WORKING PRINCIPLE

57GUNMOD

The measurement system is based on the bore of the oil meter which contains two elliptical gears. The gear will

rotate when the oil flows through the bore of gun. The flow of oil is the same at each rotation. When gears 

rotate, the generated pulse signal will be recorded to processes by a microprocessor. The magnetic coupling 

function between gear with magnet and magnetic switch out of the bore of gun not only guarantees the bore 

of gun leak-proof quality, but also ensures the pulse which produced by gear rotation will transmit to the 

microprocessor on circuit board. The microprocessor has been converted the pulse into the volume of fuel by 

adjusting parameters properly and displayed on the screen.

The measurement grease gun is adjusted with 10W-40 oil before leaving the factory. Each one has primary 

parameter. It can be adjusted on spot and would maintain the best function that can be used to measure the 

volume of oil if needs. 

Please adjust on spot if operators want to measure precisely as the oil viscosity of factory may be different.

For different customers, due to the use of oil specifications are not the same, usually before use, for the oil flow

corrections in order to achieve the actual amount of oil and the meter display value of the same or close to

(reduce error).

Usually, when the oil meter was equipped with battery (automatically reads the parameters), it will show some 

data on the screen, if the shown data is Error (Err), Please reset the data according to the below instructions.

Operation Methods:

1. First enter into the operation status, then press button “Total”.

2. Still into the operation status, press the button “Reset” for 2 seconds, then the flow meter will get into the 

    Setting Status.

3. Press the “Reset” button for another 2 seconds, now the flow meter will show new data on the screen.

4. The current display is clear and the cumulative is clear, for example: the initial image is above 0.75 and 2.5 

     as cumulative data. As the pictures below:

Picture A: 0.75 means current filling volume, while the number 2.5 means till now the total filling volume is 2.5L.

Picture B: means the current filling data is 0.00

ADJUST FLOW METER METHODS AND OPERATION INSTRUCTIONS

Summary of Contents for 57GUNMOD

Page 1: ...57GUNMOD Digital Control Valve Operations Parts Manual Purchase Date Dealer...

Page 2: ...power down mode if it does not work c It has fixed memory to save total oil amount data it can preserve the total amount and primary parameters even if the power interrupts completely long time d Set...

Page 3: ...ant to measure precisely as the oil viscosity of factory may be different For different customers due to the use of oil specifications are not the same usually before use for the oil flow corrections...

Page 4: ...omatically enter the running state now you can start to work 6 When the battery is getting low the flow meter will show L1 L0 flashing this means the you need to replace the battery 7 After 30 seconds...

Page 5: ...tton the first digit flicker and then determined by Total so the number third is back until a bit 0 digital flicker press Reset key the digits change until the required oil press Total to confirm and...

Page 6: ...le into other codes 005374 at the same time can also be adjusted according to the same method until the actual injection quantity and injection quantity display basically the same to determine the par...

Page 7: ...nternal import sealing ring of mouth can extend service life Outlet oil hose is made of steel elbow pipe and hose kits and can be available on users 3 Operation on digital measurement oil meter gun Co...

Page 8: ...where the left gear loads with the magnet and it forward down with the magnet shown in right picture The left gear must be installed vertically with the right gear Make sure the gear turns freely bef...

Page 9: ...CONT 57GUNMOD TROUBLE SHOOTING GUIDE PROBLEM POSSIBLE CAUSE POSSIBLE REMEDY The flux diminish or not leave the oil Clean the filter Filter jamming The flux is normal but has not shown the measurement...

Page 10: ...ould be calibrated or after using for one month or change another type of oil Any Loss caused by your improper operation or not caused in accordance with our instructions our company will not bear the...