background image

 

Version 0.2 

31 July 2013 

www.iHome.eu

 

Troubleshooting 

 

Frequently Asked Questions 

 

Q

: I can’t have my 

Panic Watch

 included into my Z-Wave network, what am I doing wrong? 

A

1

. Is the controller ready to include any device into the Z-Wave network? If the controller is not in  

 

Include or exclude mode, the 

Panic Watch

 will not be included or excluded. 

 

2

. The 

Panic Watch

 is already included in a Z-Wave network (check your led feedback!). Exclude the 

Panic Watch

 and try again. 

 

Q: 

I have configured a value but when I request it, it is not changed? 

A: 

It is mandatory

 

that the

 

correct size is used while configure a parameter; go to the documentation about 

the configuration command class to check if the right size is used during configuration. If the wrong size is used 
the frame is ignored totally.  

 
Q: 

I have configured a new value and when I request it the correct value is returned but the behavior is still the 

same? 

A:

 Some configuration parameters have limits of what they can do, go to the documentation about 

configuration to check if the value of the configured parameter is out off limit. 
 

Q

: how to force a wakeup notification? 

A: keep the pushbutton pressed for more than 18 seconds. 

Summary of Contents for Panic Watch EU

Page 1: ... to a Z Wave based alarm device Use 1 Before use the Panic Watch should be included into a Z Wave network and associated 2 You can Test you Panic Watch by pressing the button for 1sec untill the led is turned on press time is configurable 3 Don t forget to update and syncronize your rules in the Internet Gateway Include or Exclude in Z Wave network 1 1 Press and hold the SOS Push Button until the ...

Page 2: ...tor light gives various statuses of the device as follows 1 Ready for learn mode indicator light blinks every second 2 Learn in progress add indicator light 2 times every second 3 Learn in progress remove indicator light 3 times every 1 5 second 4 Learn mode success indicator light is on for one second 5 RF message send success indicator light is on for one second 6 RF message send failed indicato...

Page 3: ... initiator is used by Primary Controllers to exclude nodes from the network When the exclude initiator and a slave initiator are activated simultaneously it will result in the slave being excluded from the network and reset to Node ID zero Even if the slave was not part of the network it will still be reset by this action Z Wave compatibility Because this is a Z Wave device it means it can co oper...

Page 4: ...tion The time that the panic pushbutton must be pressed before a panic message is sent out to the controller Default 0x64 10ms 1sec Size 1 byte Param1 if 0x00 send directly the panic message when pressed If 0x01 0xFF send a panic message after you keep holding the button pressed for this value x 10ms 3 Min led feedback time panic Description Minimum time that led feedback is shown after a panic me...

Page 5: ...st and report battery levels for a given device When battery level is lower then 20 the Panic Watch will send a battery warning value 255 after every wake up notification A battery get will report the actual value even if below 20 When the batteries are placed a unsolicited battery report is sent when included class 0x84 COMMAND_CLASS_WAKE_UP The Wake Up Command Class is used at battery operated d...

Page 6: ...d hold the button the duration to hold depends on the configured values parameter 2 When double pressed quickly within 500 msec double press the button This mode can be configured with the following frame CONFIGURATION_SET Parameter 0x04 Size 0x01 can t be different from 1 Value 0x00 Below figure shows an overview of the Z Wave frames values and association groups When single pressed and hold ALAR...

Page 7: ...old depends on the configured values parameter 2 When double pressed quickly within 500 msec double press the button This mode can be configured with the following frame CONFIGURATION_SET Parameter 0x04 Size 0x01 can t be different from 1 Value 0x01 0xFF Below figure shows an overview of the Z Wave frames values and association groups When single pressed and hold BASIC_SET Value 0xFF To assocation...

Page 8: ...guration parameter is changed back to the default value Value 0xAA Devices still has all his factory settings This are only configuration parameters wake up interval can be changed Always awake mode The always awake mode is used to request different values from the device e g version and manufacturer specific The always awake mode can be activated by CONFIGURATION_SET Parameter 0x05 Size 0x01 can ...

Page 9: ...a value but when I request it it is not changed A It is mandatory that the correct size is used while configure a parameter go to the documentation about the configuration command class to check if the right size is used during configuration If the wrong size is used the frame is ignored totally Q I have configured a new value and when I request it the correct value is returned but the behavior is...

Reviews: