background image

10

11

CAUTION

Excessively high operating speeds increase risk of injury and damage to 
water pump.

Excessively low speeds impose a heavy load.
• DO NOT tamper with the governed speed.
• DO NOT modify the water pump.
• DO NOT allow unqualified persons or children to operate or service
  water pump.

NOTICE

Improper treatment of water pump can damage it and shorten its life.
• If you have questions about intended use, ask dealer or contact

nearest authorized dealer.

• Be sure pump chamber is filled with water before starting the engine.
  Never run pump without priming.
• Use a non-collapseable hose on the suction side of the hose.
• Use water pump only for intended uses.
• Pumping sea water, beverages, acids, chemical solutions, or any other
  liquid that promotes corrosion can damage the pump.
• Ensure all connections are air tight.
• DO NOT obstruct the suction or discharge hose in any way.
• NEVER operate pump without strainer basket connected to end of
  suction hose.  
• NEVER allow vehicles to drive over hoses. If a hose must be

positioned across a roadway, use planking on each side of hose to
allow vehicles to pass over without obstructing or collapsing hose.

• Anchor pump to avoid equipment movement.
• Keep equipment away from edge of river or lake where it could cause

the bank to collapse.

• DO NOT insert any objects through cooling slots.
• NEVER operate units with broken or missing parts, or without

protective housing or covers.

• DO NOT by-pass any safety device on this machine.
• NEVER move machine by pulling on hoses. Use frame on unit.
• Check fuel system for leaks or signs of deterioration, such as chafed

or spongy hose, loose or missing clamps, or damaged tank or cap.
Correct all defects before operating water pump.

SAFETY

Your unit may differ from the model shown 

below. For specific model information, please 

visit our website:

 BEPOWEREQUIPMENT.COM 

1. Fuel Tank 

Fill tank with regular unleaded fuel. Always leave room for fuel

expansion.

2. Priming Plug

 Fill pump with water here to prime pump before starting.

3. Discharge Outlet 

Connect discharge hose here.

4. Choke Lever 

Prepares a cold engine for starting.

5. Air Cleaner 

Protects engine by filtering dust and debris out of intake air.

6. Recoil Starter 

Used for starting the engine manually.

7. Engine Speed Lever 

Used to adjust engine speed to control pump output.

8. On/Off Switch 

Set this switch to “On” before using recoil starter. Set switch to

“Off” to stop a running engine.

9. Oil Drain 

Drain engine oil here.

10. Oil Fill 

Check and add engine oil here.

11. Suction Inlet 

Connect reinforced suction hose here.

12. Water Drain Plug 

Remove to drain water from pump

 

and flush internal

components with clean water.

13. Pump Chamber 

Be sure to fill with water before starting.

14. Fuel Shutoff Valve 

Used to turn fuel supply on and off to engine.

Item Not Shown:

Strainer Basket  

Used to limit passage of abrasive materials into the pump.

WATER PUMP COMPONENTS

1.

2.

3.

12.

11.

7.

6.

13.

14.

9.

11.

4.

10.

8.

Summary of Contents for Wildland WS1525SKID

Page 1: ...FIRE PUMP WS1525H WS1525SKID WS1565H WS1565HP WS1565FC USER MANUAL Fire Fighting Water Pumps WILDLAND S E R I E S...

Page 2: ...ing Hose to Pump 13 Attaching Suction Hose to Strainer Basket 13 Connecting Discharge Hose Operation 14 What is Head 15 Moving the Water Pump to a Safe Location 15 Priming the Water Pump 16 Placing th...

Page 3: ...fety requirements to the operating functions of your machine You can refer back to the manual at any time to help troubleshoot any specific operating functions so store it with the machine at all time...

Page 4: ...ison gas Breathing carbon monoxide can cause headaches fatigue dizziness vomiting confusion seizures nau sea fainting or death Operate water pump ONLY outdoors Keep exhaust gas from entering a confine...

Page 5: ...oring Fuel or Equipment with Fuel in Tank Store away from furnaces stoves water heaters clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel v...

Page 6: ...issing parts or without protective housing or covers DO NOT by pass any safety device on this machine NEVER move machine by pulling on hoses Use frame on unit Check fuel system for leaks or signs of d...

Page 7: ...sch 1 2 3 C A B Your water pump requires some set up and is ready for use after it has been properly serviced with the recommended oil and fuel Attach Suction Hose to Strainer Basket 1 Slide hose clam...

Page 8: ...ng the discharge head Suction head is a maximum of 25 feet and discharge head should be a maximum of 81 feet Total head can not be more than 106 feet as shown on next page Move Water Pump to Safe Oper...

Page 9: ...d pump chamber is primed 3 Turn fuel valve 1 to On position The fuel valve handle will be vertical pointing toward the ground 4 Push on off switch 2 to On position 5 Move engine speed lever 3 to Fast...

Page 10: ...o cool before touching Keep at least 5 feet 1 5 m of clearance on all sides of pressure washer including overhead Pump output is controlled by adjusting engine speed Moving the engine speed lever in t...

Page 11: ...need assistance with the assembly or operation of your Water Pump please call Si vous avez besoin d assistance avec l assemblage ou l op ration de de cette pompe eau s il vous plait appelez le 1 866 8...

Page 12: ...ur sur la position RUN IMPORTANT Cela peut prendre plusieurs minutes pour que la pompe commence pomper l eau ATTENTION Le contact avec le silencieux peut r sulter en de s rieus es br lures La chaleur...

Page 13: ...dans la source d eau Placer le panier filtre dans l eau pomper Le panier doit tre compl te ment submerg AVIS Une mauvaise utilisation de la pompe eau peut l endommager et rac courcir sa dur e de vie...

Page 14: ...e pomper au fond d un r servoir La pression de t te totale est la somme de la valeur de la pression de t te de la succion et celle du refoulement mesure que la colonne d eau augmente la performance di...

Page 15: ...ile et l essence recommand Raccorder le tuyau de succion la pompe 1 Glissez le collier de serrage A Sur le bout du tuyau B Glissez le tuyau de succion sur raccord cannel du tuyau C Serrez le collier f...

Page 16: ...s d aucune mani re la pompe eau Ne laissez pas des gens non qualifi ou des enfants utiliser ou desservir la pompe eau AVIS Une mauvaise utilisation de la pompe eau peut l endommager et raccourcir sa d...

Page 17: ...LES DE S CURIT S 8 ATTENTION Fuel and its vapors are extremely flammable and explosive Fire or explosion can cause severe burns or death Remplissage ou vidange de l essence Arr tez la pompe eau et lai...

Page 18: ...e puisse pas entrer en contact avec la bougie d allumage Contr le de la bougie d allumage du moteur Utilisez un testeur de bougie approuv Ne pas tester le moteur si la bougie a t enlev e R GLES DE S C...

Page 19: ...er de cet outil de r f rence aussi souvent que n cessaire pour s assurer d une s curit ad quate et d une prise en compte de toutes vos pr occupations La lecture en profondeur du manuel d utilisation v...

Page 20: ...ge 12 Raccorder le tuyau de succion la pompe 12 Fixer le boyau de succion au panier filtre 12 Raccorder le tuyau de d charge Mode d emploi 14 Qu est que la pression de t te 14 Installer la pompe eau d...

Page 21: ...POMPE INCENDIE WS1525H WS1525SKID WS1565H WS1565HP WS1565FC USER MANUAL Fire Fighting Water Pumps WILDLAND S E R I E S...

Reviews: