BEA EAGLE ONE HM User Manual Download Page 3

3/8 

 

A.  DIMENSIONS  OF  THE  SENSING  FIELD  (WIDTH,  DEPTH,  DEAD  ZONE)  ARE  DETERMINED  BY  THE 

SENSITIVITY SETTING (0 to 9) 

 

 

 
 
 
 
 
The sensing fields here on the right correspond to 
the following adjustments: 

 

Vertical angle of antenna: 20; 

 

Bidirectional mode; 

 

Mounting height: 5m

 

 

 

B.  POSITION OF THE SENSING FIELD IS DETERMINED BY THE LATERAL ANGLE OF THE PLANAR ANTENNA 

 

 

 
The sensing fields here on the 
right correspond to the following 
adjustments:   

 

Bidirectional mode; 

 

Lateral angle of the antenna:  
30°, -  30°; 

 

Mounting height 5m.

 

 

 

C.  POSITION OF THE SENSING FIELD IS DETERMINED BY THE VERTICAL ANGLE OF THE ANTENNA 
 

 

The  sensing  fields  here  on  the  right 
correspond to the following adjustments:       

 Sensitivity: 9; 

 Bidirectional mode; 

 Mounting height: 5m.

 

 

 

 

To obtain a sensing field as 
close to the door as possible, 
set the antenna at its 
minimum tilt angle (0° to 15°). 

 

Example of  
deep-field operator 
application. 

 

 

 

 

 

To obtain a sensing field close 
to the door, set the antenna at a 
tilt angle of 30°. 

 

Example of standard 
operator application. 

 

 

 

 

 

To obtain a sensing field 
distant from the door, set the 
antenna at a tilt angle of 45°. 

 

Example of standard 
operator application  
(with dead zone). 

 

FOR A CEILING MOUNTING: 

 
 

The sensing fields  here on the right 
correspond to the following adjustments: 

 

Sensitivity: 9; 

 

Bidirectional mode; 

 

Mounting height: 5m.

 

 

 

 
MECHANICAL 
CONFIGURATION 

m

 

m

 

m

 

m

 

m

 

m

 

m

 

m

 

Summary of Contents for EAGLE ONE HM

Page 1: ... 215 kg Material ABS Color of housing anthracite gray aluminum finish or white Length of cable 2 5m Manual adjustment Sensitivity by push buttons Orientation of sensing field mechanically Remote control adjustments Sensitivity Hold time Detection mode Immunity Mounting height Output configuration Door control Security 10 levels from 0 5s to 9s in 10 levels uni bidirectional MTF reverse mode Eagle ...

Page 2: ...ock 12 24V AC DC COM NO NC This device may be fixed on the ceiling as long as the spherical part of the sensor is facing in the direction opposite the door and as long as an angular position of around 70 is chosen for the antenna For the mounting on the upper part of the door operator profile use the EBA support For a mounting into the ceiling use the ECA embedding support For a better water tight...

Page 3: ...GLE OF THE ANTENNA The sensing fields here on the right correspond to the following adjustments Sensitivity 9 Bidirectional mode Mounting height 5m To obtain a sensing field as close to the door as possible set the antenna at its minimum tilt angle 0 to 15 Example of deep field operator application To obtain a sensing field close to the door set the antenna at a tilt angle of 30 Example of standar...

Page 4: ...e access code can be composed of 1 to 4 digits factory values or no access code 0 or 0000 During the first sensor adjustment or if the access code is reset to the 0000 value factory setting or during the first minute after the power on press only the UNLOCK key 4 no access code required UNLOCK with access code of 4 digits UNLOCK with access code of less than 4 digits UNLOCK without access code The...

Page 5: ... MODE key 8 Use the NUMBER keys 1 5 1 to select the required mode Key 1 Bidirectional mode Key 2 Unidirectional mode Key 3 Unidirectional mode with MTF function Key 4 Unidirectional mode reverse Key 5 Unidirectional mode reverse with MTF function DETECTION MODE With the bidirectional mode the approaching and departing target is detected With the unidirectional mode only the approaching target is d...

Page 6: ...or control is set to level 3 Check the wiring and the power supply Set door control to automatic mode level 1 The sensor sees the door moving Increase the tilt angle and or reduce the sensitivity and or increase the immunity The door opens and closes constantly When closing the door creates vibrations picked up by the sensor Ensure that the sensor is correctly fixed Switch to unidirectional mode I...

Page 7: ...ck during the first minute after powering Press on unlock then on lock and introduce a new access code Batteries in the remote control are weak or installed improperly Check the batteries insertion Change the batteries The sensor does not respond to the remote control Remote control badly pointed Point the remote control towards the sensor TROUBLE SHOOTING ...

Page 8: ...ion of conformity and other technical documentation are available on our website or can be requested by phone or mail BEA S A LIEGE Science Park Allée des Noisetiers 5 B 4031 Angleur Tel 3243616565 Fax 3243612858 info bea be www bea be ...