class: 0x30 COMMAND_CLASS_SENSOR_BINARY 
class: 0x85 COMMAND_CLASS_ASSOCIATION 
class: 0x84 COMMAND_CLASS_WAKE_UP 
class: 0x86 COMMAND_CLASS_VERSION 
class: 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC 
class: 0x70 COMMAND_CLASS_CONFIGURATION 
class: 0x80 COMMAND_CLASS_BATTERY 
class: 0x71   COMMAND_CLASS_ALARM 
class: 0xEF COMMAND_CLASS_MARK 
class: 0x20 COMMAND_CLASS_BASIC 

 

Not listening Routing SLAVE 

This Z-Wave product will be used as routing slave. Slave nodes are nodes in a Z-Wave network that receive 
commands and perform actions based on the command. This device will always be in sleep mode because it 
works on batteries. In sleep mode the device is not active listening, the device will wake up according to the 
wakeup command class.  
 

Include Initiator 

The include initiator is used when Primary and Inclusion Controllers include nodes into the network. When 
both the include initiator have been activated simultaneously the new node will be included to the network (if 
the node was not included previously).  

Exclude Initiator 

The exclude initiator is used by Primary Controllers to exclude nodes from the network. When the exclude 
initiator and a slave initiator are activated simultaneously, it will result in the slave being excluded from the 
network (and reset to Node ID zero). Even if the slave was not part of the network it will still be reset by this 
action.  

Z-Wave compatibility 

Because this is a Z-Wave device, it means it can co-operate with other Z-Wave devices of other manufacturers. 
It can co-exist in a Z-Wave network existing with product from other manufacturers.  

Hops & Retries 

The Z-Wave range has a range of up to 30 meters in line of sight. This signal is not limited to the 30 meter 
range due to routing the Z-Wave message to other nodes in the network. This way the range of the Z-Wave 
network can be expanded to 150 meters indoors (limit of 4 hops).  

 
class: 0x20 COMMAND_CLASS_BASIC 

When a button is pressed for 1sec a basic set frame with the value 255 is sent to the associated nodes.  
 
The supporting role of the basic command class is mapped to the sensor binary command class. 

 
class: 0x25 COMMAND_CLASS_SENSOR_BINARY 

The Sensor Binary Command Class can be used to check the status of the 

Panic Watch

 (triggered or idle).  

Where “255” is triggered, and “0” is idle. 
 

class: 0x86 COMMAND_CLASS_VERSION 

Summary of Contents for Panic Watch EU

Page 1: ... to a Z Wave based alarm device Use 1 Before use the Panic Watch should be included into a Z Wave network and associated 2 You can Test you Panic Watch by pressing the button for 1sec untill the led is turned on press time is configurable 3 Don t forget to update and syncronize your rules in the Internet Gateway Include or Exclude in Z Wave network 1 1 Press and hold the SOS Push Button until the ...

Page 2: ...tor light gives various statuses of the device as follows 1 Ready for learn mode indicator light blinks every second 2 Learn in progress add indicator light 2 times every second 3 Learn in progress remove indicator light 3 times every 1 5 second 4 Learn mode success indicator light is on for one second 5 RF message send success indicator light is on for one second 6 RF message send failed indicato...

Page 3: ... initiator is used by Primary Controllers to exclude nodes from the network When the exclude initiator and a slave initiator are activated simultaneously it will result in the slave being excluded from the network and reset to Node ID zero Even if the slave was not part of the network it will still be reset by this action Z Wave compatibility Because this is a Z Wave device it means it can co oper...

Page 4: ...tion The time that the panic pushbutton must be pressed before a panic message is sent out to the controller Default 0x64 10ms 1sec Size 1 byte Param1 if 0x00 send directly the panic message when pressed If 0x01 0xFF send a panic message after you keep holding the button pressed for this value x 10ms 3 Min led feedback time panic Description Minimum time that led feedback is shown after a panic me...

Page 5: ...st and report battery levels for a given device When battery level is lower then 20 the Panic Watch will send a battery warning value 255 after every wake up notification A battery get will report the actual value even if below 20 When the batteries are placed a unsolicited battery report is sent when included class 0x84 COMMAND_CLASS_WAKE_UP The Wake Up Command Class is used at battery operated d...

Page 6: ...d hold the button the duration to hold depends on the configured values parameter 2 When double pressed quickly within 500 msec double press the button This mode can be configured with the following frame CONFIGURATION_SET Parameter 0x04 Size 0x01 can t be different from 1 Value 0x00 Below figure shows an overview of the Z Wave frames values and association groups When single pressed and hold ALAR...

Page 7: ...old depends on the configured values parameter 2 When double pressed quickly within 500 msec double press the button This mode can be configured with the following frame CONFIGURATION_SET Parameter 0x04 Size 0x01 can t be different from 1 Value 0x01 0xFF Below figure shows an overview of the Z Wave frames values and association groups When single pressed and hold BASIC_SET Value 0xFF To assocation...

Page 8: ...guration parameter is changed back to the default value Value 0xAA Devices still has all his factory settings This are only configuration parameters wake up interval can be changed Always awake mode The always awake mode is used to request different values from the device e g version and manufacturer specific The always awake mode can be activated by CONFIGURATION_SET Parameter 0x05 Size 0x01 can ...

Page 9: ...a value but when I request it it is not changed A It is mandatory that the correct size is used while configure a parameter go to the documentation about the configuration command class to check if the right size is used during configuration If the wrong size is used the frame is ignored totally Q I have configured a new value and when I request it the correct value is returned but the behavior is...

Reviews: