during operation. This is normal. As the 

massage intensity level is increased, the tone will intensify. The volume of 

this tone is directly related to the location environment. For example, when 

demonstrated in a show room, the surrounding environmental noise will cover 

some of the massage noise. However, when installed in a home setting with 

wooden floors, carpeted or not, the massage volume will be more noticeable. To 

minimize this resonance, place a piece of carpet, or rubber caster cups, under 

each leg or caster of the base.  It is possible to experience vibration or noise 

from the exterior bed frame, headboard brackets, headboards or footboards if 

mounting bolts are not firmly tightened.

Levels 1-6 of massage intensity represent the revolutions of the motor per 

minute. Level 6 provides the maximum number of RPMs.  However, this does not 

mean that the feeling of vibration is the strongest.  Depending on the mattress 

material, thickness, and positioning of the user, the feeling of vibrations will differ. 

We encourage the user to find the massage intensity setting that suits them best. 

It is important to understand the physics of vibrations. Just as an engine may run 

rough during idle, as the RPMs increase, the vibrations change concurrently.  

TOLERANCE

All Ergomotion adjustable foundations, depending on make and model, are 

safety precautions and usage statements

WARNING

For optimal safety and operation, plug bed base into a surge protector 

(not included). The bed base should only be plugged directly into a 

grounded wall outlet or surge protector (strongly recommended). Improper 

connection of the equipment can result in the risk of electrical shock, 

electrical file or faulty operation of this bed base. If the plug does not fit 

your outlet, contact a qualified Electrician to install a suitable outlet.

Summary of Contents for Black Luxury Base

Page 1: ...Luxury Base OWNER S MANUAL Actual product appearance and functionality may vary from photographs illustrations and descriptions included in this manual ...

Page 2: ...5 Base Overview Quick Reference Guide 6 7 Installation Guide 8 9 Remote Control 10 11 Remote Control Preset Programming 12 Remote Control Pairing 13 Syncing Two Bases 14 Power Down Box 15 Connecting Straps 16 Headboard Brackets 17 Troubleshooting 18 Español 19 24 Notes 25 32 ...

Page 3: ...rge protector could void the electrical portion of your warranty PETS AND CHILDREN Immediately dispose of all packing materials as it may pose a smothering risk to small children and pets To avoid injury it is not advised to allow children and small pets to play on or under the bed Children should not operate the bed base without adult supervision PACEMAKERS Some products contain Neodymium MAGNETS...

Page 4: ... shroud through general use may create an audible sound MASSAGE OPERATION AND LOCATION ENVIRONMENT The massage feature will emit a tone during operation This is normal As the massage intensity level is increased the tone will intensify The volume of this tone is directly related to the location environment For example when demonstrated in a show room the surrounding environmental noise will cover ...

Page 5: ...th a light damp sponge or vacuum with a soft brush attachment to remove particles Keep at a minimum of 30cm 12 inches away from direct heat sources For a deeper cleaning blot liquid spills with a clean dry cloth Wipe with a clean cloth dampened with warm water Do not wet excessively A soft bristle brush may be used to remove ingrained soil Avoid scratching by gentle brushing Wipe with a clean clot...

Page 6: ...ble base has been delivered DON T Sit on corners edges of base this may warp the frame struts or foam Tilt the base on its side This can damage the legs and or leg screws Stand or jump on the adjustable base at any time this can damage the frame and motors Drag the base to move it Dragging the base could damage the frame strip the nut bolts or break the legs Purchase castors if you plan on moving ...

Page 7: ... Sync Cord H Connecting Strap I Manual J Warranty Card K Quick Start Guide L Divided King Quick Start Guide Misc Parts not included Surge Protector 9 Volt Batteries These items are attached to the base for shipping purposes Carefully remove from base and set aside Only included in Twin Long and Cal King Split bases Before discarding the packing materials ensure all the parts are accounted for For ...

Page 8: ...6 base overview Head Motor Control Box USB Ports Underbed Lights Foot Motor WiFi Underbed Lights Foot Massage Motors Head Massage Motors USB Ports Lumbar Motor ...

Page 9: ...motors installed under base Power Cord Control Box Power Supply Input Cord USB USB Charger WIFI Dongle Y Cable Underbed Lighting HEAD MASSAGE FOOT MASSAGE LUMBAR TILT FOOT HEAD 1 7 8 9 10 11 2 5 6 3 4 POWER LED MULTIFUNCTION POWER RESET PAIRING LED For instructions on how to pair your base with and Alexa device please see the Alexa Setup Guide ...

Page 10: ... input Power Cord connected to Control Box s power port and plug into Power Supply To sync two bases see detailed installation instructions on page 14 To install Headboard Brackets sold separately see instructions on page 18 Locate the power down box and set it aside Be sure that it is accessible after the base is set up Uncoil the Power Cord and connect to the Power Supply Place Power Supply on t...

Page 11: ...cord into a power source A surge protector is recommended Quickly test remote functions to verify proper setup before placing mattress on base Return the base to a flat position before placing the mattress on top Setup is now complete Test all functions on remote For instructions on how to pair your base with an Alexa device please see the Alexa Setup Guide Install mattress retainer bars by insert...

Page 12: ... 6 massage intensities The FOOT button will turn on the foot massage Cycle through 6 massage intensities The MASSAGE ALL OFF button will turn off massage MASSAGE FEATURE Remote Control arrives paired to the adjustable base Three 3 AAA batteries are required to operate the remote ...

Page 13: ...lieve pressure off the lower back and promote circulation Use to turn the Underbed Lighting ON OFF Lumbar Support UP Increases the level of lumbar support Lumbar Support DOWN Decreases the level of lumbar support The HEAD arrows lift and lower the head section of the base The FOOT arrows lift and lower the foot section of the base One touch FLAT preset position ONE TOUCH BUTTONS ADJUST ...

Page 14: ...e Articulate the head and foot to your desired position Press and hold one of the preset buttons I and II for 7 seconds Position is now saved To adjust the saved position repeat steps 1 and 2 and the new position will be stored NOTE To restore the preset buttons back to their original factory settings hold FLAT and ZERO G simultaneously for at least 10 seconds The original presets will be restored...

Page 15: ...se movements please repeat the process again PAIR button Press and hold the PAIR button on the back of the remote The PAIR button will illuminate and start to flash When the PAIR button stops flashing the LED light on the control box will stop flashing Release the PAIR button STEP 1 STEP 3 STEP 2 Remote Pairing The original remote that comes in the box is already paired to the adjustable base No f...

Page 16: ... the FLAT button will re sync the mechanical positions Connect the male ends of the sync cord to the Multifuction port of each control box Check to ensure all cords are securely attached Both remotes will now operate both bases simultaneously Unplug bases from power source PERFORMANCE NOTES The system is now linked Buttons pressed on either remote will control both bases simultaneously HEAD MASSAG...

Page 17: ...e system will continue to draw power from the batteries even if not in use Connect the end of the Battery Backup Strap to the input power cord that is attached to the control box STEP 3 STEP 1 STEP 2 Control Box Input Cord Battery Backup Strap Connect the Battery Backup Strap to the 2 Alkaline 9 Volt batteries Do not mix brand name Batteries HEAD MASSAGE FOOT MASSAGE LUMBAR TILT FOOT HEAD 1 7 8 9 ...

Page 18: ...ap onto leg bolt Swing the strap and connect side b to the leg bolt Secure the strap by shifting to the left Re tighten legs Do not over tighten Use the remaining strap and repeat on other end of the base STEP 2 STEP 1 STEP 3 connecting strap optional a b Connecting straps are secured to the base frame upon delivery Legs are required for the installation of the connecting straps ...

Page 19: ...ed towards the foot of the base and use a short bolt and nut to secure the bracket Make sure the bolt is tight Attach the plastic spacer and T Bracket a Measure the distance between the mounting holes on the headboard and install the spacer and attachment plate to accommodate the headboard b To install the plastic spacer and attachment plate you will need 2 long bolts and 2 nuts Place the spacer a...

Page 20: ...operly connected Unplug the base for 1 hour to reset the electronic components Plug bed base into a different electrical outlet or test current outlet with another working appliance a grounded electrical surge protector is recommended Remove and replace full batteries in the remote control and re pair the remote to the base see page 13 If issue is not resolved by following the instructions above l...

Page 21: ...or Desfibrilador implantable o cualquier otro dispositivo sensible a los campos magnéticos Fuertemente se recomienda que los propietarios de este tipo de dispositivos médicos consulten a su médico antes de usar productos que contienen imanes de neodimio También es posible que algunos marcapasos pueden interpretar erróneamente las vibraciones opcionales de masaje de la base como el movimiento ejerc...

Page 22: ... pies para diferentes configuraciones de la plataforma de soporte del colchón será de 3 que se traduce en una tolerancia de hasta Cualquier base ajustable se considerará dentro de estas tolerancias asignadas ya que ha cumplido con los estándares de control de calidad del fabricante EL OLOR DEL NUEVO PRODUCTO Algunas personas notan un ligero olor de su nueva base ajustable puede provenir del materi...

Page 23: ...base ajustable con la cabeza y o el pie en la posición articulada Entre o salga de su cama ajustable en la posición plana horizontal Alterar con o modificar la base Esto anulará la garantía Presionar hacia abajo en la cabeza o el pie mientras los motores están funcionando puede dañar el marco y motores GUARDE ESTAS INSTRUCCIONES Cumplimiento con la FCC Este dispositivo cumple con la Parte 15 de la...

Page 24: ...ble de alimentación de entrada conectado al puerto de alimentación de la caja de control y enchúfelo a la fuente de alimentación PASO 6 Desenrolle el cable de alimentación y conéctelo a la fuente de alimentación Coloque la fuente de alimentación en el suelo y extiéndala desde la base Asegúrese de que la fuente de alimentación y todos los cables conectados estén dirigidos hacia el protector de sobr...

Page 25: ...Queen Full Full Largo o King Dividido El cable de sincronización conecta las dos cajas de control a un solo control remoto para la sincronización de dos bases PASO 1 Desconecte las bases de los tomacorrientes PASO 2 Desconecte el cable de la bacteria de Reserva de cada Caja de Control o cable splitter Recuerde esta desconexión PASO 3 Conecte el macho de cada Cable de Sincronización a la Caja de Co...

Page 26: ...tale el separador y la placa de ajuste para acomodar la cabecera b Para instalar el separador plástico y la placa de ajuste necesitará 2 tornillos largos y 2 tuercas Fije el separador y la placa en el lugar deseado y ajuste los tornillos en los huecos con la cabeza del tornillo hacia afuera Ponga los tornillos diagonalmente sobre el separador Use el socket de 9 16 14mm y la llave inglesa para ajus...

Page 27: ...produits contiennent les aimants Neodymium qui pourraient interférer avec des appareils tels que les stimulateurs cardiaques les défibrillateurs implantables et tout autre appareil sensible aux champs magnétiques Il est FORTEMENT recommandé que les propriétaires de tels appareils médicaux consultent leur médecin avant d utiliser les produits qui contiennent les aimants Neodymium Il est aussi possi...

Page 28: ...on arrière et la section plate pour les diverses configurations du matelas du support devraient être à 3 ce qui se traduit en une tolérance de jusqu à 1 L angle désigné par B dans la figure 1 entre la section plate et la section de pied pour les diverses configurations du matelas et du support devrait être à 3 ce qui se traduit en une tolérance de jusqu à 1 Toute fondation ajustable jugée compatib...

Page 29: ... endommager les pieds ou les boulons Ne vous mettez jamais debout et ne sautez jamais sur le sommier ajustable ceci peut endommager le cadre et les moteurs Ne tirez pas sur le sommier pour le déménager Ceci pourrait endommager le cadre les boulons ou casser les pieds Achetez des roulettes si vous prévoyez souvent déménager votre sommier Ne montez pas sur le sommier ajustable et n en descendez pas ...

Page 30: ...Cet appareil est conforme à la norme CNR 102 d Industrie Canada pour un environnement noncontrôlé Cet appareil doit être installé et opéré à une distance minimale de 20cm entre le transmetteur et le corps humain Cet appareil ne doit pas être co localisé ou opéré avec une autre antenne ou un autre transmetteur Pg 5 Liste de pièces Avant de jeter le matériel d emballage s assurer que toutes les pièc...

Page 31: ...ns l insertion de l écrou sur le châssis Ne pas trop serrer Les pattes 3 en 1 se détordent en sections séparées pour les options de hauteur de la patte Étape 4 Déroulez la boîte de désactivation du châssis et placez la boîte sur le sol S assurer qu elle est aisément accessible lorsque la base est tournée à la position verticale Étape 5 Déroulez la corde d entrée connectée au port d alimentation su...

Page 32: ...e secours et la télécommande seront constants puis s éteint en même temps Replacer le couvercle arrière de la télécommande La télécommande est maintenant jumelée avec la base Si la Sangle de batterie de secours n est pas disponible appuyez sur le bouton de réinitialisation situé sur le boîtier de commande Le voyant d appariement sur le boîtier de commande s illuminera Appuyez et maintenez enfoncée...

Page 33: ...nnectez l extrémité de la sangle de sauvegarde de la batterie au cordon d alimentation d entrée connecté au boîtier de commande Remarque Détachez la sangle de secours de la batterie une fois l urgence terminée car le système continuera à être alimenté par les batteries même s il n est pas utilisé Pg 18 Guide d installation des fixations de la tête de lit Les fixations de la tête de liut sont des a...

Page 34: ...e ou vérifiez le courant de la prise avec un autre appareil qui fonctionne protecteur de surtension électrique mise à la terre est recommandé Retirez et replacez les piles dans la télécommande et accoupler la télécommande à la base voir page 11 Si le problème n est pas résolu en suivant les instructions ci dessus notez le numéro de série sur la carte de garantie ou à l arrière du contrôle à distan...

Page 35: ...33 notes ...

Page 36: ... 2017 Ergomotion Inc V001 _R03 10 2018 35007100 Serial Number US Customer Service Phone US 1 888 550 3746 Fax US 1 805 979 9399 Email info ergomotion com Web www ergomotion com ...

Reviews: