17
Shutting Down
PROCEDURES
1. Turn the valve on the LP cylinder clockwise to stop the flow of fuel.
2. Turn the Heater Regulator Knob to the “OFF” position, and wait at
least fifteen (15) minutes for the heater to cool.
3. Remove the heater from the LP cylinder by reversing the steps in
Connecting Heater to LP Cylinder on Page 4. Do not store the LP
cylinder with the heater still attached, or in an enclosed area.
BE SURE TO FOLLOW THE DIRECTIONS OUTLINED IN
VENTILATION.
ALWAYS INSPECT HEATER BEFORE USE AND AT LEAST
ANNUALLY BY A QUALIFIED SERVICE PERSON.
DANGER
Never bring or store a propane cylinder indoors.
CAUTION
Always keep heater out of the reach of children.
Maintenance and Storage
1. Inspect your heater before each use. Check all connections for leaks,
following the procedure outlined on Pages 4 and 5. Check the Regula-
tor Hose (dual burner models only) for any cracks, breaks or wear. If the
hose is damaged replace it with the correct manufacturers part.
2. After use, always disconnect the heater from the LP cylinder, and store
the heater separately from the tank. Be sure to close the tank valve after
use, and before storage. The LP cylinder should be stored outdoors in
accordance with chapter 5 of the Standard for Storage and Handling of
Liquefied Petroleum Gasses (ANSI/INFPA 58).
SHUTTING DOWN