background image

Page 2 of 5 

 

75.5892.03 KEYPADS 20171013

1 Red (power +)

2 Black (power ground)

3 Brown (door magnet)

4 Orange (zone 1 exit button)

5 Yellow (zone 2 exit button)

6 Green (exit button – COM)

7 White (NO)

8 Pink (COM)

9 Aqua (NC)

10 Blue (NO)

11 Purple (COM)

12 Gray (NC)

8”
0.5W recommended

-

+

13 Brown/White (door bell)

14 Black/White (door bell)

Shielding line

}

Input DC:  12V to 24V

Input AC:  12V to 24V

Shield ground

Zone 1 

UNLOCK

(dry)

Zone 2 

UNLOCK

(dry)

10KEYPADU

10KEYPADU / 10KEYPADUSL

10KEYPADUSL

C

A

A

Page 2 of 5 

 

75.5892.03 KEYPADS 20171013

5   Installation 

 Mechanical & Electrical

Installation

Wiring

CAUTION: Do not damage 

the tamper sensor.

4   Installation Notes

•  Handle the equipment with care.
•  Add threadlocker to all screws before installing.
•  Firmly tighten screws.

1. Using the supplied hex key, remove the backcase screw from the keypad bottom.
2. Use the drilling template and drill required holes. For surface mounting, drill the 4 holes marked as B in the installation image 

below; for single gang box mounting, drill the 2 holes marked as A in the installation image below. 

3. Mount backcase on the wall with provided screws. Make sure to pull keypad cable through the center hole (marked C, below). 

Keep keypad horizontal to the floor. 

4. Connect the wires based on the following wiring diagram. 
5. Mount keypad to the back cover by using the provided screws.

Summary of Contents for 10KEYPADU

Page 1: ...nds Output 2 relays free of potential change over contact Max contact voltage 42 VAC VDC Max contact current 1 A resistive Max switching power 30 W VDC 48 VA VAC Cable length 3 ft Operating temperature 22 158 F Operating humidity 0 95 non condensing IP rating IP66 waterproof and dustproof Dimension 10KEYPADU 3 0 W x 4 7 H x 0 9 D 76 mm x 120 mm x 22 mm 10KEYPADUSL 1 7 W x 5 9 H x 0 95 D 44 mm x 15...

Page 2: ...on Wiring CAUTION Do not damage the tamper sensor 4 Installation Notes Handle the equipment with care Add threadlocker to all screws before installing Firmly tighten screws 1 Using the supplied hex key remove the backcase screw from the keypad bottom 2 Use the drilling template and drill required holes For surface mounting drill the 4 holes marked as B in the installation image below for single ga...

Page 3: ...onsiting of the correct amount of digits e g if the admin code length is changed to 6 digits the admin code defaults to 123456 a Enter setup mode b Press the star key and then 9 Mode LED will flash red c Press 0 and then 4 A short beep will sound Mode LED will turn red d Enter the length of the admin code in digits ranging from 2 to 6 2 is the minimum code length and 6 is the maximum one beep admi...

Page 4: ...LED will turn red d Enter a 3 digit number 000 999 to set the electronic location for the zone 1 user code LED remains red and a a short beep will sound after entering the 3 digit number e Enter the new user code The user code must be the same length as the admin code A long beep will sound User code is successfully added The new code will replace the existing code stored in the same location f Re...

Page 5: ...o turn on the tamper alarm feature enter setup mode b Press the star key and then 6 Mode LED will flash red c Press 0 and then 2 A long beep will sound Mode LED will turn red d Press again to exit setup mode Mode LED turns green a To turn off the tamper alarm enter setup mode b Press the star key and then 6 Mode LED will flash red c Press 0 and then 1 A long beep will sound Mode LED will turn red ...

Page 6: ...urs Durée du double verrouillage 0 99 secondes Sortie 2 relais contact sans potentiel Tension de contact max 42 VCA VCC Courant de contact max 1 A résistant Puissance de commutation max 30 W VCC 48 VA VCA Longueur du câble 3 pi Température de fonctionnement 22 158 F Humidité en fonctionnement 0 95 sans condensation Indice de protection IP66 résistance à l eau et à la poussière Dimension 10KEYPADU ...

Page 7: ...ez de l enduit frein pour filets sur toutes les vis avant la pose Serrez bien les vis 1 En utilisant la clé hex fournie retirez la vis de retenue du boîtier au bas du clavier 2 Utilisez le gabarit de perçage et percez les trous nécessaires Pour un montage en applique percez les 4 trous B selon l illustration ci dessous pour un montage en rangée simple percez les 2 trous A selon l illustration ci d...

Page 8: ... à celui mentionné à l étape 1a avec le bon nombre de chiffres par ex si la longueur du code d administration est changée à 6 chiffres le code d administration par défaut passe à 123456 a Saisissez le mode configuration b Appuyez sur la touche étoile puis sur 9 La DEL de mode clignote rouge c Appuyez sur 0 puis sur 4 Un bip court retentit La DEL de mode passe au rouge d Entrez la longueur du code ...

Page 9: ... nombre à 3 chiffres 000 999 pour paramétrer l emplacement électronique du code d utilisateur de la zone 1 La DEL reste rouge et un bip court retentit après la saisie du nombre à 3 chiffres e Saisissez le nouveau code d utilisateur Le code d utilisateur doit être de la même longueur que celle du code d administration Un long bip retentit Le code d utilisateur a été ajouté avec succès Le nouveau co...

Page 10: ...ur 6 La DEL de mode clignote rouge c Appuyez sur 0 puis sur 2 Un long bip retentit La DEL de mode passe au rouge d Appuyez à nouveau sur pour quitter le mode configuration La DEL de mode passe au vert a Pour arrêter l alarme anti sabotage saisissez le mode configuration b Appuyez sur la touche étoile puis sur 6 La DEL de mode clignote rouge c Appuyez sur 0 puis sur 1 Un long bip retentit La DEL de...

Reviews: