2
4
6
8
10
12
16
18
cm*
14
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
0
7
0
0
0.3
0.5
1
1.5
2
3
5
7
9
0.1
sec
sec
FACTORY VALUES
HOLD TIME
Uncovered zone: increase in case of snow, dead leaves, etc.
When DIP 2 is OFF, will change automatically to (10cm).
UNCOVERED
ZONE
In case of false detection, button and are not recommended.
In order to change these settings by remote control, adjust DIP-switch 2 to ON.
*Measured in specific
conditions and dependant on
application and installation.
HOW TO USE THE REMOTE CONTROL
After unlocking, the red LED
flashes and the sensor can
be adjusted with the remote
control.
If the red LED flashes quickly after unlocking, you
need to enter an access code from 1 to 4 digits.
If you do not know the access code,
cut and restore
the power supply
. During 1 minute you can access
the sensor without introducing any access code.
To end an adjustment session,
always lock the sensor.
ADJUSTING ONE OR MORE PARAMETERS
When there are several sensors it is recommended to use a different access code for each sensor in order to avoid
changing settings on all of them at the same time.
LONG PUSH* TIME
VPB OUTPUT
DELAY
VPB1
VPB2
sec
* Long push function: If the push time is longer than 'long push time,' the output will keep
activation until the next push.
The option '0' means disable this long push function.