TECHNICAL SPECIFICATIONS

Technology:

laser scanner, time-of-flight measurement

Detection mode:

motion and presence 

Max. detection range:

5.0 m x 6.5 m (16 ft 6 in x 21 ft)

Remission factor:

> 2%

Angular resolution:

0,3516°

Emission characteristics

IR laser:
Red visible laser:

wavelength 905 nm; max. output pulse power 75 W (CLASS 1)
wavelength 650 nm; max. output CW power 3 mW (CLASS 3R)

Supply voltage:

10 – 35 VDC @ sensor side

Power consumption:

< 5 W

Peak current @ power-on:

1.8 A (max. 80 ms @ 35 V)

Cable length:

10 m (30 ft)

Response time

Motion detection:
Presence detection:

typ. 200 ms (adjustable)
typ. 20 ms (max. 80 ms)

Output:

Max. switching voltage:
Max. switching current:
Switching time:
Output resistance:
Voltage drop on output:
Leakage current:

2 electronic relays (galvanic-isolated – polarity-free)
35 VDC / 24 VAC
80 mA (resistive)
t

ON

=5 ms; t

OFF

=5 ms

typ 30 Ω
< 0.7 V @ 20 mA
< 10 µA

Input:

Max. contact voltage:
Voltage threshold:

1 optocoupler (galvanic-isolated – polarity-free)
30 VDC (over-voltage protected)
Log. H: >8 VDC      Log. L: <3 VDC

LED signal:

1 blue LED: power-on status          1 orange LED: error status
2 bi-coloured LEDs: detection/output status (green = no detection, red = detection)

Dimensions:

5.0 in (D) x 3.6 in (W) x 2.75 in (H) (mounting b 0.55 in)

Material:

PC/ASA

Color:

Black

Mounting angles on bracket:

-45°, 0°, 45°

Rotation angles on bracket:

-5 – 5 ° (lockable)

Tilt angles on bracket:

-3 – 3 °

Protection degree:

IP65

Temperature range:

-30 – 60 °C if powered          -10 – 60 °C if unpowered

Humidity:

0 – 95% non-condensing

Vibrations:

< 2G

Pollution on front screen:

max. 30%, homogenous

Norm conformity:

2006/95/EC: LVD
2002/95/EC: RoHS

2004/108/EC: EMC 
EN 60529:2001

IEC 60825-1:2007
EN 60950-1:2005

EN 61000-6-2:2005
EN 61000-6-3:2006

Specifications are subject to change without prior notice.

All values measured in specific conditions.

©BEA

 |

75.5897.02 LZR-H110 20170821

PLEASE KEEP FOR FUR

THER USE – DESIGNED FOR COLOR PRINTING

| Original Instructions

BEA, the sensor manufacturer, cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor/device; 
therefore, BEA does not guarantee any use of the sensor outside of its intended purpose.
BEA strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/
gates, and factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring 
that the sensor system installation is compliant with local, national, and international regulations, codes, and standards. 
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer 
recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices.  Safety inspections must 
be performed during each service call – examples of these safety inspections can be found on an AAADM safety information label (e.g. 
ANSI/DASMA 102, ANSI/DASMA 107, UL 325). 
Verify that all appropriate industry signage and warning labels are in place. 

BEA INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS

Page 12 of 12 

 

75.5897.02 LZR-H110 20170821

Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462 | General Tech Questions: [email protected] | Tech Docs: www.BEAinc.com

BEA hereby declares that the LZR

®

-I100/-I110 is in conformity with the basic requirements and the other relevant provisions of the directives 

2006/95/EC, 2002/95/EC, 2004/108/EC and 2006/42/EC.

Notified Body for EC inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, 45141 D-Essen

EC-type examination certificate number: 44 205 11 392410-002

Angleur, May 2011 

Jean-Pierre Valkenberg, Authorized representative and responsible for technical documentation

The complete declaration of conformity is available on our website:  www.bea-industrial.be

For EC countries: according to the directive 2012/19/EU for Waste Electrical and Electronic Equipment (WEEE)

OBSOLETE

Summary of Contents for LZR-H110

Page 1: ...7 02 LZR H110 20170821 Page 1 of 12 LZR H110 EN LASER SCANNER FOR BARRIERS GATES with max detection range of 5 0 m x 6 5 m 16 5 ft x21 ft User s Guide 75 5897 02 LZR H110 20170821 Page 1 of 12 O B S O L E T E ...

Page 2: ... use aggressive products to clean the front screens Avoid direct exposure to high pressure cleaning Do not look into the laser emitter or the visible red laser beams The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel Only trained and qualified personnel are recommended to install and set up the sensor After installation enter an access code by remote contr...

Page 3: ...lock 2 5 connector 6 protection cover 7 visible laser beam 3 8 notch for tilt angle adjustment 2 9 adjustable bracket 1 Detection LED relay 1 opening field 2 Detection LED relay 2 safety field 3 Error LED 4 Power LED Remote control sequence Possible remote control adjustments Factory values LED flashes slowly All 4 LEDs can be switched off and on again by remote control This can be useful in cases...

Page 4: ...after unlocking you need to enter an access code from 1 to 4 digits X NUMBER OF FLASHES VALUE OF THE PARAMETER field width 4 2 m field width is defined by teach in To end an adjustment session always lock the sensor Enter the existing code ADJUSTING ONE OR MORE PARAMETERS CHECKING A VALUE RESTORING TO FACTORY VALUES SAVING AN ACCESS CODE DELETING AN ACCESS CODE HOW TO USE THE REMOTE CONTROL Page 4...

Page 5: ...connector and position the cable in the slit 40 cm recommended lmin mm hmin mm d mm distance between laser and opening 50 100 150 200 240 360 480 600 52 59 66 73 side view front view POWER SUPPLY POWER SUPPLY RELAY 1 OPENING FIELD RELAY 2 SAFETY FIELD NOT USED RED BLACK WHITE GREEN WHITE BLACK GREEN WHITE BLUE BLUE WHITE ORANGE ORANGE BLACK TEST TEST No test function connect blue and blue white wi...

Page 6: ...After 15 minutes the beams switch off Verify the lateral position of the sensor Make sure the laser beam is visible on the opposite pole Verify if both beams are on equal height WITH REFERENCE POINT surface of min 15 cm The sensor will automatically adjust the safety field on the basis of the reference point if C 00 WITHOUT REFERENCE POINT left right left right Choose the correct mounting side LEF...

Page 7: ...sensor has finished the teach in make sure that the safety field is correctly configured and that the area around the barrier or gate is safe You can increase or decrease the field by 10 cm The safety field can be adapted more precisely by launching a teach in the sensor learns the environment Before launching a teach in make sure that the selected field size is bigger than the desired field size ...

Page 8: ...he walk path and stores this as a new detection field The shortest distance measured by each laser beam is stored by the sensor and determines the field limit You can increase or decrease the field by 10 cm The opening field can be adapted more precisely by launching a teach in the sensor learns the environment Before launching a teach in make sure that the selected field size is bigger than the d...

Page 9: ...TMENTS bidirectional detection approaching and going away BIDIRECTIONAL unidirectional detection only approaching in any direction 400 CENTER unidirectional detection only approaching towards the barrier gate 200 CENTER unidirectional detection only approaching within width of barrier gate 100 CENTER unidirectional detection only approaching towards central zone of barrier gate 50 CENTER unidirect...

Page 10: ... or presence presence presence presence motion presence RELAY 1 RELAY 2 R1R2 MAGIC WAND teach in safety field visible laser beams teach in opening field factory values OUTPUT CONFIGURATION A NO P NC P NC A NO P NC A NO P NC A NO RELAY 1 RELAY 2 R1R2 A active P passive FACTORY VALUES Page 10 of 12 75 5897 02 LZR H110 20170821 O B S O L E T E ...

Page 11: ...lue 3 or 4 Launch a new teach in Sensor is masked Verify and clean the front screens with a damp cloth Orange LED is on Power supply voltage exceeds acceptable limits Check power supply voltage Sensor exceeds temperature limits Verify the temperature of the environment Protect the sensor from sunlight using a cover if necessary Internal error Wait a few seconds If the LED remains ON reset the powe...

Page 12: ...Original Instructions BEA the sensor manufacturer cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor device therefore BEA does not guarantee any use of the sensor outside of its intended purpose BEA strongly recommends that installation and service technicians be AAADM certified for pedestrian doors IDA certified for doors gates and factory trained fo...

Reviews: