BEA EAGLE ONE HM User Manual Download Page 4

4/8 

1.  INSERTION OF BATTERIES 

 

 

 

 Open the battery compartment at the back of the remote control; 

 Insert two AAA batteries supplied with the remote control as shown on the left; 

 Close the battery compartment.

 

 

 

0-9 Number keys   (1)

Not used   (2)

Plus   (3)

Unlock   (4)

Minus   (5)

Holdtime   (6)

Sensitivity   (7)

Detection mode   (8)

Immunity   (9)

 

 

 

 

(10)  Not used 
(11)  Not used 

(12)  Not used  

(13)  Mounting height 
(14)  Door control 
(15)  Check Values  
(16)  Lock  

(17)  Output configuration  

(18)  Not used  

(19)  Setup  

(20)  Not used 

 

 

Note: 

For optimum results point the remote control to the sensor 

before pressing its buttons. The sensor can be adjusted with or 
without its cover from a distance up to 5m. 

 

 

2.  CONFIGURATION OF THE SENSOR 

 

Every adjustment session using the infrared remote control must start with unlocking and end with a double locking. 

 

 

 
The table below lists the parameters able to be adjusted by remote control and the operations required in order to adjust these 
parameters.

 

 

 

 

PARAMETERS 

OPERATIONS 

LED SIGNAL 

UNLOCK 

 

 

Press the

 UNLOCK

 key (4).  

Enter your access code using 

0-9

 

NUMBER

 keys (1). The access code can be composed 

of 1 to 4 digits (factory values or no access code: 0 or 0000). 

During  the first sensor adjustment or if the access code is reset to the 

"0000" value 

(factory setting)

 or during the first minute after the power-on, press only the 

UNLOCK

 key 

(4) (no access code required). 
 

UNLOCK with access code of 4 digits 

 

 

 

 

 

UNLOCK with access code of less than 4 digits 

 

 

 

UNLOCK without access code 

 

 

The red LED flashes quickly waiting for the 
access code. 
 
After entering the correct access code or if no 
access code is required, the red LED flashes 
slowly to indicate that the unlock was successful 
and the adjustment session has begun. 

 

Note.: 

 = Adjustment session ON 

LOCK 

 

 

When all the parameters have been set, press the

 LOCK

 key (16). 

If you wish to enter a new access code, use

 0-9

 

NUMBER 

keys (1) to enter the new 4-digit 

access code within 1 minute.

 

If no access code is entered or if you want to keep the current access code, press the 

LOCK

 key (16) once more.  

If no remote control key is pressed within 1 minute, the adjustment session is automatically 
locked. 
 

LOCK with access code change 

 

 

 

 

 

 

LOCK without access code or access code change 

 

 

 

 

The red LED stops flashing and returns to its 
normal function. 

 

 
FUNCTIONS 
CONFIGURATION 
WITH REMOTE 
CONTROL 

Summary of Contents for EAGLE ONE HM

Page 1: ... 215 kg Material ABS Color of housing anthracite gray aluminum finish or white Length of cable 2 5m Manual adjustment Sensitivity by push buttons Orientation of sensing field mechanically Remote control adjustments Sensitivity Hold time Detection mode Immunity Mounting height Output configuration Door control Security 10 levels from 0 5s to 9s in 10 levels uni bidirectional MTF reverse mode Eagle ...

Page 2: ...ock 12 24V AC DC COM NO NC This device may be fixed on the ceiling as long as the spherical part of the sensor is facing in the direction opposite the door and as long as an angular position of around 70 is chosen for the antenna For the mounting on the upper part of the door operator profile use the EBA support For a mounting into the ceiling use the ECA embedding support For a better water tight...

Page 3: ...GLE OF THE ANTENNA The sensing fields here on the right correspond to the following adjustments Sensitivity 9 Bidirectional mode Mounting height 5m To obtain a sensing field as close to the door as possible set the antenna at its minimum tilt angle 0 to 15 Example of deep field operator application To obtain a sensing field close to the door set the antenna at a tilt angle of 30 Example of standar...

Page 4: ...e access code can be composed of 1 to 4 digits factory values or no access code 0 or 0000 During the first sensor adjustment or if the access code is reset to the 0000 value factory setting or during the first minute after the power on press only the UNLOCK key 4 no access code required UNLOCK with access code of 4 digits UNLOCK with access code of less than 4 digits UNLOCK without access code The...

Page 5: ... MODE key 8 Use the NUMBER keys 1 5 1 to select the required mode Key 1 Bidirectional mode Key 2 Unidirectional mode Key 3 Unidirectional mode with MTF function Key 4 Unidirectional mode reverse Key 5 Unidirectional mode reverse with MTF function DETECTION MODE With the bidirectional mode the approaching and departing target is detected With the unidirectional mode only the approaching target is d...

Page 6: ...or control is set to level 3 Check the wiring and the power supply Set door control to automatic mode level 1 The sensor sees the door moving Increase the tilt angle and or reduce the sensitivity and or increase the immunity The door opens and closes constantly When closing the door creates vibrations picked up by the sensor Ensure that the sensor is correctly fixed Switch to unidirectional mode I...

Page 7: ...ck during the first minute after powering Press on unlock then on lock and introduce a new access code Batteries in the remote control are weak or installed improperly Check the batteries insertion Change the batteries The sensor does not respond to the remote control Remote control badly pointed Point the remote control towards the sensor TROUBLE SHOOTING ...

Page 8: ...ion of conformity and other technical documentation are available on our website or can be requested by phone or mail BEA S A LIEGE Science Park Allée des Noisetiers 5 B 4031 Angleur Tel 3243616565 Fax 3243612858 info bea be www bea be ...

Reviews: