MOUNTING & WIRING

INFRARED FIELD - SAFETY

GREEN

BROWN

YELLOW

WHITE

PINK

GREY

RED

2

BLUE

2

POWER SUPPLY

OPENING INPUT

SAFETY INPUT

TEST
OUTPUT

WIDTH

RED
LED

1

 Output status when sensor is operational 

2

 For compliance with EN 16005, connection 

 to door controller test output is required.

The door control unit and the door cover profile must be correctly earthed. 

SE

NS

OR

    

H

            

W

2.20 m    2.30 m
2.50 m    2.55 m
3.00 m    2.80 m

    

H

            

W

2.20 m    1.20 m
2.50 m    1.40 m
3.00 m    1.60 m

@ 2.2 m:
Depth of curtain : 8-10 cm
Depth of safety field: 25 cm*

RELAY R1

RELAY R2

12-30 V DC

Check position of IR-curtains with 
Spotfinder and adjust if necessary.

DOOR

Detection field width indicated according to conditions defined in EN 16005 and including dimension of test body CA.

ANGLE

CLOSER

AWAY

ORANGE

* in standard presetting

The size of the detection field varies according to the mounting height of the sensor. 

Summary of Contents for VIO-ST

Page 1: ...x contact voltage 42 V AC DC 0 3 s to 1 s not adjustable Typical 5 ms 12 V 30 V DC 5 10 to be operated from SELV compatible power supplies only 1 6 W 1 8 m to 3 m 1 V Log L 10 V Log H max 30 V 25 C to 55 C IP54 70 dB 20 years EN 62061 SIL2 EN 61496 1 ESPE Type 2 EN 61000 6 2 EN 61000 6 3 EN 12978 EN 50581 EN 16005 EN ISO 13849 1 Pl c CAT 2 under the condition that the door control system monitors ...

Page 2: ...door control unit and the door cover profile must be correctly earthed SENSOR H W 2 20 m 2 30 m 2 50 m 2 55 m 3 00 m 2 80 m H W 2 20 m 1 20 m 2 50 m 1 40 m 3 00 m 1 60 m 2 2 m Depth of curtain 8 10 cm Depth of safety field 25 cm RELAY R1 RELAY R2 12 30 V DC Check position of IR curtains with Spotfinder and adjust if necessary DOOR Detection field width indicated according to conditions defined in ...

Page 3: ...aving the premises The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety and if applicable the machinery directive 2006 42 EC The device cannot be used for purposes other than its intended use All other uses cannot be guaran...

Page 4: ...ED signal The ORANGE LED flashes quickly The sensor signals an internal fault Irregularities in the power supply The sensor receives not enough IR energy The sensor receives too much IR energy The sensor encounters a memory problem The sensor vibrates The sensor sees the door during the assisted setup The sensor sees the door The sensor is disturbed by lamps or another sensor The sensor is disturb...

Reviews: