PRE-START INSPECTION PROCEDURES
Before starting the unit, perform the following procedures:
1. Check the oil level in the pump and engine.
2. Inspect the water inlet strainer. Clean or replace if necessary. See
“Water Supply”, #2, pg 16.
3. Check all hose connections to ensure they are securely tightened. See
“Water Supply”, #3, pg. 16.
4. Inspect for system water leaks, oil leaks and fuel leaks. If a fuel leak is
found, DO NOT START UNIT! See “Risk of Explosion or Fire”, pg. 7.
Be sure that all damaged parts are replaced and that the mechanical
problems are corrected prior to operation of the unit. If you require
service, contact Customer Service.
5. Inspect high pressure hoses for kinking, cuts and leaks. If a cut or leak
is found, DO NOT USE HOSE! Replace hose before starting unit. See
“Risk of Injection” pg. 8. Be sure that all damaged parts are replaced
and that the mechanical problems are corrected prior to operation of
the unit. If you require service, contact Customer Service.
THERMAL RELIEF VALVE
To ensure the water temperature does not exceed acceptable levels,
never allow the pressure washer to operate in the bypass mode (with the
unit running and the trigger closed) for more than three minutes.
A “thermal relief valve” has been added to this unit to protect the pump.
It may begin to open and release water if the water temperature in the
pump has exceeded 140° F. This will allow fresh, cool water to enter the
system.
INSTALLATION & PREPARATION
Summary of Contents for HW3513HAD
Page 1: ...User Manual HOT WATER PRESSURE WASHER HW3513HAD BEPOWEREQUIPMENT COM...
Page 32: ...32 FLOW CHART EMF SYSTEM 46 FLOW CHART EM FLOW CHART EMF SYSTEM PARTS LIST...
Page 36: ...36 ENGINE PUMP ASSEMBLY 50 ENGINE PUMP ASSEMBLY PARTS LIST...
Page 47: ...47 BOILER ASSEMBLY 64 BOILER ASSEMBLY 850 0226 ELECTRODE GAP SETTINGS PARTS LIST...
Page 53: ...53 EMF SYSTEM 72 EMF SYSTEM 850 0403 PARTS LIST...
Page 56: ...56 WIRING DIAGRAM WIRING SCHEMATIC 76 WIRING SCHEMATIC 77 WIRING DIAGRAM PARTS LIST...
Page 59: ...59...