1
1
0
0
1
1
1
1
2
2
3
3
m
m
m
m
START
STOP
+
-
3/8
By turning the screw
clockwise,
the detection depth
decreases
resp.
The detection field approaches the sensor
.
By turning the screw
counter clockwise
, the detection depth
increases.
The angle of the radar field can be adapted by turning the adjustment screw.
Installation height: 3.2m
Field size: 8
Rejection mode: 1 (detection of pedestrians)
Installation height: 2.5m
Field size: 7
Rejection mode: 1 (detection of pedestrians)
The IR-detection field is approx.15% smaller than the zone detected by the Spotfinder.
If rejection mode 2 (detection of pallets) is selected, the radar detection field is slightly smaller.
12-24V
GND
COM
NO
COM
NO
NC
NC
GREEN
BROWN
WHITE
YELLOW
PINK
VIOLET
GREY
BLACK
POWER-
SUPPLY
START-
SIGNAL
STOP-
SIGNAL
NOT USED
NOT USED
DETECTION FIELD
WIRING
The Spotfinder is necessary to position the
detection field correctly.
The CONDOR ID should be positioned by using
the Spotfinder so that the START-line is at the
desired distance from the sensor.
Therefore the Spotfinder should be put on the
floor and turned towards the sensor. The
CONDOR ID should be adjusted until the
Spotfinder detects the first line of IR-spots.
If the adjustment screw has to be repositioned to the default position as shown above, it is mandatory to
start from the 12 o’clock position and turn counterclockwise to the 9 o’clock position.