background image

BEAM

 Commercial

Operation Manual

This appliance is suitable for commenrcial use, for example in hotels, schools, 
hospitals, factories, shops, offices, and rental businesses, etc.

CAUTION:

 This appliance is not suitable for picking up hazardous dust.

 

     Read these instructions manual before using this appliance.

Summary of Contents for Commercial

Page 1: ...is suitable for commenrcial use for example in hotels schools hospitals factories shops offices and rental businesses etc CAUTION This appliance is not suitable for picking up hazardous dust Read these instructions manual before using this appliance ...

Page 2: ... Dust container 9 2 6 Central section 9 2 7 Top section 9 2 8 Safety and hazard stickers 10 3 Movement and unpacking 10 4 Installation 11 4 1 Choice of installation position for the main central vacuum unit 11 4 2 Installation of the BEAM Commercial central vacuum unit 11 4 3 Electrical connections 11 5 Use and operation 12 5 1 Switching on first time 12 5 2 Operation instructions 13 5 3 Final sys...

Page 3: ...nt or plaster or hazardous dust Do not suck up plaster cement or rubble Always disconnect the power supply at the electrical panel during installation if maintenance or repair operations are necessary if the system is not to be used for a long period Do not under any circumstances whatsoever work on the unit while it is operating Wear protective gloves and a face mask for all maintenance work empt...

Page 4: ...thout any obligation for prior notification 1 3 General safety precautions The purpose of this information is to make persons interacting with the system aware of all possible conditions of danger and thereby to avoid injuries either to themselves or to others Design for safety During the design and construction phase the manufacturer dedicated particular attention to aspects that may cause risks ...

Page 5: ...ply of spare parts customers are to contact the dealer or the distributor the identification data for the unit can be found on the rating plate Figure 1 The rating plate is located on the right hand side of the vacuum unit For all requests for technical assistance in addition to details of the problem encountered customers are asked to inform your local distributor dealer of all system information...

Page 6: ...ich the product has been designed represents improper use that may damage the vacuum unit and constitute a serious hazard for the user 2 TECHNICAL CHARACTERISTICS 2 1 Description of the BEAM Commercial central vacuum unit BEAM Commercial central vacuum units are designed and manufactured for the suction of dust both in residential buildings and in service sector premises such as hotels cinemas the...

Page 7: ...Self cleaning function no yes no yes Technical data Dimensions Container capacity L 90 90 90 90 Diameter cm 46 46 46 46 Filter surface m 2 2 2 2 Inlet outlet diameter mm 63 63 63 63 Height cm 177 177 177 177 Width cm 70 70 70 70 Depth cm 85 85 85 85 Weight kg 104 112 104 112 2 2 Standard models and approximate dimensions Figure 2 ...

Page 8: ...26A BC238M BC238A Maximum airflow m3 h 350 350 460 460 Airflow operating at 160 mBar m3 h 180 180 340 340 Operating suction pressure mBar 160 160 160 160 Noise emission dBA 63 63 68 68 Electrical technical data Motor power kW 2 6 2 6 3 8 3 8 Power supply voltage V 230 230 400 400 Power supply frequency Hz 50 60 50 60 50 60 50 60 Power absorbed A 6 7 6 7 9 7 9 7 Inverter yes yes yes yes Maximum fre...

Page 9: ...uum unit as follows Electrical control panel Inverter Main switch Self cleaning timer BC126A and BC238A Electronics board for control of the filter self cleaning function BC126A and BC238A Cartridge filter Pressure transducer for regulation of the operating suction pressure Compressor for filter self cleaning function BC126A and BC238A Compressed air tank for filter self cleaning function BC126A a...

Page 10: ...y replacement parts ATTENTION Suitable lifting equipment must be used when moving the vacuum unit and particular care must be taken to correctly balance loads The support surface must not have a slope of more than 8 to avoid the risk of overturning due to loss of stability During movement operations use appropriate items of personal protection equipment Failure to use appropriate items of personal...

Page 11: ...installation position must permit the fitting of air exhaust pipes no longer than five metres with Ø63 mm pipes After this distance Ø80 mm pipes must be used 4 2 Installation of the BEAM Commercial central vacuum unit This unit has been designed for easy and convenient installation The vacuum unit must be positioned respecting the clearance distances indicated in Figure 5 There must be a space of ...

Page 12: ...is essential to ensure that all persons who will be involved in operation of the system are suitably trained and made aware of all the information provided in this manual In particular they must be informed of the risks involved in operation of the system and of the precautions to be taken to reduce risks during operation to a minimum 5 2 Operation instructions Switching on move the main switch on...

Page 13: ...m 5 4 Operation of the inverter on the control panel On BEAM Commercial central vacuum units the inverter controls operation of the suction turbine A transducer that measures operating suction pressure is connected to the inverter Using the signals received the inverter maintains the pre set operating parameters constant increasing or reducing the rotation frequency of the turbine as the condition...

Page 14: ...the self cleaning cycle do not open the dust collector container and after the end of the cycle wait at least one minute before opening it Make annual inspections on the filter to ensure that it is undamaged and to check if it needs washing if washed the filter must be dry before being replaced 6 MAINTENANCE 6 1 Routine maintenance Accurate maintenance extends the operational life of the system an...

Page 15: ... handle provided 3 Extract the dust collection bag and replace it with a new one 4 Fold the edges of the bag towards the exterior 5 Hook up the dust container again to the separator If it is necessary to move the dust container away from the separator to empty the dust collection bag the depression pipe keeping the bag in the correct position must be disconnected 6 3 Replacement of the filter cart...

Page 16: ...l system starting While the dust container is being hooked up there is the risk of cutting injuries to the fingers Dismount the filter cartridge to be cleaned changed see details of this operation in previous section and if a replacement cartridge is available use it to replace the cartridge to be cleaned Clean the dirty cartridge with the vacuum unit using the brush accessory for corners taking c...

Page 17: ...blem Cause Remedy No suction power from any of the suction points Power supply cable disconnected Clogged filter Connect the power supply cable Replace or clean the filter cartridge Uninterrupted succession of starts and stops Check for the possible presence of defective suction points Replace defective inlet valve Failure of vacuum unit to start with only one suction point in use Electrical conta...

Page 18: ...to the risk of accidental starting or of electric shock During decommissioning operations the appropriate items of personal protection equipment must be used Failure to use appropriate items of personal protection equipment during decommissioning and dismantling operations may expose the operator to the risk of crushing of the feet due to loss of stability Failure to wear safety gloves prevents a ...

Page 19: ...19 ...

Page 20: ...20 2013 Electrolux Home Care Products Ltd Sold and serviced by For additional product information visit www beamcommercial com ...