BEA IXIO-S CAN User Manual Download Page 2

2

x

INSTALLATION

the sensor should be 

fixed firmly to avoid 

extreme vibrations.

Do not cover the sensor.

Avoid moving objects 

and light sources in 

the detection field.

Avoid highly 

reflective objects in 

the infrared field.

It is recommended to clean 

the optical parts at least once 

a year or more if required due 

to environmental conditions.

Do not use aggressive 

products to clean 

the optical parts.

• 

the device cannot be used for purposes other than its intended use. All other uses cannot be guaranteed 

by the manufacturer of the sensor.  

• 

the manufacturer of the door system is responsible for carrying out a risk assessment and installing the 

sensor and the door system in compliance with applicable national and international regulations and 

standards on door safety. 

• 

the manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate 

adjustments of the sensor.

Only trained and 

qualified personnel 

may install and setup 

the sensor. 

the warranty is invalid if 

unauthorized repairs are 

made or attempted by 

unauthorized personnel. 

Always test the good 

functioning of the 

installation before 

leaving the premises.

the door control unit 

and the door cover 

profile must be correctly 

earthed. 

MAINTENANCE

SAFETY

LED-SIGNAL

Presence 
detection

LED flashes

LED flashes 
quickly

LED is off

LED flashes 
x times

LED flashes 
red-green

Summary of Contents for IXIO-S CAN

Page 1: ...witch 7 IR curtain angle adjustment knob SAFETY SENSOR FOR AUTOMATIC SLIDING DOORS User s Guide for product version 0202 and higher See product label for serial number ACCESSORIES BA Bracket accessory CA Ceiling accessory BEA Remote control CDA Curved door accessory according to EN 16005 and DIN 18650 RA Rain accessory ENGLISH ...

Page 2: ...esponsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety the manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor Only trained and qualified personnel may install and setup the sensor the warrant...

Page 3: ...the inside door sensor and the inner curtain of the outside door sensor should always be smaller than 20 cm the distance to the door leaf depends therefore on the thickness of the door leaf the size of the detection field varies according to the mounting height and the settings of the sensor the full door width must be covered Mounting height Detection width 2 00 m 2 20 m 2 50 m 3 00 m 3 50 m 2 00...

Page 4: ...ory values for IR immunity IR number You can choose one of the following presettings CRITICAL ENVIRONMENT critical installations due to surroundings or weather increased IR immunity SHOPPING STREET installations in narrow streets with pedestrian traffic increased IR immunity 1 curtain DIP switches each sensor needs a different CAN address depending on its position After changing a DIP switch the o...

Page 5: ...mplete reset to factory values FACTORY RESET Always additionally adjust the arrow position on the sensor with a screwdriver 2 8 m 6 7 EN 16005 2 2 m 6 7 BS 7036 Sensors mounted close to each other need a different frequency service mode no IR detection during 15 minutes maintenance this value excludes conformity of the door system to EN 16005 and DIN 18650 min value for DIN18650 1 min min value fo...

Page 6: ... and adjust the IR angle Replace sensor ORANGE LED flashes 5 x the sensor receives too much IR energy ORANGE LED flashes 8 x IR power emitter is faulty Replace sensor the remote control does not react Enter the right password If you forgot the code cut and restore the power supply to access the sensor without entering a password during 1 minute the sensor is protected by a password the sensor is d...

Page 7: ...ain Number of curtains 2 CAN EN 12978 EN ISO 13849 1PL c CAt 2 under the condition that the door control system monitors the sensor at least once per door cycle IEC 61496 1 ESPE type 2 EN 16005 Chapter 4 6 8 DIN 18650 1 Chapter 5 7 4 BS 7036 1 Chapter 8 1 Detection mode technology Communication interface Norm conformity Specifications are subject to changes without prior notice All values measured...

Page 8: ...iginal instructions 47 0190 V4 06 19 BEA hereby declares that the IXIO S CAN is in conformity with the basic requirements and the other relevant provisions of the directives 2014 30 EU 2006 42 EC and 2011 65 EU This product should be disposed of separately from unsorted municipal waste PLEASE KEEP FOR FURTHER USE DESIGNED FOR COLOUR PRINTING ...

Reviews: