9   Company Contact

8   User Operation

7   Additional Procedures

 

red

 

red

 

red flashing

 

red flashing

 

red flashing

 

red flashing

 

red flashing

 

red flashing

DOOR    MODE

green

green

green

green

OPTIONAL:  Door bell and tamper alarm
4a) Door bell:

a. Connect an external speaker (8Ω, 0.5w) to brown/white and black/white wires of this device.

b. Press the star (*) key and the external speaker rings as a door bell.

4b) External tamper alarm:

This feature allows a built-in buzzer to activate if the keypad is removed from the wall.  The alarm will stop 

automatically in 60 seconds or if the admin code is entered before the 60-second timeout.
FACTORY DEFAULT:  OFF

a. To turn on the tamper alarm feature, enter “setup” mode.

b. Press the star (*) key and then “6”.  Mode LED will flash red.

c. Press “0” and then “2”.  A long beep will sound.  Mode LED will turn red.

d. Press “#” again to exit “setup” mode.  Mode LED turns green.

a. To turn off the tamper alarm, enter “setup” mode.

b. Press the star (*) key and then “6”.  Mode LED will flash red.

c. Press “0” and then “1”.  A long beep will sound.  Mode LED will turn red.

d. Press “#” again to exit “setup” mode.  Mode LED turns green.

OPTIONAL:  Remove all user codes

a. Enter “setup” mode.

b. Press the star (*) key and then “8”.  Mode LED will flash red.

c. Press “8” twice.  A long beep will sound.  Mode LED will flash red.

d. Press “#” again to exit “setup” mode.  Mode LED turns green

OPTIONAL:  Restore to factory defaults

a. Enter “setup” mode.

b. Press the star (*) key and then “8”.  Mode LED will flash red.

c. Press “9” twice.  A long beep will sound.  Mode LED will flash red.

d. Press “#” again to exit “setup” mode.  Mode LED turns green

Simply enter the user code provided to you.
If 3 invalid consecutive keyboard input entries occur, the keypad will be disabled for 60 seconds. 

Summary of Contents for 10KEYPADU

Page 1: ...nds Output 2 relays free of potential change over contact Max contact voltage 42 VAC VDC Max contact current 1 A resistive Max switching power 30 W VDC 48 VA VAC Cable length 3 ft Operating temperature 22 158 F Operating humidity 0 95 non condensing IP rating IP66 waterproof and dustproof Dimension 10KEYPADU 3 0 W x 4 7 H x 0 9 D 76 mm x 120 mm x 22 mm 10KEYPADUSL 1 7 W x 5 9 H x 0 95 D 44 mm x 15...

Page 2: ...on Wiring CAUTION Do not damage the tamper sensor 4 Installation Notes Handle the equipment with care Add threadlocker to all screws before installing Firmly tighten screws 1 Using the supplied hex key remove the backcase screw from the keypad bottom 2 Use the drilling template and drill required holes For surface mounting drill the 4 holes marked as B in the installation image below for single ga...

Page 3: ...onsiting of the correct amount of digits e g if the admin code length is changed to 6 digits the admin code defaults to 123456 a Enter setup mode b Press the star key and then 9 Mode LED will flash red c Press 0 and then 4 A short beep will sound Mode LED will turn red d Enter the length of the admin code in digits ranging from 2 to 6 2 is the minimum code length and 6 is the maximum one beep admi...

Page 4: ...LED will turn red d Enter a 3 digit number 000 999 to set the electronic location for the zone 1 user code LED remains red and a a short beep will sound after entering the 3 digit number e Enter the new user code The user code must be the same length as the admin code A long beep will sound User code is successfully added The new code will replace the existing code stored in the same location f Re...

Page 5: ...o turn on the tamper alarm feature enter setup mode b Press the star key and then 6 Mode LED will flash red c Press 0 and then 2 A long beep will sound Mode LED will turn red d Press again to exit setup mode Mode LED turns green a To turn off the tamper alarm enter setup mode b Press the star key and then 6 Mode LED will flash red c Press 0 and then 1 A long beep will sound Mode LED will turn red ...

Page 6: ...urs Durée du double verrouillage 0 99 secondes Sortie 2 relais contact sans potentiel Tension de contact max 42 VCA VCC Courant de contact max 1 A résistant Puissance de commutation max 30 W VCC 48 VA VCA Longueur du câble 3 pi Température de fonctionnement 22 158 F Humidité en fonctionnement 0 95 sans condensation Indice de protection IP66 résistance à l eau et à la poussière Dimension 10KEYPADU ...

Page 7: ...ez de l enduit frein pour filets sur toutes les vis avant la pose Serrez bien les vis 1 En utilisant la clé hex fournie retirez la vis de retenue du boîtier au bas du clavier 2 Utilisez le gabarit de perçage et percez les trous nécessaires Pour un montage en applique percez les 4 trous B selon l illustration ci dessous pour un montage en rangée simple percez les 2 trous A selon l illustration ci d...

Page 8: ... à celui mentionné à l étape 1a avec le bon nombre de chiffres par ex si la longueur du code d administration est changée à 6 chiffres le code d administration par défaut passe à 123456 a Saisissez le mode configuration b Appuyez sur la touche étoile puis sur 9 La DEL de mode clignote rouge c Appuyez sur 0 puis sur 4 Un bip court retentit La DEL de mode passe au rouge d Entrez la longueur du code ...

Page 9: ... nombre à 3 chiffres 000 999 pour paramétrer l emplacement électronique du code d utilisateur de la zone 1 La DEL reste rouge et un bip court retentit après la saisie du nombre à 3 chiffres e Saisissez le nouveau code d utilisateur Le code d utilisateur doit être de la même longueur que celle du code d administration Un long bip retentit Le code d utilisateur a été ajouté avec succès Le nouveau co...

Page 10: ...ur 6 La DEL de mode clignote rouge c Appuyez sur 0 puis sur 2 Un long bip retentit La DEL de mode passe au rouge d Appuyez à nouveau sur pour quitter le mode configuration La DEL de mode passe au vert a Pour arrêter l alarme anti sabotage saisissez le mode configuration b Appuyez sur la touche étoile puis sur 6 La DEL de mode clignote rouge c Appuyez sur 0 puis sur 1 Un long bip retentit La DEL de...