background image

EAGLE 5 & 6

1

3

5

4

2

Specifications are subject to changes without prior notice.
Measured in specific conditions

TECHNICAL SPECIFICATIONS

DESCRIPTION

ENGLISH

Opening sensors for automatic doors

1. main 

connector

2. potentiometer
3. radar 

antenna

4. DIP-switch
5. cover

Technology:
Transmitter frequency:  
Transmitter radiated power:
Transmitter power density:
Detection mode:
Min. detection speed:
Supply voltage:
Mains frequency:
Max power consumption:
Output: 
   Max. contact voltage:
   Max. contact current:
   Max. switching power:
Mounting height: 
Degree of protection:
Temperature range:
Dimensions:
Tilt angles:
Material:
Weight:
Cable lenght:
Norm conformity:

microwave doppler radar
24.150 GHz
< 20 dBm EIRP
< 5 mW/cm²
motion
5 cm/s (measured in sensor axis)
12 V to 24 V AC ±10%; 12 V to 24 V DC +30% / -10%
50 to 60 Hz
< 2 W
relay (free of potential change-over contact)
42 V AC/DC
1 A (resistive)
30 W (DC) / 60 VA (AC)
from 1.8 m to 3 m 
IP54
from -20 °C to + 55 °C
120 mm (L) x 80 mm (H) x 50 mm (W)
0° to 90° vertical; -30° to +30° lateral
ABS
120 g
2.5 m
R&TTE 1999/5/EC; EMC 2004/108/EC

EAGLE 5: energy-saving unidirectional sensor 
EAGLE 6: bidirectional sensor 

Other use of the device is outside the permitted purpose and can not be 
guaranteed by the manufacturer.
The manufacturer cannot be held responsible for incorrect installations or 
inappropriate adjustments of the sensor.

Please keep for further use
Designed for colour printing

BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | [email protected] | WWW.BEA.BE

1

1
2

3

4

5

1
2

3

1

2

1

3

1

2

TROUBLESHOOTING

The door remains 
closed. 
The LED is OFF.

The sensor power is off.

Check the wiring and the power supply.

The door does not 
react as expected.

The door opens 
and closes 
constantly.

Improper output 
configuration on the sensor.

The sensor is disturbed 
by the door motion or 
vibrations caused by the 
door motion.

The door opens for 
no apparent reason.

It rains and the sensor 
detects the motion of the 
rain drops.

Change the output configuration setting on 
each sensor connected to the door operator.

Make sure the sensor is fixed properly.
Make sure the detection mode is unidirectional.
Increase the antenna angle.
Increase the immunity filter.
Reduce the field size.

Change the antenna angle.
Decrease the field size.
Increase the immunity filter.

Make sure the detection mode is unidirectional.
Increase the immunity filter.
Install the ORA (rain accessory).

In highly reflective 
environments, the sensor 
detects objects outside of its 
detection field.

In airlock vestibules, 
the sensor detects the 
movement of 
the opposite door.

Change the antenna angle.
Increase the immunity filter.

©

B

E

A  

X

X

.XXXX

 /

 V

1

 - 

08

.1

1

Reviews: