TROUBLESHOOTING

No blue LED

No power

Check cable and connexion.

Polarity of power supply is 
inverted

Check the polarity of the power supply.

All LEDs have been deactivated 
by remote control

Activate LEDs using remote control.

Detection LED remains 
green

Detection field too small or 
deactivated

Check size of fields.

Launch a teach-in.

Detection LED remains red

Someone/Something is in the 
detection field

Step out of the field and/or remove the 

any object(s) from the field.

Field is touching floor/wall/
barrier – this leads to detection

Activate the 3 red beams and check if the 

position of the sensor is correct.  If not, 

adjust the hex screws.

Verify the field size.

Launch a teach-in.

Orange LED flashing and 
detection LEDs are red

No background (reference 
point) is found

Check position of sensor.

Check the mounting side setting.  If no 

reference point is found, set the mounting 

side to value 3 or 4.

Launch a new teach-in.

Sensor is masked

Verify and clean the front screens with a 

damp cloth.

Orange LED is on

Power supply voltage exceeds 
acceptable limits

Check power supply voltage.

Sensor exceeds temperature 
limits

Verify the temperature of the environment. 

Protect the sensor from sunlight using a 

cover, if necessary.

Internal error

Wait a few seconds. 

If the LED remains ON, reset the power 

supply. 

If the LED turns on again, replace the 

sensor.

Sensor does not respond 
to the reote control

Remote control batteries not 
installed properly or are dead

Check battery orientation or replace the 

batteries.

Remote control not pointed 
correctly

Point the remote control towards the 

sensor, but with a slight angle. The RC 

should not be pointed in a right angle in 

front of the sensor.

Reflective object is close to the 
sensor

Avoid highly reflective material in proximity 

to the sensor.

Sensor does not unlock

Access code needs entered or 
an incorrect code was used

Cut and restore power supply. 

No code is required to unlock during the 

first minute after powering.

75.5897.02 LZR-H110 20170821   

Page 11 of 12

OBSOLETE

Summary of Contents for LZR-H110

Page 1: ...7 02 LZR H110 20170821 Page 1 of 12 LZR H110 EN LASER SCANNER FOR BARRIERS GATES with max detection range of 5 0 m x 6 5 m 16 5 ft x21 ft User s Guide 75 5897 02 LZR H110 20170821 Page 1 of 12 O B S O L E T E ...

Page 2: ... use aggressive products to clean the front screens Avoid direct exposure to high pressure cleaning Do not look into the laser emitter or the visible red laser beams The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel Only trained and qualified personnel are recommended to install and set up the sensor After installation enter an access code by remote contr...

Page 3: ...lock 2 5 connector 6 protection cover 7 visible laser beam 3 8 notch for tilt angle adjustment 2 9 adjustable bracket 1 Detection LED relay 1 opening field 2 Detection LED relay 2 safety field 3 Error LED 4 Power LED Remote control sequence Possible remote control adjustments Factory values LED flashes slowly All 4 LEDs can be switched off and on again by remote control This can be useful in cases...

Page 4: ...after unlocking you need to enter an access code from 1 to 4 digits X NUMBER OF FLASHES VALUE OF THE PARAMETER field width 4 2 m field width is defined by teach in To end an adjustment session always lock the sensor Enter the existing code ADJUSTING ONE OR MORE PARAMETERS CHECKING A VALUE RESTORING TO FACTORY VALUES SAVING AN ACCESS CODE DELETING AN ACCESS CODE HOW TO USE THE REMOTE CONTROL Page 4...

Page 5: ...connector and position the cable in the slit 40 cm recommended lmin mm hmin mm d mm distance between laser and opening 50 100 150 200 240 360 480 600 52 59 66 73 side view front view POWER SUPPLY POWER SUPPLY RELAY 1 OPENING FIELD RELAY 2 SAFETY FIELD NOT USED RED BLACK WHITE GREEN WHITE BLACK GREEN WHITE BLUE BLUE WHITE ORANGE ORANGE BLACK TEST TEST No test function connect blue and blue white wi...

Page 6: ...After 15 minutes the beams switch off Verify the lateral position of the sensor Make sure the laser beam is visible on the opposite pole Verify if both beams are on equal height WITH REFERENCE POINT surface of min 15 cm The sensor will automatically adjust the safety field on the basis of the reference point if C 00 WITHOUT REFERENCE POINT left right left right Choose the correct mounting side LEF...

Page 7: ...sensor has finished the teach in make sure that the safety field is correctly configured and that the area around the barrier or gate is safe You can increase or decrease the field by 10 cm The safety field can be adapted more precisely by launching a teach in the sensor learns the environment Before launching a teach in make sure that the selected field size is bigger than the desired field size ...

Page 8: ...he walk path and stores this as a new detection field The shortest distance measured by each laser beam is stored by the sensor and determines the field limit You can increase or decrease the field by 10 cm The opening field can be adapted more precisely by launching a teach in the sensor learns the environment Before launching a teach in make sure that the selected field size is bigger than the d...

Page 9: ...TMENTS bidirectional detection approaching and going away BIDIRECTIONAL unidirectional detection only approaching in any direction 400 CENTER unidirectional detection only approaching towards the barrier gate 200 CENTER unidirectional detection only approaching within width of barrier gate 100 CENTER unidirectional detection only approaching towards central zone of barrier gate 50 CENTER unidirect...

Page 10: ... or presence presence presence presence motion presence RELAY 1 RELAY 2 R1R2 MAGIC WAND teach in safety field visible laser beams teach in opening field factory values OUTPUT CONFIGURATION A NO P NC P NC A NO P NC A NO P NC A NO RELAY 1 RELAY 2 R1R2 A active P passive FACTORY VALUES Page 10 of 12 75 5897 02 LZR H110 20170821 O B S O L E T E ...

Page 11: ...lue 3 or 4 Launch a new teach in Sensor is masked Verify and clean the front screens with a damp cloth Orange LED is on Power supply voltage exceeds acceptable limits Check power supply voltage Sensor exceeds temperature limits Verify the temperature of the environment Protect the sensor from sunlight using a cover if necessary Internal error Wait a few seconds If the LED remains ON reset the powe...

Page 12: ...Original Instructions BEA the sensor manufacturer cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor device therefore BEA does not guarantee any use of the sensor outside of its intended purpose BEA strongly recommends that installation and service technicians be AAADM certified for pedestrian doors IDA certified for doors gates and factory trained fo...