75.5911.02 20180226
Page 1 of 9
COMPONENT ID
PRESENCE SENSOR w/MONITORING
The SuperScan-T detector is a door-mounted presence detection system that is used on automatic pedestrian swing doors. The
SuperScan-T can be used on a monitored or non-monitored system. Unlike other door-mounted sensing devices, the SuperScan-
T's unique electronic architecture allows the detection modules to be mounted near the top of the door, out of harm's way. A rotating
cam is used for the range adjustment of the detection zone. Width patterns may be altered by adding Slave modules to the Master
module. These Slave modules are simply added by inserting them into the aluminum extrusion, then connecting them with the
attached flat ribbon cable to the next module without interrupting other modules in the same extrusion. Once installed, the detection
zone (in addition to being adjustable for distance) can be angled independently from the other modules.
Each SuperScan-T module consists of two optics, a transmitter (TX) and a receiver (RX), and functions independently of the other
modules. The transmitter emits an extremely precise beam, which measures approximately 4" in diameter at a distance of 8'. The
receiver, in turn, receives the infrared beam reflected off of the floor. This transmission and reception forms a detection triangle,
which is the basic premise of detection (called triangulation). Should this angle be interrupted, detection will occur. Detection is
NOT based upon the intensity of the beam, and in principle will not be affected by the color or background of the object that interrupts
the angle.
DESCRIPTION
SPECIFICATION
Power Supply
12 – 24 VAC/VDC ±10%
Current Consumption
Master:
On = 60 mA max.
Off = 30 mA max.
Slave:
On = 40 mA max.
Off = 30 mA max.
Inhibit Input
12 – 24 VAC/VDC ±10% (inhibited when voltage is applied)
Monitoring Request Input
12 – 35 VDC required (polarity-sensitive)
Min. pulse width duration 50 ms
Output Interface; relay
Relay – max. contact rating is 1A @ 30v (resistive)
Detection Range
0 – 8’
Distance Adjustment
2 – 8’ (rotating cam with linear adjustment)
Max. Mounting Height
8’
Detection Time
< 50 ms
Detection Signal Duration
Infinite Presence Detection
Output Hold Time
Potentiometer range: 0.1 – 4.5 seconds
LED Indications
Master:
Red LED = Detection
Green LED = Active Output
Slave:
Red LED = Detection
Operating Temperature Range
-30 – 140 ºF
PCB Dimensions
Master: 10.91” x 1.5”
Slave: 8.75” x 1.5”
Connector to Door Controller
8-position screw terminal on Master PCB
Connection: Master to Slave
Flat-ribbon cable w/connectors and key lock
Max. Number of Slaves
8
Functions Selection
Detection Mode: NO or NC
Normal Mode or Background Analysis Mode
•
Shut off all power going to the header before attempting any wiring procedures.
•
Maintain a clean and safe environment when working in public areas.
•
Constantly be aware of pedestrian traffic around the door area.
•
When performing testing, always stop pedestrian traffic through the doorway that may result in unexpected reactions by the
door.
•
Before powering up, always check placement of all wiring and components to ensure that moving door parts will not catch any
wires and cause damage to equipment.
•
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10, 156.27) upon completion of installation.
SAFETY
PRECAUTIONS
!
CAUTION
DESCRIPTION
TECHNICAL
SPECIFICATIONS
SUPERSCAN-T
USER’S GUIDE
COMPONENT ID