![BEA IXIO-S CAN User Manual Download Page 4](http://html.mh-extra.com/html/bea/ixio-s-can/ixio-s-can_user-manual_2716060004.webp)
5
4
4
3
SENSOR 1
SENSOR 2
SENSOR 3
SENSOR 4
SENSOR 5
SENSOR 6
SENSOR 7
SENSOR 8
SENSOR 9
SENSOR 10
SENSOR 11
SENSOR 12
SENSOR 13
SENSOR 14
SENSOR 15
SENSOR 16
PRESETTINGS
On the last sensor of the chain, adjust DIP-switch 5 to ON.
the orange LED next to the DIP-switch will be on permanently.
DIP-SWITCH 1-4: CAN-ADDRESS
DIP-SWITCH 5: POSITION IN CHAIN
DOOR CONtROLLER
SENSOR 1
SENSOR 2
SENSOR 3
STANDARD:
standard in- and outdoor installations
factory values for IR immunity & IR number
You can choose one of the following presettings:
CRITICAL ENVIRONMENT:
critical installations due to surroundings or weather
increased IR immunity
SHOPPING STREET:
installations in narrow streets with pedestrian traffic
increased IR immunity & 1 curtain
DIP-switches: each sensor needs a different CAN address depending on its position.
After changing a DIP-switch, the orange LED flashes quickly. Cut and restore power supply to confirm the setting.
address 4
address 0
address 1
address 8
address 9
address 10
address 11
address 12
address 13
address 14
address 15
address 2
address 3
address 5
address 6
address 7