TECHNICAL SPECIFICATIONS
DESCRIPTION
ENGLISH
Opening sensors for automatic doors
1. main
connector
2. potentiometer
3. radar
antenna
4. DIP-switch
5. cover
Technology:
Transmitter frequency:
Transmitter radiated power:
Transmitter power density:
Detection mode:
Min. detection speed:
Supply voltage:
Mains frequency:
Max power consumption:
Output:
Max. contact voltage:
Max. contact current:
Max. switching power:
Mounting height:
Degree of protection:
Temperature range:
Dimensions:
Tilt angles:
Material:
Weight:
Cable lenght:
Norm conformity:
microwave doppler radar
24.150 GHz
< 20 dBm EIRP
< 5 mW/cm²
motion
5 cm/s (measured in sensor axis)
12 V to 24 V AC ±10%; 12 V to 24 V DC +30% / -10%
50 to 60 Hz
< 2 W
relay (free of potential change-over contact)
42 V AC/DC
1 A (resistive)
30 W (DC) / 60 VA (AC)
from 1.8 m to 3 m
IP54
from -20 °C to + 55 °C
120 mm (L) x 80 mm (H) x 50 mm (W)
0° to 90° vertical; -30° to +30° lateral
ABS
120 g
2.5 m
R&TTE 1999/5/EC; EMC 2004/108/EC
EAGLE 5: energy-saving unidirectional sensor
EAGLE 6: bidirectional sensor
Other use of the device is outside the permitted purpose and can not be
guaranteed by the manufacturer.
The manufacturer cannot be held responsible for incorrect installations or
inappropriate adjustments of the sensor.
Please keep for further use
Designed for colour printing
BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | [email protected] | WWW.BEA.BE
1
1
2
3
4
5
1
2
3
1
2
1
3
1
2
TROUBLESHOOTING
The door remains
closed.
The LED is OFF.
The sensor power is off.
Check the wiring and the power supply.
The door does not
react as expected.
The door opens
and closes
constantly.
Improper output
configuration on the sensor.
The sensor is disturbed
by the door motion or
vibrations caused by the
door motion.
The door opens for
no apparent reason.
It rains and the sensor
detects the motion of the
rain drops.
Change the output configuration setting on
each sensor connected to the door operator.
Make sure the sensor is fixed properly.
Make sure the detection mode is unidirectional.
Increase the antenna angle.
Increase the immunity filter.
Reduce the field size.
Change the antenna angle.
Decrease the field size.
Increase the immunity filter.
Make sure the detection mode is unidirectional.
Increase the immunity filter.
Install the ORA (rain accessory).
In highly reflective
environments, the sensor
detects objects outside of its
detection field.
In airlock vestibules,
the sensor detects the
movement of
the opposite door.
Change the antenna angle.