* When IR:Curtains is set to 0, the AIR will not trigger the output for a period of 5 minutes.
After 5 minutes expires, IR:Curtains will revert back to the previously chosen setting.
DEFAULT
ACTIVE INFRARED SAFETY FIELD
NUMBER OF CURTAINS / POSITION OF CURTAINS
(IR:CURTAINS, MENU 1)
Choose the number of and position of the AIR curtains based on your application.
NOTE: The sensor is defaulted to Non-Threshold setting (3). If threshold is desired, you may
choose Threshold setting 1, 2, 4, or 5; be sure that the curtain placement matches the LCD
screen.
If necessary, use visible spots and red adjustment knob to position properly (see page 11).
UNDERSTANDING THE LCD "CURTAINS" GRAPHICS
GENERAL SETTINGS
the number of squares on a line indicates the curtain number (i.e. C1, C2, or C3)
the rectangles on each side of the setting number represent sliding door panels
THRESHOLD SETTINGS
a dotted line indicates that the given curtain is active at full open, and inactive during door
closing cycle (settings 2 and 5)
a solid line indicates that the given curtain is active at full open and partially active during
door closing cycle (settings 1 and 4)
NON-THRESHOLD SETTINGS
a solid line indicates that the given curtain is always active (settings 3, 6, and 7)