![BEA IXIO-S CAN User Manual Download Page 3](http://html.mh-extra.com/html/bea/ixio-s-can/ixio-s-can_user-manual_2716060003.webp)
1
max. 5 cm
3
2
DIN 18650
BS 7036
EN 16005
3,50 m
3 m
2,50 m
2 m
d max = 2,5 m
3,50 m
3 m
2,50 m
2 m
max.
9 cm**
2x
W W
W
N
N
W
N N
+
-
d max = 3 m
WIDtH
tIP!
Additional
adjustments
are possible
(see p. 5)
Part of the detection field can be masked to reduce it.
the arrow position determines the width of the detection field.
INFRARED SAFETY FIELD
If necessary, adjust the IR-curtain
angle (from -7° to 4°, default 0°).
Activate the visible* spots to verify
the position of the IR-curtain.
ANGLE
* Visibility depends on external conditions. When spots are not visible, use the Spotfinder to locate the curtains.
** the distance between the inner curtain of the inside door sensor and the inner curtain of the outside door sensor should
always be smaller than 20 cm. the distance to the door leaf depends therefore on the thickness of the door leaf.
the size of the detection field varies according to the
mounting height and the settings of the sensor.
the full door width must be covered.
Mounting
height
Detection
width
2.00 m
2.20 m
2.50 m
3.00 m
3.50 m
2.00 m
2.20 m
2.50 m
d max
d max
Always verify the actual detection field width
with a piece of paper and not the Spotfinder,
which detects the whole emitted field.
3.50 m
3 m
2.50 m
2 m
d max = 2.5 m
3.50 m
3 m
2.50 m
2 m
MOUNTING & WIRING
ENGLISH
IXIO-S CAN: INSTALLATION GUIDE
Plug the connector with the WHITE and
GREEN wires on top towards the sensor cover.
DOOR
GREEN
BROWN
POWER
SUPPLY
CAN HIGH
CAN LOW
YELLOW
WHITE
CLOSER
AWAY