75.5667.10 LZR-I30 20161212
Page 7 of 12
5
-
-
MIN
MAX
20 in
360 in
200 in
20 in
360 in
200 in
75.5667.10 LZR-I30 20161212
Page 7 of 12
FACTORY VALUES
SAFETY FIELD CONFIGURATION (RELAY 2)
3 s
max. 30 s
Wait for the sensor to learn its environment
or lock it by remote control.
Launch a teach-in after changing the sensor position or when new objects are added to or changed in
the detection zone.
During teach-in, the sensor learns and adapts its detection field shape according to its surroundings.
During teach-in, the sensor learns its surroundings and adapts the
detection field shape to these. Objects in the detection field will
be cut out.
WIDTH
HEIGHT
no field
Ex:
for a field width of 62 in
FIELD DIMENSIONS
SAFETY FIELD TEACH-IN
After the teach-in, the field dimensions can be changed by the remote control.
The default field dimension is limited to 200 in x 200 in. You can adapt the dimensions by remote control,
but they can never be bigger than the shape which was defined by the teach-in.