BC Biomedical ENDOCHECK Test system User Manual Download Page 4

 

 

II.     SPECIFICATIONS 

 

BC Biomedical Model 401025 Light Meter 

 
Light level units & ranges 

Lux: 0-2,000, 0-20,000, & 0-50,000 

    Foot-Candles: 

0-200, 

0-2,000, 

0-5,000 

 
Resolution 

 

 

.1 FC or 1 Lux 

 
Accuracy 

 

 

+/- 5% of full scale 

 
Detector 

Precision photo diode with color-correction 
filter; cosine/color corrected 

 
Analog output  

 

1 mA per readout digit 

 
Dimensions 

6.4” x 2.8” x 1.2” (163mmx7mm0x30mm); 
9 oz. (220g) 

 
Power 

   9 

volt 

battery 

(included) 

 
 

BC Biomedical EndoProjector

 

 
Construction & Type   

Stainless steel body and precision glass optics 

 
Projection Magnification 

Approximately 10X 

 
Size   

 

 

0.75” diameter x 1.375” long 

 
Light cable compatibility 

Adapters included to fit most popular 
endoscopy light cables 

 
 

BC Biomedical EndoCheck

 Light Meter Adapter 

 
Construction 

  Plated 

steel 

 
Light cable compatibility  

Via EndoProjector™ 

 

 

Overall system 

 
Warranty on all 

 

1 year from date of purchase 

 
Accessories Included 

  Hard carrying case 

 User 

manual 

 
 
 
 
 
 

This system does not 

include a light source or 

fiber cable. It is intended 

to be used with the 

customer’s light sources 

and fiber cables.

Summary of Contents for ENDOCHECK Test system

Page 1: ...User Manual ENDOCHECK Test System...

Page 2: ...CONTENTS I INTRODUCTION 2 II SPECIFICATIONS 3 III RECEIPT INSPECTION RETURN 4 IV USE OF THE ENDOCHECK TEST SYSTEM 5 V APPLICATIONS 6 VI WARRANTY 7 VII TECHNICAL SUPPORT 7...

Page 3: ...cal component that yields an approximately 10X magnification of the light signal coming out of the fiber cable The image when displayed on a wall or other flat surface generally allows the individual...

Page 4: ...cal EndoProjector Construction Type Stainless steel body and precision glass optics Projection Magnification Approximately 10X Size 0 75 diameter x 1 375 long Light cable compatibility Adapters includ...

Page 5: ...ument and provide the model and serial numbers If possible use the original packaging material for return shipping Otherwise repack the unit using a reinforced cardboard box strong enough to carry the...

Page 6: ...t to allow counting of individual fibers or to make a quantitative assessment of cable quality It allows a quick visual and intuitive analysis of relative cable quality 7 If a quantitative analysis of...

Page 7: ...ected to a specific light source at a predetermined intensity setting you may choose to replace those fiber cables whenever they degrade to 80 of new light throughput or 8 000 lux Note These lux readi...

Page 8: ...ther form of guarantee concerning the EndoCheck Test System other than this guarantee Some jurisdictions do not allow disclaimers of expressed or implied warranties in certain transactions therefore t...

Reviews: