Problem
Cause
Remedy
No suction power from any of
the suction points
Power supply cable
disconnected
Clogged filter
Connect the power supply cable
Replace or clean the filter
cartridge
Uninterrupted succession of
starts and stops
Check for the possible presence
of defective suction points
Replace defective inlet valve
Failure of vacuum unit to start
with only one suction point in
use
Electrical contacts defective
Check electrical contacts
on inlet valve and replace if
necessary
Low or inadequate suction
power
Clogged filter
Simultaneous use of a greater
number of inlet valves than
recommended
Partial blockage of suction
pipes
Air infiltration
Air outlet blocked
Replace or clean the filter
cartridge
Check the number of inlet valve
used
Remove any blockage of the
pipes
Check correct tightening of the
dust container
Remove any blockage in the air
outlet
Self-cleaning system does not
operate
Clock does not work
Lack of pressure
Contact the Assistance Centre
Contact the Assistance Centre