PRESETTINGS

On the last sensor of the chain, adjust DIP-switch 5 to ON. 

the orange LED next to the DIP-switch will be on permanently.

DIP-SWITCH 1-4: CAN-ADDRESS

DIP-SWITCH 5: POSITION IN CHAIN

DOOR CONtROLLER

SENSOR 1

SENSOR 2

SENSOR 3

STANDARD:

 

 

standard in- and outdoor installations

 

 

 

factory values for IR immunity & IR number 

You can choose one of the following presettings:

 CRITICAL ENVIRONMENT:

             critical installations due to surroundings or weather

 

 

 

 increased IR immunity

  SHOPPING STREET:    

  

installations in narrow streets with pedestrian traffic 

 

 

 

 

  increased IR immunity & 1 curtain

DIP-switches: each sensor needs a different CAN address depending on its position.
After changing a DIP-switch, the orange LED flashes quickly. Cut and restore power supply to confirm the setting.

address 4

address 0

address 1

address 8

address 9

address 10

address 11

address 12

address 13

address 14

address 15

address 2

address 3

address 5

address 6

address 7

Summary of Contents for IXIO-S CAN

Page 1: ...witch 7 IR curtain angle adjustment knob SAFETY SENSOR FOR AUTOMATIC SLIDING DOORS User s Guide for product version 0202 and higher See product label for serial number ACCESSORIES BA Bracket accessory CA Ceiling accessory BEA Remote control CDA Curved door accessory according to EN 16005 and DIN 18650 RA Rain accessory ENGLISH ...

Page 2: ...esponsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety the manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor Only trained and qualified personnel may install and setup the sensor the warrant...

Page 3: ...the inside door sensor and the inner curtain of the outside door sensor should always be smaller than 20 cm the distance to the door leaf depends therefore on the thickness of the door leaf the size of the detection field varies according to the mounting height and the settings of the sensor the full door width must be covered Mounting height Detection width 2 00 m 2 20 m 2 50 m 3 00 m 3 50 m 2 00...

Page 4: ...ory values for IR immunity IR number You can choose one of the following presettings CRITICAL ENVIRONMENT critical installations due to surroundings or weather increased IR immunity SHOPPING STREET installations in narrow streets with pedestrian traffic increased IR immunity 1 curtain DIP switches each sensor needs a different CAN address depending on its position After changing a DIP switch the o...

Page 5: ...mplete reset to factory values FACTORY RESET Always additionally adjust the arrow position on the sensor with a screwdriver 2 8 m 6 7 EN 16005 2 2 m 6 7 BS 7036 Sensors mounted close to each other need a different frequency service mode no IR detection during 15 minutes maintenance this value excludes conformity of the door system to EN 16005 and DIN 18650 min value for DIN18650 1 min min value fo...

Page 6: ... and adjust the IR angle Replace sensor ORANGE LED flashes 5 x the sensor receives too much IR energy ORANGE LED flashes 8 x IR power emitter is faulty Replace sensor the remote control does not react Enter the right password If you forgot the code cut and restore the power supply to access the sensor without entering a password during 1 minute the sensor is protected by a password the sensor is d...

Page 7: ...ain Number of curtains 2 CAN EN 12978 EN ISO 13849 1PL c CAt 2 under the condition that the door control system monitors the sensor at least once per door cycle IEC 61496 1 ESPE type 2 EN 16005 Chapter 4 6 8 DIN 18650 1 Chapter 5 7 4 BS 7036 1 Chapter 8 1 Detection mode technology Communication interface Norm conformity Specifications are subject to changes without prior notice All values measured...

Page 8: ...iginal instructions 47 0190 V4 06 19 BEA hereby declares that the IXIO S CAN is in conformity with the basic requirements and the other relevant provisions of the directives 2014 30 EU 2006 42 EC and 2011 65 EU This product should be disposed of separately from unsorted municipal waste PLEASE KEEP FOR FURTHER USE DESIGNED FOR COLOUR PRINTING ...

Reviews: