VIO-ST

1

2

6

3

4

5

1. 

cover 

2. 

IR-prism 

(2 m)

3. 

main connector

DESCRIPTION

ENGLISH

Safety sensor 

for automatic sliding doors

4. 

IR-angle adjustment

5. 

push button for setup or DIP-setting confirmation

6. 

DIP-switch

User’s Guide for product version 0200 and higher
See product label for serial number

TECHNICAL SPECIFICATIONS

Presence
Typical response time: <256 ms
Max. presence time: 30 sec
Active infrared with background analysis
Spot diameter: 0.1 m (typ)
Number of spots: 24
Number of curtains: 2
From -4 ° to +4 ° (adjustable)
Solid-state-relay 
(free of potential, free of polarity)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
0.3 s to 1 s (not adjustable)
Typical: < 5 ms

12 V - 30 V DC -5%/+10% 

(to be operated from SELV compatible power supplies only)

< 1.6 W
1.8 m to 3 m
< 1 V : Log. L; > 10 V: Log. H (max. 30 V)
-25 °C to +55 °C
IP54
< 70 dB
20 years
EN 62061 SIL2; EN 61496-1 ESPE Type 2; EN 61000-6-2; EN 61000-6-3; EN 12978; 

EN 50581; EN 16005

EN ISO 13849-1 Pl «c»

 CAT.2 

(under the condition that the door control 

system monitors the sensor at least once per door cycle)

Supply voltage:
Power consumption:
Mounting height:
Sensitivity of the test input:
Temperature range:
Degree of protection:
Noise:
Expected lifetime:
Norm conformity:

Detection mode:

Technology:

Angle:
Output:

Hold time output signal:
Response time on test request:

Specifications are subject to changes without prior notice. All values measured in specific conditions.

Summary of Contents for VIO-ST

Page 1: ...x contact voltage 42 V AC DC 0 3 s to 1 s not adjustable Typical 5 ms 12 V 30 V DC 5 10 to be operated from SELV compatible power supplies only 1 6 W 1 8 m to 3 m 1 V Log L 10 V Log H max 30 V 25 C to 55 C IP54 70 dB 20 years EN 62061 SIL2 EN 61496 1 ESPE Type 2 EN 61000 6 2 EN 61000 6 3 EN 12978 EN 50581 EN 16005 EN ISO 13849 1 Pl c CAT 2 under the condition that the door control system monitors ...

Page 2: ...door control unit and the door cover profile must be correctly earthed SENSOR H W 2 20 m 2 30 m 2 50 m 2 55 m 3 00 m 2 80 m H W 2 20 m 1 20 m 2 50 m 1 40 m 3 00 m 1 60 m 2 2 m Depth of curtain 8 10 cm Depth of safety field 25 cm RELAY R1 RELAY R2 12 30 V DC Check position of IR curtains with Spotfinder and adjust if necessary DOOR Detection field width indicated according to conditions defined in ...

Page 3: ...aving the premises The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety and if applicable the machinery directive 2006 42 EC The device cannot be used for purposes other than its intended use All other uses cannot be guaran...

Page 4: ...ED signal The ORANGE LED flashes quickly The sensor signals an internal fault Irregularities in the power supply The sensor receives not enough IR energy The sensor receives too much IR energy The sensor encounters a memory problem The sensor vibrates The sensor sees the door during the assisted setup The sensor sees the door The sensor is disturbed by lamps or another sensor The sensor is disturb...

Reviews: