FALCON (Mounting height: 16.5’ (5m) 

 

 

 

FALCON (Mounting height: 11.5’ (3.5 m) 

 

 

 

FALCON XL (Mounting height: 8’ (2.5 m)

 

 

 

 

 
 
 
 
 

 

When the power is turned ON the red and green LED flash for a few seconds. 

 

During a detection the red LED lights on. 

 

During configuration the red LED flashes a number of times corresponding to the parameter being changed (see table). The green 
LED flashes a number of times corresponding to its setting. 

 

 
SENSING FIELD 
DIMENSIONS 

The sensing fields here on 
the left correspond to the 
following adjustments: 
 

 

Tilt angle: 
15°, 30°, 45° 

 

Sensitivity: 9 

The sensing fields 
here on the left 
correspond to the 
following adjustments: 
 

 

Tilt angle: 30° 

 

Sensitivity: 
9,6,3 

The sensing fields here on 
the left correspond to the 
following adjustments: 
 

 

Tilt angle: 
15°, 30°, 45° 

 

Sensitivity: 9 

The sensing fields here on 
the left correspond to the 
following adjustments: 
 

 

Tilt angle: 
15°, 30°, 45° 

 

Sensitivity: 9 

The sensing fields 
here on the left 
correspond to the 
following adjustments: 
 

 

Tilt angle: 30° 

 

Sensitivity: 
9,6,3 

The sensing fields 
here on the left 
correspond to the 
following adjustments: 
 

 

Tilt angle: 30° 

 

Sensitivity: 
9,6,3 

 
LED SIGNAL 

 

6          3           0          3          6

3   

    

12 

15 

18 

21 

3   

    

12

15

18

21

H = 16.5 ft. 
S = 9

 

 

6          3           0          3          6 

3   

    

12

15

18

21

3   

    

12 

15 

18 

21 

H = 16.5 ft. 
Angle = 30

°

 

  

6          3           0          3          6

3   
 
 

 
     

 
 
12 
 
 
15 
 
 
18 

 

 
21 

3   

    

12

15

18

21

H = 11.5 ft. 
S = 9

 

  

6          3           0          3          6 

H = 11.5 ft. 
Angle = 30

°

 


 

    


 
 

 
 
12
 
 
15


 
     

 
 

 
 
12 
 
 
15 

 

 

6          3           0          3          6

H = 8 ft. 
S = 9 

 


 
     

 
 

 
 
12 
 
 
15 


 

    


 
 

 
 
12
 
 
15

  

6          3           0          3          6 

H = 8 ft. 
Angle = 30

°

 


 

    


 
 

 
 
12
 
 
15


 
     

 
 

 
 
12 
 
 
15 

Summary of Contents for FALCON DR

Page 1: ...witching power 30W DC 60VA AC Hold time 0 5s to 9s adjustable Temperature range 22 F to 122 F 30 C to 60 C Degree of protection IP65 Norm conformity R TTE 1999 5 EC EMC 89 336 EEC Dimensions 4 W x 5 D x 3 H 102 mm W x 127 mm D x 96 mm H Weight 0 88 lbs 0 4 kg Material of housing ABS and polycarbonate Material of bracket Anodized aluminium Length of cable 33 10m Manual adjustment Orientation of sen...

Page 2: ...ousing Screw the 2 front cover screws and tighten the retaining nut Check that both locking collars are at the same position Align the bracket slot to the locking collar guide as shown BROWN GREEN Power supply YELLOW COM 1 WHITE NC 1 PINK NO 1 BLACK COM 2 RED NC 2 BLUE NO 2 To insert or to remove the cable Unscrew the retaining nut Pass the cable through the retaining nut and the grommet Screw the...

Page 3: ...ng adjustments Tilt angle 30 Sensitivity 9 6 3 The sensing fields here on the left correspond to the following adjustments Tilt angle 15 30 45 Sensitivity 9 The sensing fields here on the left correspond to the following adjustments Tilt angle 15 30 45 Sensitivity 9 The sensing fields here on the left correspond to the following adjustments Tilt angle 30 Sensitivity 9 6 3 The sensing fields here o...

Page 4: ...NLOCK key 4 Enter your 4 digit access code using 0 9 NUMBER keys 1 During the first sensor adjustment or if the access code is reset to the 0000 value factory setting or during the first minute after the power on press only the UNLOCK key 4 no access code required UNLOCK with access code UNLOCK without access code The red LED flashes quickly waiting for the access code After entering the correct a...

Page 5: ...nterferences with the sensor DETECTION MODE Press the DETECTION MODE key 8 Use the NUMBER keys 1 3 1 to select the required mode Key 1 bidirectional mode Key 2 unidirectional mode Key 3 unidirectional mode with the MTF function DETECTION MODE With the bidirectional mode the approaching and departing target is detected With the unidirectional mode only the approaching target is detected Using the M...

Page 6: ...o the factory values Press and hold both push buttons simultaneously until the two LEDs switch on for 1 second after 2 seconds During the manual adjustment session the red and green LEDs flash successively and continuously The flashing number of the red LED provides the number of the displayed parameter see next table The flashing number of the green LED provides the value of the displayed paramet...

Page 7: ... on unlock then on lock and introduce a new access code Batteries in the remote control are weak or installed improperly Check the batteries insertion Change the batteries The sensor does not respond to the remote control Remote control is badly pointed Point the remote control towards to the sensor TROUBLE SHOOTING Do not leave problems unresolved If a satisfactory solution cannot be achieved aft...

Reviews: